{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:6355"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:6355","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"nEUCLID: a new homodyne interferometer with space applications","abstract":"The objective of this project was to design a low-mass, low-power interferometer to be used for space applications. It had to be capable of remaining tilt-immune whilst working at a distance of at least 1 m. This thesis describes the design and subsequent building of a 1550 run homodyne interferometer. Known as nEUCLID, it has a working distance of 660 mm and a working range of± 120 mm. These large distances are made possible by the novel cat's eye design within the interferometer, which also allows tilt immunity of± 0.35° of the target mirror (at the sweet plane). The thesis explains in detail the theory and design of the cat's eye, known as a PCE in the text. The interferometer, nEUCLID, has a sensitivity of 420 pm/√Hz, at 1 Hz in air, tested at the working distance of the current design. It has a mass of 2 kg and an overall power of 1.8 W. Both of these values are due to using standard, off-the-shelf components in the design, and could be reduced with further development. Within this thesis ground-based and space-based applications for nEUCLID within the space industry are discussed and compared with existing technologies.","abstract_html":"The objective of this project was to design a low-mass, low-power interferometer to be used for space applications. It had to be capable of remaining tilt-immune whilst working at a distance of at least 1 m. This thesis describes the design and subsequent building of a 1550 run homodyne interferometer. Known as nEUCLID, it has a working distance of 660 mm and a working range of± 120 mm. These large distances are made possible by the novel cat&#x27;s eye design within the interferometer, which also allows tilt immunity of± 0.35° of the target mirror (at the sweet plane). The thesis explains in detail the theory and design of the cat&#x27;s eye, known as a PCE in the text. The interferometer, nEUCLID, has a sensitivity of 420 pm/√Hz, at 1 Hz in air, tested at the working distance of the current design. It has a mass of 2 kg and an overall power of 1.8 W. Both of these values are due to using standard, off-the-shelf components in the design, and could be reduced with further development. Within this thesis ground-based and space-based applications for nEUCLID within the space industry are discussed and compared with existing technologies.","abstract_has_math":false,"creators":["Bradshaw, Miranda"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-12","date_published":"2015-12","updated_at":"2026-11-19T09:28:49Z","subjects":["QC Physics"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/6355/1/Bradshaw15PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A6355","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Bradshaw, Miranda"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2015-12"]},{"key":"dc:date.issued","label":"Date","values":["2015-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Physics and Astronomy"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/6355/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["QC Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/6355/1/Bradshaw15PhD.pdf","http://etheses.bham.ac.uk//id/eprint/6355/5/Decl_IS_Bradshaw15PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this project was to design a low-mass, low-power interferometer to be used for space applications. It had to be capable of remaining tilt-immune whilst working at a distance of at least 1 m. This thesis describes the design and subsequent building of a 1550 run homodyne interferometer. Known as nEUCLID, it has a working distance of 660 mm and a working range of± 120 mm. These large distances are made possible by the novel cat's eye design within the interferometer, which also allows tilt immunity of± 0.35° of the target mirror (at the sweet plane). The thesis explains in detail the theory and design of the cat's eye, known as a PCE in the text. The interferometer, nEUCLID, has a sensitivity of 420 pm/√Hz, at 1 Hz in air, tested at the working distance of the current design. It has a mass of 2 kg and an overall power of 1.8 W. Both of these values are due to using standard, off-the-shelf components in the design, and could be reduced with further development. Within this thesis ground-based and space-based applications for nEUCLID within the space industry are discussed and compared with existing technologies."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["nEUCLID: a new homodyne interferometer with space applications"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Bradshaw, Miranda"],"dc:date":["2015-12"],"dc:date.issued":["2015-12"],"dc:description.abstract":["The objective of this project was to design a low-mass, low-power interferometer to be used for space applications. It had to be capable of remaining tilt-immune whilst working at a distance of at least 1 m. This thesis describes the design and subsequent building of a 1550 run homodyne interferometer. Known as nEUCLID, it has a working distance of 660 mm and a working range of± 120 mm. These large distances are made possible by the novel cat's eye design within the interferometer, which also allows tilt immunity of± 0.35° of the target mirror (at the sweet plane). The thesis explains in detail the theory and design of the cat's eye, known as a PCE in the text. The interferometer, nEUCLID, has a sensitivity of 420 pm/√Hz, at 1 Hz in air, tested at the working distance of the current design. It has a mass of 2 kg and an overall power of 1.8 W. Both of these values are due to using standard, off-the-shelf components in the design, and could be reduced with further development. Within this thesis ground-based and space-based applications for nEUCLID within the space industry are discussed and compared with existing technologies."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/6355/1/Bradshaw15PhD.pdf","http://etheses.bham.ac.uk//id/eprint/6355/5/Decl_IS_Bradshaw15PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Physics and Astronomy"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/6355/"],"dc:subject":["QC Physics"],"dcterms:accessrights":["public","staffonly"],"dc:title":["nEUCLID: a new homodyne interferometer with space applications"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:28:49Z"}