{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:7674"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:7674","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Development of reflective low concentrated photovoltaic/ thermal system","abstract":"This work aims to investigate the performance of a new design for CPV/T system using 3D flat sided (3D V-trough) concentrators named squared (SAC), Hexagonal (HAC), Octagonal (OAC) and Circular (CAC) inlet and exit Aperture concentrators, with an effective cooling facility that keeps PV temperature within the Normal operating range. Novel mathematical optical models were generated, to the HAC and OAC geometries and validated using OPTISORKS software, to calculate the geometrical concentration ratio (\\(GCR\\)) and actual concentration ratio (\\(ACR\\) by the inlet aperture area (A\\(_i\\)\\(_n\\)) a function of aperture width (W\\(_i\\)\\(_n\\)) and number of reflections (n), and material reflectivity (\\(p\\)) and at any concentrator side angle (Ψ), consequently the optical performance. Results showed that the optimum concentrator side angels for GCR of 2, 4, 6, 8 and 10 are 35°, 30°, 20°, 20° and 15°, respectively for all investigated geometries. Also COMSOL Multiphysics software was used for thermal modelling. Optical, thermal and electrical investigation results highlight that the designed CPV/T system is beneficial enough and feasible to be used in generating electrical and thermal powers for domestic use, as one useful package of energy with high output compared with the flat PV modules which generate only electrical power.","abstract_html":"This work aims to investigate the performance of a new design for CPV/T system using 3D flat sided (3D V-trough) concentrators named squared (SAC), Hexagonal (HAC), Octagonal (OAC) and Circular (CAC) inlet and exit Aperture concentrators, with an effective cooling facility that keeps PV temperature within the Normal operating range. Novel mathematical optical models were generated, to the HAC and OAC geometries and validated using OPTISORKS software, to calculate the geometrical concentration ratio (\\(GCR\\)) and actual concentration ratio (\\(ACR\\) by the inlet aperture area (A<span class=\"etd-inline-math\"><sub>i</sub></span><span class=\"etd-inline-math\"><sub>n</sub></span>) a function of aperture width (W<span class=\"etd-inline-math\"><sub>i</sub></span><span class=\"etd-inline-math\"><sub>n</sub></span>) and number of reflections (n), and material reflectivity (\\(p\\)) and at any concentrator side angle (Ψ), consequently the optical performance. Results showed that the optimum concentrator side angels for GCR of 2, 4, 6, 8 and 10 are 35°, 30°, 20°, 20° and 15°, respectively for all investigated geometries. Also COMSOL Multiphysics software was used for thermal modelling. Optical, thermal and electrical investigation results highlight that the designed CPV/T system is beneficial enough and feasible to be used in generating electrical and thermal powers for domestic use, as one useful package of energy with high output compared with the flat PV modules which generate only electrical power.","abstract_has_math":true,"creators":["Algareu, Abdulmaged Omer"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017-12","date_published":"2017-12","updated_at":"2026-11-19T09:29:34Z","subjects":["TJ Mechanical engineering and machinery"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/7674/1/Algareu17PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A7674","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Algareu, Abdulmaged Omer"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-12"]},{"key":"dc:date.issued","label":"Date","values":["2017-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering, Department of Mechanical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/7674/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TJ Mechanical engineering and machinery"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/7674/1/Algareu17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7674/2/Decl_IS_Algareu17PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work aims to investigate the performance of a new design for CPV/T system using 3D flat sided (3D V-trough) concentrators named squared (SAC), Hexagonal (HAC), Octagonal (OAC) and Circular (CAC) inlet and exit Aperture concentrators, with an effective cooling facility that keeps PV temperature within the Normal operating range. Novel mathematical optical models were generated, to the HAC and OAC geometries and validated using OPTISORKS software, to calculate the geometrical concentration ratio (\\(GCR\\)) and actual concentration ratio (\\(ACR\\) by the inlet aperture area (A\\(_i\\)\\(_n\\)) a function of aperture width (W\\(_i\\)\\(_n\\)) and number of reflections (n), and material reflectivity (\\(p\\)) and at any concentrator side angle (Ψ), consequently the optical performance. Results showed that the optimum concentrator side angels for GCR of 2, 4, 6, 8 and 10 are 35°, 30°, 20°, 20° and 15°, respectively for all investigated geometries. Also COMSOL Multiphysics software was used for thermal modelling. Optical, thermal and electrical investigation results highlight that the designed CPV/T system is beneficial enough and feasible to be used in generating electrical and thermal powers for domestic use, as one useful package of energy with high output compared with the flat PV modules which generate only electrical power."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Development of reflective low concentrated photovoltaic/ thermal system"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Algareu, Abdulmaged Omer"],"dc:date":["2017-12"],"dc:date.issued":["2017-12"],"dc:description.abstract":["This work aims to investigate the performance of a new design for CPV/T system using 3D flat sided (3D V-trough) concentrators named squared (SAC), Hexagonal (HAC), Octagonal (OAC) and Circular (CAC) inlet and exit Aperture concentrators, with an effective cooling facility that keeps PV temperature within the Normal operating range. Novel mathematical optical models were generated, to the HAC and OAC geometries and validated using OPTISORKS software, to calculate the geometrical concentration ratio (\\(GCR\\)) and actual concentration ratio (\\(ACR\\) by the inlet aperture area (A\\(_i\\)\\(_n\\)) a function of aperture width (W\\(_i\\)\\(_n\\)) and number of reflections (n), and material reflectivity (\\(p\\)) and at any concentrator side angle (Ψ), consequently the optical performance. Results showed that the optimum concentrator side angels for GCR of 2, 4, 6, 8 and 10 are 35°, 30°, 20°, 20° and 15°, respectively for all investigated geometries. Also COMSOL Multiphysics software was used for thermal modelling. Optical, thermal and electrical investigation results highlight that the designed CPV/T system is beneficial enough and feasible to be used in generating electrical and thermal powers for domestic use, as one useful package of energy with high output compared with the flat PV modules which generate only electrical power."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/7674/1/Algareu17PhD.pdf","http://etheses.bham.ac.uk//id/eprint/7674/2/Decl_IS_Algareu17PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering, Department of Mechanical Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/7674/"],"dc:subject":["TJ Mechanical engineering and machinery"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Development of reflective low concentrated photovoltaic/ thermal system"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:29:34Z"}