{"id":{"repo_id":"botswana","oai_identifier":"oai:ubrisa.ub.bw:10311/2386"},"canonical_url":"https://search.ndltd.org/etd/botswana/oai:ubrisa.ub.bw:10311/2386","repository":{"repo_id":"botswana","name":"University Botswana","base_url":"https://ubrisa.ub.bw/oai/request"},"display":{"title":"Development of an indoor air temperature predictive model for a naturally ventilated adobe mud hut; Botswana winter climatic conditions","abstract":"A transient heat transfer model to predict the indoor air temperature within a Botswana traditional hut (made of adobe/mud bricks) is developed from Fourier’s law of heat transfer, taking into consideration conduction, convection and irradiance. The predictive model was developed and analysed using MATLAB and correlated against in-situ experiments taken on July 5th 2018. They are then validated with a new data set as collected on July 7th2018. At 95% variance level the model demonstrates an excellent strength of association against actual indoor temperature at a correlation coefficient of 0.9, with an impressively low RMSE of 0.45◦C and an R-squared value of 65%, which is a fairly acceptable goodness of fit. Given the global need for energy saving, environment symbiosis and energy optimization, it is important to develop and improve natural ventilation predictive models to guide decision makers. With other environmental design methodologies, the model developed in this study should influence national housing policy towards sustainable indigenous construction; inform the development of natural building standards and indoor air quality strategies of the hot and dry climatic countries globally.","abstract_html":"A transient heat transfer model to predict the indoor air temperature within a Botswana traditional hut (made of adobe/mud bricks) is developed from Fourier’s law of heat transfer, taking into consideration conduction, convection and irradiance. The predictive model was developed and analysed using MATLAB and correlated against in-situ experiments taken on July 5th 2018. They are then validated with a new data set as collected on July 7th2018. At 95% variance level the model demonstrates an excellent strength of association against actual indoor temperature at a correlation coefficient of 0.9, with an impressively low RMSE of 0.45◦C and an R-squared value of 65%, which is a fairly acceptable goodness of fit. Given the global need for energy saving, environment symbiosis and energy optimization, it is important to develop and improve natural ventilation predictive models to guide decision makers. With other environmental design methodologies, the model developed in this study should influence national housing policy towards sustainable indigenous construction; inform the development of natural building standards and indoor air quality strategies of the hot and dry climatic countries globally.","abstract_has_math":false,"creators":["Letlhare-Wastikc, Kabo"],"institution":"University of Botswana, www.ub.bw","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-08","date_published":"2019-08","updated_at":"2026-11-19T17:38:58Z","subjects":["Indoor air temperature","traditional hut","heat transfer","Fourier’s law of heat transfer"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10311/2386","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10311/2386","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abotswana%3Aoai%3Aubrisa.ub.bw%3A10311%2F2386","prefix":"oai_dc"},"source_record":{"url":"https://ubrisa.ub.bw/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aubrisa.ub.bw%3A10311%2F2386","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Letlhare-Wastikc, Kabo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2022-04-19T09:02:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2022-04-19T09:02:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2019-08"]},{"key":"dc:publisher","label":"Institution","values":["University of Botswana, www.ub.bw"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis/Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Indoor air temperature","traditional hut","heat transfer","Fourier’s law of heat transfer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10311/2386"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A dissertation submitted to the Dept. of Mechanical Engineering, Faculty of Engineering and Technology, University of Botswana in partial fulfillment of the requirement of the degree of Masters in Mechanical Engineering. Citation: Letlhare-Wastikc, K. (2019) Development of an indoor air temperature predictive model for a naturally ventilated adobe mud hut; Botswana winter climatic conditions."]},{"key":"dc:description.abstract","label":"Abstract","values":["A transient heat transfer model to predict the indoor air temperature within a Botswana traditional hut (made of adobe/mud bricks) is developed from Fourier’s law of heat transfer, taking into consideration conduction, convection and irradiance. The predictive model was developed and analysed using MATLAB and correlated against in-situ experiments taken on July 5th 2018. They are then validated with a new data set as collected on July 7th2018. At 95% variance level the model demonstrates an excellent strength of association against actual indoor temperature at a correlation coefficient of 0.9, with an impressively low RMSE of 0.45◦C and an R-squared value of 65%, which is a fairly acceptable goodness of fit. Given the global need for energy saving, environment symbiosis and energy optimization, it is important to develop and improve natural ventilation predictive models to guide decision makers. With other environmental design methodologies, the model developed in this study should influence national housing policy towards sustainable indigenous construction; inform the development of natural building standards and indoor air quality strategies of the hot and dry climatic countries globally."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["Submitted by Isaac Thothe (thotheim@ub.ac.bw) on 2022-04-13T10:11:38Z No. of bitstreams: 1 Letlhare-Wastikc_Unpublished (MSc)_2019.pdf: 3684263 bytes, checksum: 609369b9bcbdc4e57ed6388e09302990 (MD5)","Approved for entry into archive by Oarabile Rakgamanyane (rakgamanyane@ub.ac.bw) on 2022-04-19T09:02:52Z (GMT) No. of bitstreams: 1 Letlhare-Wastikc_Unpublished (MSc)_2019.pdf: 3684263 bytes, checksum: 609369b9bcbdc4e57ed6388e09302990 (MD5)","Made available in DSpace on 2022-04-19T09:02:52Z (GMT). No. of bitstreams: 1 Letlhare-Wastikc_Unpublished (MSc)_2019.pdf: 3684263 bytes, checksum: 609369b9bcbdc4e57ed6388e09302990 (MD5) Previous issue date: 2019-08"]},{"key":"dc:title","label":"Title","values":["Development of an indoor air temperature predictive model for a naturally ventilated adobe mud hut; Botswana winter climatic conditions"]}]}],"canonical_facts":{"dc:creator":["Letlhare-Wastikc, Kabo"],"dc:date.accessioned":["2022-04-19T09:02:52Z"],"dc:date.available":["2022-04-19T09:02:52Z"],"dc:date.issued":["2019-08"],"dc:description":["A dissertation submitted to the Dept. of Mechanical Engineering, Faculty of Engineering and Technology, University of Botswana in partial fulfillment of the requirement of the degree of Masters in Mechanical Engineering. Citation: Letlhare-Wastikc, K. (2019) Development of an indoor air temperature predictive model for a naturally ventilated adobe mud hut; Botswana winter climatic conditions."],"dc:description.abstract":["A transient heat transfer model to predict the indoor air temperature within a Botswana traditional hut (made of adobe/mud bricks) is developed from Fourier’s law of heat transfer, taking into consideration conduction, convection and irradiance. The predictive model was developed and analysed using MATLAB and correlated against in-situ experiments taken on July 5th 2018. They are then validated with a new data set as collected on July 7th2018. At 95% variance level the model demonstrates an excellent strength of association against actual indoor temperature at a correlation coefficient of 0.9, with an impressively low RMSE of 0.45◦C and an R-squared value of 65%, which is a fairly acceptable goodness of fit. Given the global need for energy saving, environment symbiosis and energy optimization, it is important to develop and improve natural ventilation predictive models to guide decision makers. With other environmental design methodologies, the model developed in this study should influence national housing policy towards sustainable indigenous construction; inform the development of natural building standards and indoor air quality strategies of the hot and dry climatic countries globally."],"dc:description.provenance":["Submitted by Isaac Thothe (thotheim@ub.ac.bw) on 2022-04-13T10:11:38Z No. of bitstreams: 1 Letlhare-Wastikc_Unpublished (MSc)_2019.pdf: 3684263 bytes, checksum: 609369b9bcbdc4e57ed6388e09302990 (MD5)","Approved for entry into archive by Oarabile Rakgamanyane (rakgamanyane@ub.ac.bw) on 2022-04-19T09:02:52Z (GMT) No. of bitstreams: 1 Letlhare-Wastikc_Unpublished (MSc)_2019.pdf: 3684263 bytes, checksum: 609369b9bcbdc4e57ed6388e09302990 (MD5)","Made available in DSpace on 2022-04-19T09:02:52Z (GMT). No. of bitstreams: 1 Letlhare-Wastikc_Unpublished (MSc)_2019.pdf: 3684263 bytes, checksum: 609369b9bcbdc4e57ed6388e09302990 (MD5) Previous issue date: 2019-08"],"dc:identifier.uri":["http://hdl.handle.net/10311/2386"],"dc:language.iso":["en"],"dc:publisher":["University of Botswana, www.ub.bw"],"dc:subject":["Indoor air temperature","traditional hut","heat transfer","Fourier’s law of heat transfer"],"dc:title":["Development of an indoor air temperature predictive model for a naturally ventilated adobe mud hut; Botswana winter climatic conditions"],"dc:type":["Masters Thesis/Dissertation"]},"updated_at":"2026-11-19T17:38:58Z"}