{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:7194"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:7194","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"An investigation into the importance of T2 relaxation and echo time choice for accurate metabolite biomarker quantification","abstract":"Metabolite concentrations are fundamental biomarkers of disease. With increasing interest in personalised medicine, this work assessed the accuracy of non-invasive metabolite quantification with magnetic resonance spectroscopy (MRS) using a combination of simulations, phantom and in vivo data. No optimal echo time (TE) was found for measuring a range of key metabolites with quantification accuracy generally influenced more by data quality than TE choice. The T2 relaxation times of water and metabolites with MRS dominated by a singlet could be estimated using 2 TEs and were found to be significantly different in paediatric brain tumours compared with normal brain, varying between tumour types. The T2 relaxation times of paediatric brain tumours were significantly shorter at 3T compared with 1.5T. Metabolite concentrations for individual patients were most affected by changes in the T2 relaxation time of water which is quick to measure. A clinical JPRESS protocol was developed which aids assignment of overlapping metabolites using changes of MRS with TE. Overall, measurement of MRS with a short TE reduces inaccuracies associated with variability in metabolite T2 and does not tend to lead to worse quantification of overlapping resonances. Further improvements in concentration accuracy can be obtained by measuring case-specific water T2.","abstract_html":"Metabolite concentrations are fundamental biomarkers of disease. With increasing interest in personalised medicine, this work assessed the accuracy of non-invasive metabolite quantification with magnetic resonance spectroscopy (MRS) using a combination of simulations, phantom and in vivo data. No optimal echo time (TE) was found for measuring a range of key metabolites with quantification accuracy generally influenced more by data quality than TE choice. The T2 relaxation times of water and metabolites with MRS dominated by a singlet could be estimated using 2 TEs and were found to be significantly different in paediatric brain tumours compared with normal brain, varying between tumour types. The T2 relaxation times of paediatric brain tumours were significantly shorter at 3T compared with 1.5T. Metabolite concentrations for individual patients were most affected by changes in the T2 relaxation time of water which is quick to measure. A clinical JPRESS protocol was developed which aids assignment of overlapping metabolites using changes of MRS with TE. Overall, measurement of MRS with a short TE reduces inaccuracies associated with variability in metabolite T2 and does not tend to lead to worse quantification of overlapping resonances. Further improvements in concentration accuracy can be obtained by measuring case-specific water T2.","abstract_has_math":false,"creators":["Carlin, Dominic Alexander"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-07","date_published":"2017-07","updated_at":"2026-11-19T09:29:14Z","subjects":["RB Pathology","RC0254 Neoplasms. Tumors. Oncology (including Cancer)","RJ Pediatrics"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/7194/1/Carlin17PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A7194","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["other","nihr"]},{"key":"dc:creator","label":"Author","values":["Carlin, Dominic Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-07"]},{"key":"dc:date.issued","label":"Date","values":["2017-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Medical & Dental Sciences","Institute of Cancer and Genomic Sciences"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/7194/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["RB Pathology","RC0254 Neoplasms. Tumors. Oncology (including Cancer)","RJ Pediatrics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/7194/1/Carlin17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7194/2/Decl_IS_Carlin17PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Metabolite concentrations are fundamental biomarkers of disease. With increasing interest in personalised medicine, this work assessed the accuracy of non-invasive metabolite quantification with magnetic resonance spectroscopy (MRS) using a combination of simulations, phantom and in vivo data. No optimal echo time (TE) was found for measuring a range of key metabolites with quantification accuracy generally influenced more by data quality than TE choice. The T2 relaxation times of water and metabolites with MRS dominated by a singlet could be estimated using 2 TEs and were found to be significantly different in paediatric brain tumours compared with normal brain, varying between tumour types. The T2 relaxation times of paediatric brain tumours were significantly shorter at 3T compared with 1.5T. Metabolite concentrations for individual patients were most affected by changes in the T2 relaxation time of water which is quick to measure. A clinical JPRESS protocol was developed which aids assignment of overlapping metabolites using changes of MRS with TE. Overall, measurement of MRS with a short TE reduces inaccuracies associated with variability in metabolite T2 and does not tend to lead to worse quantification of overlapping resonances. Further improvements in concentration accuracy can be obtained by measuring case-specific water T2."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["An investigation into the importance of T2 relaxation and echo time choice for accurate metabolite biomarker quantification"]}]}],"canonical_facts":{"dc:contributor.sponsor":["other","nihr"],"dc:creator":["Carlin, Dominic Alexander"],"dc:date":["2017-07"],"dc:date.issued":["2017-07"],"dc:description.abstract":["Metabolite concentrations are fundamental biomarkers of disease. With increasing interest in personalised medicine, this work assessed the accuracy of non-invasive metabolite quantification with magnetic resonance spectroscopy (MRS) using a combination of simulations, phantom and in vivo data. No optimal echo time (TE) was found for measuring a range of key metabolites with quantification accuracy generally influenced more by data quality than TE choice. The T2 relaxation times of water and metabolites with MRS dominated by a singlet could be estimated using 2 TEs and were found to be significantly different in paediatric brain tumours compared with normal brain, varying between tumour types. The T2 relaxation times of paediatric brain tumours were significantly shorter at 3T compared with 1.5T. Metabolite concentrations for individual patients were most affected by changes in the T2 relaxation time of water which is quick to measure. A clinical JPRESS protocol was developed which aids assignment of overlapping metabolites using changes of MRS with TE. Overall, measurement of MRS with a short TE reduces inaccuracies associated with variability in metabolite T2 and does not tend to lead to worse quantification of overlapping resonances. Further improvements in concentration accuracy can be obtained by measuring case-specific water T2."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/7194/1/Carlin17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7194/2/Decl_IS_Carlin17PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Medical & Dental Sciences","Institute of Cancer and Genomic Sciences"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/7194/"],"dc:subject":["RB Pathology","RC0254 Neoplasms. Tumors. Oncology (including Cancer)","RJ Pediatrics"],"dcterms:accessrights":["public","staffonly"],"dc:title":["An investigation into the importance of T2 relaxation and echo time choice for accurate metabolite biomarker quantification"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:29:14Z"}