{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:8698"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:8698","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Fibre-optic sensor development for process monitoring of epoxy resins","abstract":"An investigation was undertaken to examine the performance of a Fresnel reflection sensor (FRS) incorporated into a differential scanning calorimeter (DSC) to track the cross-linking of epoxy resins. The initial design used a micrometer translation stage to lower the FRS through an orifice in the DSC platinum lid and onto the pan containing the sample. During exothermic cross-linking experiments, the resin refractive index and the heat evolved were measured simultaneously, allowing for direct comparison between the data. Combining the two measurement techniques produced a powerful hyphenated analytical procedure that demonstrated the feasibility of using the FRS for in-situ cure monitoring of epoxy resin systems. During the cross-linking of specified resins, the sensor revealed optical phenomena throughout the latter stages and was shown to be sensitive to the glass transition temperature, nano-particulate movement, nano-particulate concentration and phase separation. Therefore, the introduction of the FRS to the DSC provided valuable cross-linking information. A second modification to the DSC permitted the accommodation of an optical fibre probe, which facilitated simultaneous DSC/FRS/Fourier transform infrared spectroscopy (FTIRS) analysis. Good correlation between the cross-linking kinetics of an epoxy resin system was demonstrated using the hyphenated techniques and hence alleviated the issues of cross-correlation between individual experiments.","abstract_html":"An investigation was undertaken to examine the performance of a Fresnel reflection sensor (FRS) incorporated into a differential scanning calorimeter (DSC) to track the cross-linking of epoxy resins. The initial design used a micrometer translation stage to lower the FRS through an orifice in the DSC platinum lid and onto the pan containing the sample. During exothermic cross-linking experiments, the resin refractive index and the heat evolved were measured simultaneously, allowing for direct comparison between the data. Combining the two measurement techniques produced a powerful hyphenated analytical procedure that demonstrated the feasibility of using the FRS for in-situ cure monitoring of epoxy resin systems. During the cross-linking of specified resins, the sensor revealed optical phenomena throughout the latter stages and was shown to be sensitive to the glass transition temperature, nano-particulate movement, nano-particulate concentration and phase separation. Therefore, the introduction of the FRS to the DSC provided valuable cross-linking information. A second modification to the DSC permitted the accommodation of an optical fibre probe, which facilitated simultaneous DSC/FRS/Fourier transform infrared spectroscopy (FTIRS) analysis. Good correlation between the cross-linking kinetics of an epoxy resin system was demonstrated using the hyphenated techniques and hence alleviated the issues of cross-correlation between individual experiments.","abstract_has_math":false,"creators":["King, David Gareth"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-12","date_published":"2018-12","updated_at":"2026-11-19T09:30:21Z","subjects":["TN Mining engineering. Metallurgy"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/8698/1/King18PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A8698","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["King, David Gareth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-12"]},{"key":"dc:date.issued","label":"Date","values":["2018-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/8698/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["TN Mining engineering. Metallurgy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/8698/1/King18PhD.pdf","http://etheses.bham.ac.uk//id/eprint/8698/2/Decl_IS_King18PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An investigation was undertaken to examine the performance of a Fresnel reflection sensor (FRS) incorporated into a differential scanning calorimeter (DSC) to track the cross-linking of epoxy resins. The initial design used a micrometer translation stage to lower the FRS through an orifice in the DSC platinum lid and onto the pan containing the sample. During exothermic cross-linking experiments, the resin refractive index and the heat evolved were measured simultaneously, allowing for direct comparison between the data. Combining the two measurement techniques produced a powerful hyphenated analytical procedure that demonstrated the feasibility of using the FRS for in-situ cure monitoring of epoxy resin systems. During the cross-linking of specified resins, the sensor revealed optical phenomena throughout the latter stages and was shown to be sensitive to the glass transition temperature, nano-particulate movement, nano-particulate concentration and phase separation. Therefore, the introduction of the FRS to the DSC provided valuable cross-linking information. A second modification to the DSC permitted the accommodation of an optical fibre probe, which facilitated simultaneous DSC/FRS/Fourier transform infrared spectroscopy (FTIRS) analysis. Good correlation between the cross-linking kinetics of an epoxy resin system was demonstrated using the hyphenated techniques and hence alleviated the issues of cross-correlation between individual experiments."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public","staffonly"]},{"key":"dc:title","label":"Title","values":["Fibre-optic sensor development for process monitoring of epoxy resins"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["King, David Gareth"],"dc:date":["2018-12"],"dc:date.issued":["2018-12"],"dc:description.abstract":["An investigation was undertaken to examine the performance of a Fresnel reflection sensor (FRS) incorporated into a differential scanning calorimeter (DSC) to track the cross-linking of epoxy resins. The initial design used a micrometer translation stage to lower the FRS through an orifice in the DSC platinum lid and onto the pan containing the sample. During exothermic cross-linking experiments, the resin refractive index and the heat evolved were measured simultaneously, allowing for direct comparison between the data. Combining the two measurement techniques produced a powerful hyphenated analytical procedure that demonstrated the feasibility of using the FRS for in-situ cure monitoring of epoxy resin systems. During the cross-linking of specified resins, the sensor revealed optical phenomena throughout the latter stages and was shown to be sensitive to the glass transition temperature, nano-particulate movement, nano-particulate concentration and phase separation. Therefore, the introduction of the FRS to the DSC provided valuable cross-linking information. A second modification to the DSC permitted the accommodation of an optical fibre probe, which facilitated simultaneous DSC/FRS/Fourier transform infrared spectroscopy (FTIRS) analysis. Good correlation between the cross-linking kinetics of an epoxy resin system was demonstrated using the hyphenated techniques and hence alleviated the issues of cross-correlation between individual experiments."],"dc:format":["application/pdf"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/8698/1/King18PhD.pdf","http://etheses.bham.ac.uk//id/eprint/8698/2/Decl_IS_King18PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Metallurgy and Materials"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/8698/"],"dc:subject":["TN Mining engineering. Metallurgy"],"dcterms:accessrights":["public","staffonly"],"dc:title":["Fibre-optic sensor development for process monitoring of epoxy resins"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:30:21Z"}