{"id":{"repo_id":"birmingham","oai_identifier":"oai:etheses.bham.ac.uk:9509"},"canonical_url":"https://search.ndltd.org/etd/birmingham/oai:etheses.bham.ac.uk:9509","repository":{"repo_id":"birmingham","name":"University of Birmingham","base_url":"https://etheses.bham.ac.uk/cgi/oai2"},"display":{"title":"Cold atom gravity gradiometer for field applications","abstract":"This thesis presents the first efficient implementation of a 87Rb prism MOT gravity gradiometer. The resulting portable system (weight <50 kg and volume <0.1 m3) is capable of producing atom numbers up to 5 × 107 with typical cloud temperatures of 7.8 µK. Combining with a robust control system and a 5 m delivery umbilical the effectiveness has been demonstrated in a non-laboratory environment. A measurement campaign to detect a buried maintenance tunnel, with an expected signal size of 230 E, was performed during March 2018. An ambient temperature range of -0.5 to 10.2 ◦C and wind speeds in excess of 10 m/s provided adverse operating conditions that imposed no loss of functionality on the sensor. Resulting data shows a trend indicative of the tunnel with long term drift limiting fit error to 140 E. A second campaign was performed to detect a signal of 280 E generated by a lead mass of 450 kg in a laboratory environment, with ambient temperature fluctuations of 0.5 ◦C recorded. Sensor drift of ∼220 E/hour was seen making it impossible to discern the expected signal. Correlation between the Raman sideband-to-carrier amplitude ratio and measured gradient signal was identified and linked to ambient temperature fluctuations.","abstract_html":"This thesis presents the first efficient implementation of a 87Rb prism MOT gravity gradiometer. The resulting portable system (weight &lt;50 kg and volume &lt;0.1 m3) is capable of producing atom numbers up to 5 × 107 with typical cloud temperatures of 7.8 µK. Combining with a robust control system and a 5 m delivery umbilical the effectiveness has been demonstrated in a non-laboratory environment. A measurement campaign to detect a buried maintenance tunnel, with an expected signal size of 230 E, was performed during March 2018. An ambient temperature range of -0.5 to 10.2 ◦C and wind speeds in excess of 10 m/s provided adverse operating conditions that imposed no loss of functionality on the sensor. Resulting data shows a trend indicative of the tunnel with long term drift limiting fit error to 140 E. A second campaign was performed to detect a signal of 280 E generated by a lead mass of 450 kg in a laboratory environment, with ambient temperature fluctuations of 0.5 ◦C recorded. Sensor drift of ∼220 E/hour was seen making it impossible to discern the expected signal. Correlation between the Raman sideband-to-carrier amplitude ratio and measured gradient signal was identified and linked to ambient temperature fluctuations.","abstract_has_math":false,"creators":["Lamb, Andrew Anuerin"],"institution":"University of Birmingham","degree_name":"d_ph","degree_level":"d_ph","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-07","date_published":"2019-07","updated_at":"2026-11-19T09:30:48Z","subjects":["QB Astronomy","QC Physics"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null,"record_url":null,"record_label":null,"record_kind":null,"record_source":null,"download_url":"http://etheses.bham.ac.uk//id/eprint/9509/1/Lamb2019PhD.pdf","download_label":"Download PDF","download_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://etheses.bham.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aetheses.bham.ac.uk%3A9509","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.sponsor","label":"Sponsor","values":["na"]},{"key":"dc:creator","label":"Author","values":["Lamb, Andrew Anuerin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-07-11"]},{"key":"dc:date.issued","label":"Date","values":["2019-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["College of Engineering & Physical Sciences","School of Physics and Astronomy"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Birmingham"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["http://etheses.bham.ac.uk//id/eprint/9509/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["d_ph"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["d_ph"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["QB Astronomy","QC Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.dcterms_iso639_2","label":"Language (ISO 639-2)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://etheses.bham.ac.uk//id/eprint/9509/1/Lamb2019PhD.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the first efficient implementation of a 87Rb prism MOT gravity gradiometer. The resulting portable system (weight <50 kg and volume <0.1 m3) is capable of producing atom numbers up to 5 × 107 with typical cloud temperatures of 7.8 µK. Combining with a robust control system and a 5 m delivery umbilical the effectiveness has been demonstrated in a non-laboratory environment. A measurement campaign to detect a buried maintenance tunnel, with an expected signal size of 230 E, was performed during March 2018. An ambient temperature range of -0.5 to 10.2 ◦C and wind speeds in excess of 10 m/s provided adverse operating conditions that imposed no loss of functionality on the sensor. Resulting data shows a trend indicative of the tunnel with long term drift limiting fit error to 140 E. A second campaign was performed to detect a signal of 280 E generated by a lead mass of 450 kg in a laboratory environment, with ambient temperature fluctuations of 0.5 ◦C recorded. Sensor drift of ∼220 E/hour was seen making it impossible to discern the expected signal. Correlation between the Raman sideband-to-carrier amplitude ratio and measured gradient signal was identified and linked to ambient temperature fluctuations."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Cold atom gravity gradiometer for field applications"]}]}],"canonical_facts":{"dc:contributor.sponsor":["na"],"dc:creator":["Lamb, Andrew Anuerin"],"dc:date":["2019-07-11"],"dc:date.issued":["2019-07"],"dc:description.abstract":["This thesis presents the first efficient implementation of a 87Rb prism MOT gravity gradiometer. The resulting portable system (weight <50 kg and volume <0.1 m3) is capable of producing atom numbers up to 5 × 107 with typical cloud temperatures of 7.8 µK. Combining with a robust control system and a 5 m delivery umbilical the effectiveness has been demonstrated in a non-laboratory environment. A measurement campaign to detect a buried maintenance tunnel, with an expected signal size of 230 E, was performed during March 2018. An ambient temperature range of -0.5 to 10.2 ◦C and wind speeds in excess of 10 m/s provided adverse operating conditions that imposed no loss of functionality on the sensor. Resulting data shows a trend indicative of the tunnel with long term drift limiting fit error to 140 E. A second campaign was performed to detect a signal of 280 E generated by a lead mass of 450 kg in a laboratory environment, with ambient temperature fluctuations of 0.5 ◦C recorded. Sensor drift of ∼220 E/hour was seen making it impossible to discern the expected signal. Correlation between the Raman sideband-to-carrier amplitude ratio and measured gradient signal was identified and linked to ambient temperature fluctuations."],"dc:format":["text"],"dc:identifier.uri":["http://etheses.bham.ac.uk//id/eprint/9509/1/Lamb2019PhD.pdf"],"dc:language.dcterms_iso639_2":["eng"],"dc:publisher.department":["College of Engineering & Physical Sciences","School of Physics and Astronomy"],"dc:publisher.institution":["University of Birmingham"],"dc:relation.isreferencedby":["http://etheses.bham.ac.uk//id/eprint/9509/"],"dc:subject":["QB Astronomy","QC Physics"],"dcterms:accessrights":["public"],"dc:title":["Cold atom gravity gradiometer for field applications"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["d_ph"],"dc:type.qualificationname":["d_ph"]},"updated_at":"2026-11-19T09:30:48Z"}