{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:7545"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:7545","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Larval zebrafish electrocardiography electrodynmaic modelling and sensor design","abstract":"This thesis presents the first model of the electrical activity of the larval zebrafish heart as well as the design and fabrication of novel electrode arrays that were created to measure the electrocardiogram. The model consists of realistic 3D geometry of a 3 day’s post fertilisation zebrafish heart and body with a bidomain electrical model that uses the Fitzhugh-Nagumo equations as the ionic model. The model is able to replicate experimentally observed conduction velocities and action potentials by using region specific parameters and simulate electrocardiograms that are comparable to measurements. The electrode arrays are constructed from flexible polyimide films with gold microelectrodes. These devices have the potential to improve the measurement of the electrocardiogram for drug screening applications as an alternative to the use of micropipette electrodes. Gold plating and PEDOT:PSS coating techniques were applied to the devices to successfully reduce electrode impedance with the effectiveness of each technique categorised using impedance spectroscopy. The devices were tested \\(in\\) \\(vivo\\) with larval zebrafish with limited success and so \\(in\\) \\(vitro\\) tests were conducted using an artificial current source.","abstract_html":"This thesis presents the first model of the electrical activity of the larval zebrafish heart as well as the design and fabrication of novel electrode arrays that were created to measure the electrocardiogram. The model consists of realistic 3D geometry of a 3 day’s post fertilisation zebrafish heart and body with a bidomain electrical model that uses the Fitzhugh-Nagumo equations as the ionic model. The model is able to replicate experimentally observed conduction velocities and action potentials by using region specific parameters and simulate electrocardiograms that are comparable to measurements. The electrode arrays are constructed from flexible polyimide films with gold microelectrodes. These devices have the potential to improve the measurement of the electrocardiogram for drug screening applications as an alternative to the use of micropipette electrodes. Gold plating and PEDOT:PSS coating techniques were applied to the devices to successfully reduce electrode impedance with the effectiveness of each technique categorised using impedance spectroscopy. The devices were tested \\(in\\) \\(vivo\\) with larval zebrafish with limited success and so \\(in\\) \\(vitro\\) tests were conducted using an artificial current source.","abstract_has_math":true,"creators":["Crowcombe, James Edward"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-07","date_published":"2017-07","updated_at":"2026-11-19T09:29:31Z","subjects":["TK Electrical engineering. Electronics Nuclear engineering"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/7545/1/Crowcombe17PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A7545","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Crowcombe, James Edward"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-07"]},{"key":"dc:date.issued","label":"Date","values":["2017-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering, Department of Electronic, Electrical and Systems Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/7545/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TK Electrical engineering. Electronics Nuclear engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/7545/1/Crowcombe17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7545/2/Decl_IS_Crowcombe17PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the first model of the electrical activity of the larval zebrafish heart as well as the design and fabrication of novel electrode arrays that were created to measure the electrocardiogram. The model consists of realistic 3D geometry of a 3 day’s post fertilisation zebrafish heart and body with a bidomain electrical model that uses the Fitzhugh-Nagumo equations as the ionic model. The model is able to replicate experimentally observed conduction velocities and action potentials by using region specific parameters and simulate electrocardiograms that are comparable to measurements. The electrode arrays are constructed from flexible polyimide films with gold microelectrodes. These devices have the potential to improve the measurement of the electrocardiogram for drug screening applications as an alternative to the use of micropipette electrodes. Gold plating and PEDOT:PSS coating techniques were applied to the devices to successfully reduce electrode impedance with the effectiveness of each technique categorised using impedance spectroscopy. The devices were tested \\(in\\) \\(vivo\\) with larval zebrafish with limited success and so \\(in\\) \\(vitro\\) tests were conducted using an artificial current source."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Larval zebrafish electrocardiography electrodynmaic modelling and sensor design"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Crowcombe, James Edward"],"dc:date":["2017-07"],"dc:date.issued":["2017-07"],"dc:description.abstract":["This thesis presents the first model of the electrical activity of the larval zebrafish heart as well as the design and fabrication of novel electrode arrays that were created to measure the electrocardiogram. The model consists of realistic 3D geometry of a 3 day’s post fertilisation zebrafish heart and body with a bidomain electrical model that uses the Fitzhugh-Nagumo equations as the ionic model. The model is able to replicate experimentally observed conduction velocities and action potentials by using region specific parameters and simulate electrocardiograms that are comparable to measurements. The electrode arrays are constructed from flexible polyimide films with gold microelectrodes. These devices have the potential to improve the measurement of the electrocardiogram for drug screening applications as an alternative to the use of micropipette electrodes. Gold plating and PEDOT:PSS coating techniques were applied to the devices to successfully reduce electrode impedance with the effectiveness of each technique categorised using impedance spectroscopy. The devices were tested \\(in\\) \\(vivo\\) with larval zebrafish with limited success and so \\(in\\) \\(vitro\\) tests were conducted using an artificial current source."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/7545/1/Crowcombe17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7545/2/Decl_IS_Crowcombe17PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering, Department of Electronic, Electrical and Systems Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/7545/"],"dc:subject":["TK Electrical engineering. Electronics Nuclear engineering"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Larval zebrafish electrocardiography electrodynmaic modelling and sensor design"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:29:31Z"}