{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:7382"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:7382","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Development and performance characterisation of high concentrating multi-junction PV/Thermal technology","abstract":"Multi-Junction (MJ) solar cells are new generation of Photovoltaic (PV) technology with high efficiency, better response to high solar concentration and lower temperature coefficients. MJ cells are integrated with high concentrating optical systems to maximise their power output. However, high concentration of solar radiation can lead to significant increase in the cells temperature thus cooling is essential which offers potential for heat recovery leading to the development of High Concentrator PV/Thermal (HCPV/T) systems. This thesis presents a detailed investigation of the MJ based HCPV/T optical, electrical and thermal performance. The performance analysis of HCPV/T integrating 0.25x0.25 m\\(^2\\) Fresnel lens under concentration ratios of 425X (X=1000 W/m\\(^2\\)) was carried out to estimate the maximum power output that can be collected. It was found that the yearly total power yield can be up to 191.25 kWh. Therefore, 184 units of HCPV/T, which occupy only 11.5 m\\(^2\\), can generate 35,190 kWh. Also, in comparison to the flat plate Silicon PV module with electrical efficiency of 20% and 1.2x0.8 m\\(^2\\) area, HCPV/T system can save about 76% of the area needed to meet this demand. On the other hand, in terms of pollution these units can displace about 23 tons of CO\\(_2\\) every year.","abstract_html":"Multi-Junction (MJ) solar cells are new generation of Photovoltaic (PV) technology with high efficiency, better response to high solar concentration and lower temperature coefficients. MJ cells are integrated with high concentrating optical systems to maximise their power output. However, high concentration of solar radiation can lead to significant increase in the cells temperature thus cooling is essential which offers potential for heat recovery leading to the development of High Concentrator PV/Thermal (HCPV/T) systems. This thesis presents a detailed investigation of the MJ based HCPV/T optical, electrical and thermal performance. The performance analysis of HCPV/T integrating 0.25x0.25 m<span class=\"etd-inline-math\"><sup>2</sup></span> Fresnel lens under concentration ratios of 425X (X=1000 W/m<span class=\"etd-inline-math\"><sup>2</sup></span>) was carried out to estimate the maximum power output that can be collected. It was found that the yearly total power yield can be up to 191.25 kWh. Therefore, 184 units of HCPV/T, which occupy only 11.5 m<span class=\"etd-inline-math\"><sup>2</sup></span>, can generate 35,190 kWh. Also, in comparison to the flat plate Silicon PV module with electrical efficiency of 20% and 1.2x0.8 m<span class=\"etd-inline-math\"><sup>2</sup></span> area, HCPV/T system can save about 76% of the area needed to meet this demand. On the other hand, in terms of pollution these units can displace about 23 tons of CO<span class=\"etd-inline-math\"><sub>2</sub></span> every year.","abstract_has_math":true,"creators":["Aldossary, Abdulrahman S."],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-07","date_published":"2017-07","updated_at":"2026-11-19T09:29:25Z","subjects":["TJ Mechanical engineering and machinery"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/7382/1/Aldossary17PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A7382","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["other"]},{"key":"dc:creator","label":"Author","values":["Aldossary, Abdulrahman S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-07"]},{"key":"dc:date.issued","label":"Date","values":["2017-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering, Department of Mechanical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/7382/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TJ Mechanical engineering and machinery"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/7382/1/Aldossary17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7382/2/Decl_IS_Aldossary17PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Multi-Junction (MJ) solar cells are new generation of Photovoltaic (PV) technology with high efficiency, better response to high solar concentration and lower temperature coefficients. MJ cells are integrated with high concentrating optical systems to maximise their power output. However, high concentration of solar radiation can lead to significant increase in the cells temperature thus cooling is essential which offers potential for heat recovery leading to the development of High Concentrator PV/Thermal (HCPV/T) systems. This thesis presents a detailed investigation of the MJ based HCPV/T optical, electrical and thermal performance. The performance analysis of HCPV/T integrating 0.25x0.25 m\\(^2\\) Fresnel lens under concentration ratios of 425X (X=1000 W/m\\(^2\\)) was carried out to estimate the maximum power output that can be collected. It was found that the yearly total power yield can be up to 191.25 kWh. Therefore, 184 units of HCPV/T, which occupy only 11.5 m\\(^2\\), can generate 35,190 kWh. Also, in comparison to the flat plate Silicon PV module with electrical efficiency of 20% and 1.2x0.8 m\\(^2\\) area, HCPV/T system can save about 76% of the area needed to meet this demand. On the other hand, in terms of pollution these units can displace about 23 tons of CO\\(_2\\) every year."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Development and performance characterisation of high concentrating multi-junction PV/Thermal technology"]}]}],"canonical_facts":{"dc:contributor.sponsor":["other"],"dc:creator":["Aldossary, Abdulrahman S."],"dc:date":["2017-07"],"dc:date.issued":["2017-07"],"dc:description.abstract":["Multi-Junction (MJ) solar cells are new generation of Photovoltaic (PV) technology with high efficiency, better response to high solar concentration and lower temperature coefficients. MJ cells are integrated with high concentrating optical systems to maximise their power output. However, high concentration of solar radiation can lead to significant increase in the cells temperature thus cooling is essential which offers potential for heat recovery leading to the development of High Concentrator PV/Thermal (HCPV/T) systems. This thesis presents a detailed investigation of the MJ based HCPV/T optical, electrical and thermal performance. The performance analysis of HCPV/T integrating 0.25x0.25 m\\(^2\\) Fresnel lens under concentration ratios of 425X (X=1000 W/m\\(^2\\)) was carried out to estimate the maximum power output that can be collected. It was found that the yearly total power yield can be up to 191.25 kWh. Therefore, 184 units of HCPV/T, which occupy only 11.5 m\\(^2\\), can generate 35,190 kWh. Also, in comparison to the flat plate Silicon PV module with electrical efficiency of 20% and 1.2x0.8 m\\(^2\\) area, HCPV/T system can save about 76% of the area needed to meet this demand. On the other hand, in terms of pollution these units can displace about 23 tons of CO\\(_2\\) every year."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/7382/1/Aldossary17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7382/2/Decl_IS_Aldossary17PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering, Department of Mechanical Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/7382/"],"dc:subject":["TJ Mechanical engineering and machinery"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Development and performance characterisation of high concentrating multi-junction PV/Thermal technology"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:29:25Z"}