{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:7338"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:7338","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Imaging dental ultrasonic cavitation and its effects","abstract":"Current methods of dental biofilm removal are predominantly mechanical and are not effective in removing it from irregular surfaces in the mouth. Cavitation occurs around dental ultrasonic scalers and may be a more efficient and less damaging technique. Previous work has failed to quantify the cavitation bubble dynamics around ultrasonic scalers and its effects. The aim was to develop imaging and analysis protocols to analyse the cavitation and to investigate its ability to disrupt biofilms and deliver sub-micron particles into dentine. High speed imaging was used to characterise cavitation. Its effect on biofilm removal and dentinal tubule occlusion was studied using electron microscopy and x-ray micro computed tomography. We are able to demonstrate that cavitation occurs at the free end of scaler tips and increases with power and vibration amplitude. Biofilm can effectively be removed from dental implant surfaces using this cavitation. It can also be used to transport sub-micron particles further into dentinal tubules. The results show that ultrasonic scalers could be optimised for non-contact use and improved removal of plaque from the teeth. The protocols established in this study can be applied to future studies for quantitative investigation of biofilm growth and removal and analysis of cavitation dynamics.","abstract_html":"Current methods of dental biofilm removal are predominantly mechanical and are not effective in removing it from irregular surfaces in the mouth. Cavitation occurs around dental ultrasonic scalers and may be a more efficient and less damaging technique. Previous work has failed to quantify the cavitation bubble dynamics around ultrasonic scalers and its effects. The aim was to develop imaging and analysis protocols to analyse the cavitation and to investigate its ability to disrupt biofilms and deliver sub-micron particles into dentine. High speed imaging was used to characterise cavitation. Its effect on biofilm removal and dentinal tubule occlusion was studied using electron microscopy and x-ray micro computed tomography. We are able to demonstrate that cavitation occurs at the free end of scaler tips and increases with power and vibration amplitude. Biofilm can effectively be removed from dental implant surfaces using this cavitation. It can also be used to transport sub-micron particles further into dentinal tubules. The results show that ultrasonic scalers could be optimised for non-contact use and improved removal of plaque from the teeth. The protocols established in this study can be applied to future studies for quantitative investigation of biofilm growth and removal and analysis of cavitation dynamics.","abstract_has_math":false,"creators":["Vyas, Nina"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-07","date_published":"2017-07","updated_at":"2026-11-19T09:29:17Z","subjects":["QA75 Electronic computers. Computer science","RC Internal medicine","RK Dentistry"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/7338/5/Vyas17PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A7338","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["epsrc"]},{"key":"dc:creator","label":"Author","values":["Vyas, Nina"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-07"]},{"key":"dc:date.issued","label":"Date","values":["2017-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["School of Dentistry, School of Computer Science, Physical Sciences of Imaging in the Biomedical Sciences"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/7338/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["QA75 Electronic computers. Computer science","RC Internal medicine","RK Dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/7338/5/Vyas17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7338/1/Decl_IS_Vyas17PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Current methods of dental biofilm removal are predominantly mechanical and are not effective in removing it from irregular surfaces in the mouth. Cavitation occurs around dental ultrasonic scalers and may be a more efficient and less damaging technique. Previous work has failed to quantify the cavitation bubble dynamics around ultrasonic scalers and its effects. The aim was to develop imaging and analysis protocols to analyse the cavitation and to investigate its ability to disrupt biofilms and deliver sub-micron particles into dentine. High speed imaging was used to characterise cavitation. Its effect on biofilm removal and dentinal tubule occlusion was studied using electron microscopy and x-ray micro computed tomography. We are able to demonstrate that cavitation occurs at the free end of scaler tips and increases with power and vibration amplitude. Biofilm can effectively be removed from dental implant surfaces using this cavitation. It can also be used to transport sub-micron particles further into dentinal tubules. The results show that ultrasonic scalers could be optimised for non-contact use and improved removal of plaque from the teeth. The protocols established in this study can be applied to future studies for quantitative investigation of biofilm growth and removal and analysis of cavitation dynamics."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Imaging dental ultrasonic cavitation and its effects"]}]}],"canonical_facts":{"dc:contributor.sponsor":["epsrc"],"dc:creator":["Vyas, Nina"],"dc:date":["2017-07"],"dc:date.issued":["2017-07"],"dc:description.abstract":["Current methods of dental biofilm removal are predominantly mechanical and are not effective in removing it from irregular surfaces in the mouth. Cavitation occurs around dental ultrasonic scalers and may be a more efficient and less damaging technique. Previous work has failed to quantify the cavitation bubble dynamics around ultrasonic scalers and its effects. The aim was to develop imaging and analysis protocols to analyse the cavitation and to investigate its ability to disrupt biofilms and deliver sub-micron particles into dentine. High speed imaging was used to characterise cavitation. Its effect on biofilm removal and dentinal tubule occlusion was studied using electron microscopy and x-ray micro computed tomography. We are able to demonstrate that cavitation occurs at the free end of scaler tips and increases with power and vibration amplitude. Biofilm can effectively be removed from dental implant surfaces using this cavitation. It can also be used to transport sub-micron particles further into dentinal tubules. The results show that ultrasonic scalers could be optimised for non-contact use and improved removal of plaque from the teeth. The protocols established in this study can be applied to future studies for quantitative investigation of biofilm growth and removal and analysis of cavitation dynamics."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/7338/5/Vyas17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7338/1/Decl_IS_Vyas17PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["School of Dentistry, School of Computer Science, Physical Sciences of Imaging in the Biomedical Sciences"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/7338/"],"dc:subject":["QA75 Electronic computers. Computer science","RC Internal medicine","RK Dentistry"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Imaging dental ultrasonic cavitation and its effects"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:29:17Z"}