{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:7472"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:7472","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Dried blood spot analysis in routine clinical practice","abstract":"Dried blood spots (DBS) are drops of capillary blood collected onto filter paper from a finger prick. They have many advantages compared with traditional phlebotomy and enable patients to take samples at home. A DBS collection device was developed and incorporated into a CE marked DBS collection kit. This was successfully used in an international direct access vitamin D DBS service. A random access DBS CRP method was established for use with the DBS collection device and a new microsampling device called the Mitra. The quality of DBS received and the impact of lancet type was assessed and the effect of blood spot characteristics on CRP and vitamin D concentration was examined. The vitamin D service uptake and the population using it was analysed. The vitamin D concentration and status of users was compared to serum samples received in the laboratory from the local GP population. Significant differences between the populations were seen, with DBS users showing higher levels of vitamin D. In addition, the response to vitamin D testing for both populations was analysed. A higher rate of high to toxic vitamin D levels was seen in the blood spot population and the reasons for this were explored.","abstract_html":"Dried blood spots (DBS) are drops of capillary blood collected onto filter paper from a finger prick. They have many advantages compared with traditional phlebotomy and enable patients to take samples at home. A DBS collection device was developed and incorporated into a CE marked DBS collection kit. This was successfully used in an international direct access vitamin D DBS service. A random access DBS CRP method was established for use with the DBS collection device and a new microsampling device called the Mitra. The quality of DBS received and the impact of lancet type was assessed and the effect of blood spot characteristics on CRP and vitamin D concentration was examined. The vitamin D service uptake and the population using it was analysed. The vitamin D concentration and status of users was compared to serum samples received in the laboratory from the local GP population. Significant differences between the populations were seen, with DBS users showing higher levels of vitamin D. In addition, the response to vitamin D testing for both populations was analysed. A higher rate of high to toxic vitamin D levels was seen in the blood spot population and the reasons for this were explored.","abstract_has_math":false,"creators":["Shea, Robyn Lisa"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-07","date_published":"2017-07","updated_at":"2026-11-19T09:29:25Z","subjects":["RC0254 Neoplasms. Tumors. Oncology (including Cancer)"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/7472/1/Shea17PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A7472","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["other"]},{"key":"dc:creator","label":"Author","values":["Shea, Robyn Lisa"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-07"]},{"key":"dc:date.issued","label":"Date","values":["2017-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Medical & Dental Sciences","Institute of Clinical Sciences"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/7472/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["RC0254 Neoplasms. Tumors. Oncology (including Cancer)"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/7472/1/Shea17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7472/2/Decl_IS_Shea17PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Dried blood spots (DBS) are drops of capillary blood collected onto filter paper from a finger prick. They have many advantages compared with traditional phlebotomy and enable patients to take samples at home. A DBS collection device was developed and incorporated into a CE marked DBS collection kit. This was successfully used in an international direct access vitamin D DBS service. A random access DBS CRP method was established for use with the DBS collection device and a new microsampling device called the Mitra. The quality of DBS received and the impact of lancet type was assessed and the effect of blood spot characteristics on CRP and vitamin D concentration was examined. The vitamin D service uptake and the population using it was analysed. The vitamin D concentration and status of users was compared to serum samples received in the laboratory from the local GP population. Significant differences between the populations were seen, with DBS users showing higher levels of vitamin D. In addition, the response to vitamin D testing for both populations was analysed. A higher rate of high to toxic vitamin D levels was seen in the blood spot population and the reasons for this were explored."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Dried blood spot analysis in routine clinical practice"]}]}],"canonical_facts":{"dc:contributor.sponsor":["other"],"dc:creator":["Shea, Robyn Lisa"],"dc:date":["2017-07"],"dc:date.issued":["2017-07"],"dc:description.abstract":["Dried blood spots (DBS) are drops of capillary blood collected onto filter paper from a finger prick. They have many advantages compared with traditional phlebotomy and enable patients to take samples at home. A DBS collection device was developed and incorporated into a CE marked DBS collection kit. This was successfully used in an international direct access vitamin D DBS service. A random access DBS CRP method was established for use with the DBS collection device and a new microsampling device called the Mitra. The quality of DBS received and the impact of lancet type was assessed and the effect of blood spot characteristics on CRP and vitamin D concentration was examined. The vitamin D service uptake and the population using it was analysed. The vitamin D concentration and status of users was compared to serum samples received in the laboratory from the local GP population. Significant differences between the populations were seen, with DBS users showing higher levels of vitamin D. In addition, the response to vitamin D testing for both populations was analysed. A higher rate of high to toxic vitamin D levels was seen in the blood spot population and the reasons for this were explored."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/7472/1/Shea17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7472/2/Decl_IS_Shea17PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Medical & Dental Sciences","Institute of Clinical Sciences"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/7472/"],"dc:subject":["RC0254 Neoplasms. Tumors. Oncology (including Cancer)"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Dried blood spot analysis in routine clinical practice"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:29:25Z"}