{"id":{"repo_id":"brazil-uff","oai_identifier":"oai:app.uff.br:1/20316"},"canonical_url":"https://search.ndltd.org/etd/brazil-uff/oai:app.uff.br:1/20316","repository":{"repo_id":"brazil-uff","name":"Brazil UFF","base_url":"https://app.uff.br/oai/request"},"display":{"title":"Torque de inserção e força de arrancamento de mini-implantes ortodônticos","abstract":"Introduction: Different configurations of mini-implants screw can influence the torque of insertion, the pullout strength and consequently, the primary stability. The objective was to evaluate the insertion torque and pullout strength of five types of mini-implants. Material and Method: Were obtained images of the mini-implants active points (STEMI 2000-C and MEV) and analyzed by the Axio Vision program (Zeiss, Jena, Germany). Five mini-implants in each group: NEO(Neodent), SIN, CON (Connection), DEN (Dentaurum) and RMO were inserted into porcine rib and the insertion torque recorded by the Lutron 101 software. The tensile test was carried out in the Universal Machine Emic DL 10000 (100kgf/0.05mm/sec). Results: The torque of insertion ranged from 6.40 Ncm to 14.60 Ncm, with a statistically significant difference between groups and RMO DEN, and DEN, CON, NEO and CON; and NEO and RMO. The pullout strength ranged between 136.45 N and 227.30 N, and there was no statistically significant difference between groups. Conclusions: Different mini implants showed active spikes with different characteristics. The torque of insertion was directly proportional to the number of threads and inversely to the fillet angle and bottom of the threads (p<0.05). The structural features of mini-implants did not affect the pullout strength, with no difference between groups (p> 0.05).","abstract_html":"Introduction: Different configurations of mini-implants screw can influence the torque of insertion, the pullout strength and consequently, the primary stability. The objective was to evaluate the insertion torque and pullout strength of five types of mini-implants. Material and Method: Were obtained images of the mini-implants active points (STEMI 2000-C and MEV) and analyzed by the Axio Vision program (Zeiss, Jena, Germany). Five mini-implants in each group: NEO(Neodent), SIN, CON (Connection), DEN (Dentaurum) and RMO were inserted into porcine rib and the insertion torque recorded by the Lutron 101 software. The tensile test was carried out in the Universal Machine Emic DL 10000 (100kgf/0.05mm/sec). Results: The torque of insertion ranged from 6.40 Ncm to 14.60 Ncm, with a statistically significant difference between groups and RMO DEN, and DEN, CON, NEO and CON; and NEO and RMO. The pullout strength ranged between 136.45 N and 227.30 N, and there was no statistically significant difference between groups. Conclusions: Different mini implants showed active spikes with different characteristics. The torque of insertion was directly proportional to the number of threads and inversely to the fillet angle and bottom of the threads (p&lt;0.05). The structural features of mini-implants did not affect the pullout strength, with no difference between groups (p&gt; 0.05).","abstract_has_math":false,"creators":["Kitahara-céia, Flávia Mitiko Fernandes"],"institution":"Programa de Pós-graduação em Odontologia","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Mucha, José Nelson","Elias, Carlos Nelson"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-01-02","date_published":"2009-01-02","updated_at":"2026-11-26T20:40:27Z","subjects":["Implantação Dentária","Dental Implantation"],"languages":["por"],"rights":["Acesso Aberto"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.lattes","label":"Lattes CV","values":["http://lattes.cnpq.br/2233748376817883","http://lattes.cnpq.br/3974126320534425","http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4780835D8"],"render_values":[{"text":"http://lattes.cnpq.br/2233748376817883","href":"http://lattes.cnpq.br/2233748376817883","code":true},{"text":"http://lattes.cnpq.br/3974126320534425","href":"http://lattes.cnpq.br/3974126320534425","code":true},{"text":"http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4780835D8","href":"http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4780835D8","code":true}]}]},"links":{"outbound_url":"https://app.uff.br/riuff/handle/1/20316","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://app.uff.br/riuff/handle/1/20316","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrazil-uff%3Aoai%3Aapp.uff.br%3A1%2F20316","prefix":"oai_dc"},"source_record":{"url":"https://app.uff.br/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aapp.uff.br%3A1%2F20316","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mucha, José Nelson","Elias, Carlos Nelson"]},{"key":"dc:creator","label":"Author","values":["Kitahara-céia, Flávia Mitiko Fernandes"]},{"key":"person:identifier.lattes","label":"Lattes CV","values":["http://lattes.cnpq.br/2233748376817883","http://lattes.cnpq.br/3974126320534425","http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4780835D8"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-03-10T20:49:53Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-10-30","2021-03-10T20:49:53Z"]},{"key":"dc:date.issued","label":"Date","values":["2009-01-02"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Clínica Odontológica"]},{"key":"dc:publisher.program","label":"Dc Publisher Program","values":["Programa de Pós-graduação em Odontologia"]},{"key":"dc:type","label":"Dc Type","values":["Dissertação"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Implantação Dentária","Dental Implantation"]},{"key":"dc:subject.cnpq","label":"Dc Subject Cnpq","values":["CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["por"]},{"key":"dc:rights","label":"Dc Rights","values":["Acesso Aberto"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["CC-BY-SA"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://app.uff.br/riuff/handle/1/20316"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Introduction: Different configurations of mini-implants screw can influence the torque of insertion, the pullout strength and consequently, the primary stability. The objective was to evaluate the insertion torque and pullout strength of five types of mini-implants. Material and Method: Were obtained images of the mini-implants active points (STEMI 2000-C and MEV) and analyzed by the Axio Vision program (Zeiss, Jena, Germany). Five mini-implants in each group: NEO(Neodent), SIN, CON (Connection), DEN (Dentaurum) and RMO were inserted into porcine rib and the insertion torque recorded by the Lutron 101 software. The tensile test was carried out in the Universal Machine Emic DL 10000 (100kgf/0.05mm/sec). Results: The torque of insertion ranged from 6.40 Ncm to 14.60 Ncm, with a statistically significant difference between groups and RMO DEN, and DEN, CON, NEO and CON; and NEO and RMO. The pullout strength ranged between 136.45 N and 227.30 N, and there was no statistically significant difference between groups. Conclusions: Different mini implants showed active spikes with different characteristics. The torque of insertion was directly proportional to the number of threads and inversely to the fillet angle and bottom of the threads (p<0.05). The structural features of mini-implants did not affect the pullout strength, with no difference between groups (p> 0.05).","Introdução: Diferentes configurações de filete de mini-implantes podem influenciar no torque de inserção, na força de arrancamento e conseqüentemente, na estabilidade primária. Objetivou-se avaliar torque de inserção e força de arrancamento de cinco tipos de mini-implantes. Material e Método: Foram obtidas imagens das pontas ativas dos mini-implantes (Stemi 2000-C e do MEV) e analisadas através do programa Axio Vision (Zeiss, Jena, Alemanha). Cinco mini-implantes de cada grupo (Neodent-NEO, SIN, Conexão-CON, Dentaurum-DEN e RMO) foram inseridos em costela suína e o torque de inserção registrado pelo programa Lutron 101. O ensaio à tração foi realizado em máquina Universal Emic DL 10000 (100kgf/0,05mm/seg). Resultados: O torque de inserção variou de 6,40Ncm a 14,60Ncm, com diferença estatisticamente significativa entre os grupos DEN e RMO; DEN e CON; NEO e CON e; NEO e RMO. A força de arrancamento variou entre 136,45N e 227,30N, não houve diferença estatisticamente significativa entre os grupos. Conclusões: Diferentes mini-implantes apresentaram pontas ativas com características distintas. O torque de inserção se mostrou diretamente proporcional ao número de filetes e inversamente ao passo, ângulo e fundo do filete (p<0,05). As características estruturais dos mini-implantes não influenciaram na força de arrancamento, não havendo diferença entre os grupos (p>0,05)."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Torque de inserção e força de arrancamento de mini-implantes ortodônticos"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["The insertion torque and pullout strength of orthodontic mini-implants"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mucha, José Nelson","Elias, Carlos Nelson"],"dc:creator":["Kitahara-céia, Flávia Mitiko Fernandes"],"dc:date.accessioned":["2021-03-10T20:49:53Z"],"dc:date.available":["2013-10-30","2021-03-10T20:49:53Z"],"dc:date.issued":["2009-01-02"],"dc:description.abstract":["Introduction: Different configurations of mini-implants screw can influence the torque of insertion, the pullout strength and consequently, the primary stability. The objective was to evaluate the insertion torque and pullout strength of five types of mini-implants. Material and Method: Were obtained images of the mini-implants active points (STEMI 2000-C and MEV) and analyzed by the Axio Vision program (Zeiss, Jena, Germany). Five mini-implants in each group: NEO(Neodent), SIN, CON (Connection), DEN (Dentaurum) and RMO were inserted into porcine rib and the insertion torque recorded by the Lutron 101 software. The tensile test was carried out in the Universal Machine Emic DL 10000 (100kgf/0.05mm/sec). Results: The torque of insertion ranged from 6.40 Ncm to 14.60 Ncm, with a statistically significant difference between groups and RMO DEN, and DEN, CON, NEO and CON; and NEO and RMO. The pullout strength ranged between 136.45 N and 227.30 N, and there was no statistically significant difference between groups. Conclusions: Different mini implants showed active spikes with different characteristics. The torque of insertion was directly proportional to the number of threads and inversely to the fillet angle and bottom of the threads (p<0.05). The structural features of mini-implants did not affect the pullout strength, with no difference between groups (p> 0.05).","Introdução: Diferentes configurações de filete de mini-implantes podem influenciar no torque de inserção, na força de arrancamento e conseqüentemente, na estabilidade primária. Objetivou-se avaliar torque de inserção e força de arrancamento de cinco tipos de mini-implantes. Material e Método: Foram obtidas imagens das pontas ativas dos mini-implantes (Stemi 2000-C e do MEV) e analisadas através do programa Axio Vision (Zeiss, Jena, Alemanha). Cinco mini-implantes de cada grupo (Neodent-NEO, SIN, Conexão-CON, Dentaurum-DEN e RMO) foram inseridos em costela suína e o torque de inserção registrado pelo programa Lutron 101. O ensaio à tração foi realizado em máquina Universal Emic DL 10000 (100kgf/0,05mm/seg). Resultados: O torque de inserção variou de 6,40Ncm a 14,60Ncm, com diferença estatisticamente significativa entre os grupos DEN e RMO; DEN e CON; NEO e CON e; NEO e RMO. A força de arrancamento variou entre 136,45N e 227,30N, não houve diferença estatisticamente significativa entre os grupos. Conclusões: Diferentes mini-implantes apresentaram pontas ativas com características distintas. O torque de inserção se mostrou diretamente proporcional ao número de filetes e inversamente ao passo, ângulo e fundo do filete (p<0,05). As características estruturais dos mini-implantes não influenciaram na força de arrancamento, não havendo diferença entre os grupos (p>0,05)."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://app.uff.br/riuff/handle/1/20316"],"dc:language":["por"],"dc:publisher.department":["Clínica Odontológica"],"dc:publisher.program":["Programa de Pós-graduação em Odontologia"],"dc:rights":["Acesso Aberto"],"dc:rights.license":["CC-BY-SA"],"dc:subject":["Implantação Dentária","Dental Implantation"],"dc:subject.cnpq":["CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA"],"dc:title":["Torque de inserção e força de arrancamento de mini-implantes ortodônticos"],"dc:title.alternative":["The insertion torque and pullout strength of orthodontic mini-implants"],"dc:type":["Dissertação"],"person:identifier.lattes":["http://lattes.cnpq.br/2233748376817883","http://lattes.cnpq.br/3974126320534425","http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4780835D8"]},"updated_at":"2026-11-26T20:40:27Z"}