{"id":{"repo_id":"brazil-uff","oai_identifier":"oai:app.uff.br:1/19294"},"canonical_url":"https://search.ndltd.org/etd/brazil-uff/oai:app.uff.br:1/19294","repository":{"repo_id":"brazil-uff","name":"Brazil UFF","base_url":"https://app.uff.br/oai/request"},"display":{"title":"SISTEMA DE COMBATE A INCÊNDIO UTILIZANDO A TECNOLOGIA DE ÁGUA NEBULIZADA (WATER MIST) EM INSTALAÇÕES OFFSHORE","abstract":"Offshore rigs and petroleum production units usually require some fire protection and they have many compartments to protect. Water mist system is one among the fire fighting systems available. The water mist system is suitable for liquids fire (class B), solid fuels fire (class A) and electric equipments (class C). It uses small water droplets for fire extinction, suppression and fire control. Test protocols were developed by International Maritime Organization (I.M.O.) aside with National Fire Protection Association (NFPA). These institutions emitted in 2001 the standard NFPA 750 Standard on Water Mist Fire Protection. These protocols and the standard are references for design developments and tests and are used by companies worldwide. This paper proposes to spread the water mist technology, exploiting its operation mechanisms, its application on offshore rigs and petroleum production units, stressing the test of this technology on electric panels.","abstract_html":"Offshore rigs and petroleum production units usually require some fire protection and they have many compartments to protect. Water mist system is one among the fire fighting systems available. The water mist system is suitable for liquids fire (class B), solid fuels fire (class A) and electric equipments (class C). It uses small water droplets for fire extinction, suppression and fire control. Test protocols were developed by International Maritime Organization (I.M.O.) aside with National Fire Protection Association (NFPA). These institutions emitted in 2001 the standard NFPA 750 Standard on Water Mist Fire Protection. These protocols and the standard are references for design developments and tests and are used by companies worldwide. This paper proposes to spread the water mist technology, exploiting its operation mechanisms, its application on offshore rigs and petroleum production units, stressing the test of this technology on electric panels.","abstract_has_math":false,"creators":["Costa Neto, Felicio Pedro da"],"institution":"Programa de Pós-graduação em Sistemas de Gestão","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Mainier, Fernando Benedicto"],"committee_chairs":[],"committee_members":["Lima, Gilson Brito Alves","Gomes, Paulo Alcantara"],"year":2008,"date_issued":"2008-11-24","date_published":"2008-11-24","updated_at":"2026-11-26T20:40:31Z","subjects":["Water Mist. Incêndio","Bicos Aspersores","Agente Extintor","Water Mist","Fire","Nozzle","Extinguishing Agent"],"languages":["por"],"rights":["Acesso Aberto"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.lattes","label":"Lattes CV","values":["http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4707002D6","http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4791172A4&dataRevisao=null"],"render_values":[{"text":"http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4707002D6","href":"http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4707002D6","code":true},{"text":"http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4791172A4&dataRevisao=null","href":"http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4791172A4&dataRevisao=null","code":true}]}]},"links":{"outbound_url":"https://app.uff.br/riuff/handle/1/19294","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://app.uff.br/riuff/handle/1/19294","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrazil-uff%3Aoai%3Aapp.uff.br%3A1%2F19294","prefix":"oai_dc"},"source_record":{"url":"https://app.uff.br/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aapp.uff.br%3A1%2F19294","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mainier, Fernando Benedicto"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lima, Gilson Brito Alves","Gomes, Paulo Alcantara"]},{"key":"dc:creator","label":"Author","values":["Costa Neto, Felicio Pedro da"]},{"key":"person:identifier.lattes","label":"Lattes CV","values":["http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4707002D6","http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4791172A4&dataRevisao=null"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-03-10T20:47:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-07-07","2021-03-10T20:47:02Z"]},{"key":"dc:date.issued","label":"Date","values":["2008-11-24"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Segurança do Trabalho, Meio-ambiente, Gestão pela Qualidade Total"]},{"key":"dc:publisher.program","label":"Dc Publisher Program","values":["Programa de Pós-graduação em Sistemas de Gestão"]},{"key":"dc:type","label":"Dc Type","values":["Dissertação"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Water Mist. Incêndio","Bicos Aspersores","Agente Extintor","Water Mist","Fire","Nozzle","Extinguishing Agent"]},{"key":"dc:subject.cnpq","label":"Dc Subject Cnpq","values":["CNPQ::ENGENHARIAS::ENGENHARIA DE PRODUCAO"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["por"]},{"key":"dc:rights","label":"Dc Rights","values":["Acesso Aberto"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["CC-BY-SA"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://app.uff.br/riuff/handle/1/19294"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Offshore rigs and petroleum production units usually require some fire protection and they have many compartments to protect. Water mist system is one among the fire fighting systems available. The water mist system is suitable for liquids fire (class B), solid fuels fire (class A) and electric equipments (class C). It uses small water droplets for fire extinction, suppression and fire control. Test protocols were developed by International Maritime Organization (I.M.O.) aside with National Fire Protection Association (NFPA). These institutions emitted in 2001 the standard NFPA 750 Standard on Water Mist Fire Protection. These protocols and the standard are references for design developments and tests and are used by companies worldwide. This paper proposes to spread the water mist technology, exploiting its operation mechanisms, its application on offshore rigs and petroleum production units, stressing the test of this technology on electric panels.","Em geral toda instalação offshore requer de alguma forma de proteção contra incêndio e há muitos compartimentos a serem protegidos e um dos meios de proteção que pode ser utilizado é o Sistema de Combate a Incêndio com Água Nebulizada (Water Mist). O Sistema de Proteção com Água Nebulizada (Water Mist) é um sistema que tem a capacidade de combater incêndios em líquidos combustíveis e inflamáveis (Classe B), incêndios em combustíveis sólidos (Classe A) e em equipamentos elétricos (Classe C); utilizando a água em forma de pequenas gotas para realizar a extinção, supressão e o controle do incêndio. Protocolos de testes foram desenvolvidos pelo International Maritime Organization (I.M.O.) juntamente com a National Fire Protection Association, que emitiu em 2001 o padrão, NFPA 750 - Standard on Water Mist Fire Protection. Estes protocolos e o padrão são as referências para o desenvolvimento de projetos, testes e são utilizados pelas empresas em todo o mundo. A presente dissertação propõe divulgar a tecnologia de água nebulizada (Water Mist), explorando os seus mecanismos de atuação, sua aplicabilidade em unidade de perfuração e produção offshore de petróleo, tendo como principal motivo o teste da tecnologia em painéis elétricos."]},{"key":"dc:description.sponsorship","label":"Dc Description Sponsorship","values":["Universidade Federal Fluminense"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["SISTEMA DE COMBATE A INCÊNDIO UTILIZANDO A TECNOLOGIA DE ÁGUA NEBULIZADA (WATER MIST) EM INSTALAÇÕES OFFSHORE"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["FIRE FIGHTING SYSTEM USING THE WATER FOG (WATER MIST) OFFSHORE FACILITIES TECHNOLOGY"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mainier, Fernando Benedicto"],"dc:contributor.committeemember":["Lima, Gilson Brito Alves","Gomes, Paulo Alcantara"],"dc:creator":["Costa Neto, Felicio Pedro da"],"dc:date.accessioned":["2021-03-10T20:47:02Z"],"dc:date.available":["2011-07-07","2021-03-10T20:47:02Z"],"dc:date.issued":["2008-11-24"],"dc:description.abstract":["Offshore rigs and petroleum production units usually require some fire protection and they have many compartments to protect. Water mist system is one among the fire fighting systems available. The water mist system is suitable for liquids fire (class B), solid fuels fire (class A) and electric equipments (class C). It uses small water droplets for fire extinction, suppression and fire control. Test protocols were developed by International Maritime Organization (I.M.O.) aside with National Fire Protection Association (NFPA). These institutions emitted in 2001 the standard NFPA 750 Standard on Water Mist Fire Protection. These protocols and the standard are references for design developments and tests and are used by companies worldwide. This paper proposes to spread the water mist technology, exploiting its operation mechanisms, its application on offshore rigs and petroleum production units, stressing the test of this technology on electric panels.","Em geral toda instalação offshore requer de alguma forma de proteção contra incêndio e há muitos compartimentos a serem protegidos e um dos meios de proteção que pode ser utilizado é o Sistema de Combate a Incêndio com Água Nebulizada (Water Mist). O Sistema de Proteção com Água Nebulizada (Water Mist) é um sistema que tem a capacidade de combater incêndios em líquidos combustíveis e inflamáveis (Classe B), incêndios em combustíveis sólidos (Classe A) e em equipamentos elétricos (Classe C); utilizando a água em forma de pequenas gotas para realizar a extinção, supressão e o controle do incêndio. Protocolos de testes foram desenvolvidos pelo International Maritime Organization (I.M.O.) juntamente com a National Fire Protection Association, que emitiu em 2001 o padrão, NFPA 750 - Standard on Water Mist Fire Protection. Estes protocolos e o padrão são as referências para o desenvolvimento de projetos, testes e são utilizados pelas empresas em todo o mundo. A presente dissertação propõe divulgar a tecnologia de água nebulizada (Water Mist), explorando os seus mecanismos de atuação, sua aplicabilidade em unidade de perfuração e produção offshore de petróleo, tendo como principal motivo o teste da tecnologia em painéis elétricos."],"dc:description.sponsorship":["Universidade Federal Fluminense"],"dc:format":["application/pdf"],"dc:identifier.uri":["https://app.uff.br/riuff/handle/1/19294"],"dc:language":["por"],"dc:publisher.department":["Segurança do Trabalho, Meio-ambiente, Gestão pela Qualidade Total"],"dc:publisher.program":["Programa de Pós-graduação em Sistemas de Gestão"],"dc:rights":["Acesso Aberto"],"dc:rights.license":["CC-BY-SA"],"dc:subject":["Water Mist. Incêndio","Bicos Aspersores","Agente Extintor","Water Mist","Fire","Nozzle","Extinguishing Agent"],"dc:subject.cnpq":["CNPQ::ENGENHARIAS::ENGENHARIA DE PRODUCAO"],"dc:title":["SISTEMA DE COMBATE A INCÊNDIO UTILIZANDO A TECNOLOGIA DE ÁGUA NEBULIZADA (WATER MIST) EM INSTALAÇÕES OFFSHORE"],"dc:title.alternative":["FIRE FIGHTING SYSTEM USING THE WATER FOG (WATER MIST) OFFSHORE FACILITIES TECHNOLOGY"],"dc:type":["Dissertação"],"person:identifier.lattes":["http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4707002D6","http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4791172A4&dataRevisao=null"]},"updated_at":"2026-11-26T20:40:31Z"}