{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:8094"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:8094","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"The investigation of the effect of plan irregularities on the progressive collapse response of low to medium rise steel structures","abstract":"This research examines the effect of plan irregularities on the progressive collapse of steel structures. Firstly, 2, 3 and 5-storey steel structures, regular and irregular, located in regions with different seismic activity designed in accordance with AISC (20 I 0) and ASCE7 (20 I 0). Secondly, the effect of the four plan irregularities on the progressive collapse of braced and unbraced steel structures located in regions with different seismic activity assessed. The collapse patterns of the I4 buildings is analysed and compared under seven loading scenarios using nonlinear dynamic and static analyses. In the nonlinear dynamic analyses, node displacements above the removed columns and the additional force on the columns adjacent to them are discussed. Furthermore, the capacity of the columns is compared to determine their susceptibility to collapse. ln the nonlinear static analyses, the pushdown curve and yield load factor of the structures are obtained after column removal. The results indicate that an irregular structure designed in site class C seismic zone collapses in most of the column removal scenarios. Moreover, when comparing regular and irregular structures designed in site class E seismic zone, the demand force to capacity ratio (D/C) of the columns in the irregular structures is on average between I.5 and 2 times that of the regular ones has been discussed by Homaioon Ebrahimi et.al (20 I7). The lack of 2-storey building bearing capacity to withstand the removal of the column is lower than that of the 5-storey structure, which is due to the level of redundancy that characterises in the 5-storey structure.","abstract_html":"This research examines the effect of plan irregularities on the progressive collapse of steel structures. Firstly, 2, 3 and 5-storey steel structures, regular and irregular, located in regions with different seismic activity designed in accordance with AISC (20 I 0) and ASCE7 (20 I 0). Secondly, the effect of the four plan irregularities on the progressive collapse of braced and unbraced steel structures located in regions with different seismic activity assessed. The collapse patterns of the I4 buildings is analysed and compared under seven loading scenarios using nonlinear dynamic and static analyses. In the nonlinear dynamic analyses, node displacements above the removed columns and the additional force on the columns adjacent to them are discussed. Furthermore, the capacity of the columns is compared to determine their susceptibility to collapse. ln the nonlinear static analyses, the pushdown curve and yield load factor of the structures are obtained after column removal. The results indicate that an irregular structure designed in site class C seismic zone collapses in most of the column removal scenarios. Moreover, when comparing regular and irregular structures designed in site class E seismic zone, the demand force to capacity ratio (D/C) of the columns in the irregular structures is on average between I.5 and 2 times that of the regular ones has been discussed by Homaioon Ebrahimi et.al (20 I7). The lack of 2-storey building bearing capacity to withstand the removal of the column is lower than that of the 5-storey structure, which is due to the level of redundancy that characterises in the 5-storey structure.","abstract_has_math":false,"creators":["Homaioon Ebrahimi, Amir"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-12","date_published":"2018-12","updated_at":"2026-11-19T09:29:44Z","subjects":["TA Engineering (General). Civil engineering (General)","TG Bridge engineering","TH Building construction"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/8094/1/Homaioon18PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A8094","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Homaioon Ebrahimi, Amir"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-12"]},{"key":"dc:date.issued","label":"Date","values":["2018-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Engineering, Department of Civil Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/8094/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TA Engineering (General). Civil engineering (General)","TG Bridge engineering","TH Building construction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/8094/1/Homaioon18PhD.pdf","http://etheses.bham.ac.uk//id/eprint/8094/2/Decl_IS_Homaioon18PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research examines the effect of plan irregularities on the progressive collapse of steel structures. Firstly, 2, 3 and 5-storey steel structures, regular and irregular, located in regions with different seismic activity designed in accordance with AISC (20 I 0) and ASCE7 (20 I 0). Secondly, the effect of the four plan irregularities on the progressive collapse of braced and unbraced steel structures located in regions with different seismic activity assessed. The collapse patterns of the I4 buildings is analysed and compared under seven loading scenarios using nonlinear dynamic and static analyses. In the nonlinear dynamic analyses, node displacements above the removed columns and the additional force on the columns adjacent to them are discussed. Furthermore, the capacity of the columns is compared to determine their susceptibility to collapse. ln the nonlinear static analyses, the pushdown curve and yield load factor of the structures are obtained after column removal. The results indicate that an irregular structure designed in site class C seismic zone collapses in most of the column removal scenarios. Moreover, when comparing regular and irregular structures designed in site class E seismic zone, the demand force to capacity ratio (D/C) of the columns in the irregular structures is on average between I.5 and 2 times that of the regular ones has been discussed by Homaioon Ebrahimi et.al (20 I7). The lack of 2-storey building bearing capacity to withstand the removal of the column is lower than that of the 5-storey structure, which is due to the level of redundancy that characterises in the 5-storey structure."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["The investigation of the effect of plan irregularities on the progressive collapse response of low to medium rise steel structures"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Homaioon Ebrahimi, Amir"],"dc:date":["2018-12"],"dc:date.issued":["2018-12"],"dc:description.abstract":["This research examines the effect of plan irregularities on the progressive collapse of steel structures. Firstly, 2, 3 and 5-storey steel structures, regular and irregular, located in regions with different seismic activity designed in accordance with AISC (20 I 0) and ASCE7 (20 I 0). Secondly, the effect of the four plan irregularities on the progressive collapse of braced and unbraced steel structures located in regions with different seismic activity assessed. The collapse patterns of the I4 buildings is analysed and compared under seven loading scenarios using nonlinear dynamic and static analyses. In the nonlinear dynamic analyses, node displacements above the removed columns and the additional force on the columns adjacent to them are discussed. Furthermore, the capacity of the columns is compared to determine their susceptibility to collapse. ln the nonlinear static analyses, the pushdown curve and yield load factor of the structures are obtained after column removal. The results indicate that an irregular structure designed in site class C seismic zone collapses in most of the column removal scenarios. Moreover, when comparing regular and irregular structures designed in site class E seismic zone, the demand force to capacity ratio (D/C) of the columns in the irregular structures is on average between I.5 and 2 times that of the regular ones has been discussed by Homaioon Ebrahimi et.al (20 I7). The lack of 2-storey building bearing capacity to withstand the removal of the column is lower than that of the 5-storey structure, which is due to the level of redundancy that characterises in the 5-storey structure."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/8094/1/Homaioon18PhD.pdf","http://etheses.bham.ac.uk//id/eprint/8094/2/Decl_IS_Homaioon18PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Engineering, Department of Civil Engineering"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/8094/"],"dc:subject":["TA Engineering (General). Civil engineering (General)","TG Bridge engineering","TH Building construction"],"dcterms:accessrights":["public","staffonly"],"dc:title":["The investigation of the effect of plan irregularities on the progressive collapse response of low to medium rise steel structures"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:29:44Z"}