{"id":{"repo_id":"brazil-uff","oai_identifier":"oai:app.uff.br:1/20775"},"canonical_url":"https://search.ndltd.org/etd/brazil-uff/oai:app.uff.br:1/20775","repository":{"repo_id":"brazil-uff","name":"Brazil UFF","base_url":"https://app.uff.br/oai/request"},"display":{"title":"Efeito de um inibidor de metaloproteinases de matriz MMPs na estabilidade da adesão entre sistemas adesivos e a dentina humana","abstract":"This study aimed at evaluating the effectiveness of a matrix metalloproteinases (MMPs) inhibitor on the stability of the bonding between adhesive systems and human dentin, presenting laser confocal microscopy (LCM) as a new method for topographic analysis of bonding interfaces. Twenty-four molars had their occlusal enamel removed and the dentin surfaces polished with silicon sandpaper 600 to standardize the smear layer. Two adhesive systems were used: Adper Single Bond 2 SB2 (etch and rinsing) and Clearfil SE Bond CSE (self-etching). Four groups were produced (n= 6): C (control): adhesives were applied according to manufacturer s instructions; and Cx: after etch and rinse (SB2) or the application of the self-etching primer (CSE), the surfaces were treated with 2% chlorhexidine digluconate. A block of composite with 5 mm in height was built up on dentin surfaces and the teeth were sectioned in two axis to obtain composite-dentin sticks with &#8776; 0.8 mm2 of cross section. The adhesive systems and the resin composite were photoactivated using a irradiance of 650 mW/cm² (Optilux 501, Demetron Inc., Danburry, USA), checked by a radiometer (Model 100, Demetron Inc., Danburry, USA). Those sticks were stored in distilled water at 37°C and subjected to microtensile bond strength test - &#61549;TBS - (half after 24h and half after 6 months). The failure mode was evaluated in a stereomicroscope and under a LCM. The &#61549;TBS data were subjected to three-way ANOVA (adhesive system x application protocol of aqueous solution of chlorhexidine digluconate x storage period) and Tukey HSD test (&#61537; = 5%). The failure types were evaluated by percentage. For both groups (C and Cx), SB2 showed no significant reduction in &#61549;TBS after 6 months of storage. On the contrary, in group C, CSE showed a statistically significant reduction of &#61549;TBS after 6 months of storage. Moreover, in the group treated with Cx, the CSE showed similar result to SB2, that is, no decrease in &#61549;TBS after 6 months of storage. In relation of the bonding failure type, with exception of CSE adhesive system from Cx group, where was observed 54,55% of adhesive failures after 24h of storage and 76% after 6 months of storage, in the remaining groups the mixed failures were predominant. Excepting CSE adhesive system applied on Cx treated dentin surfaces, all the other groups presented a percentage increase of cohesive failures after 6 months of storage. The LCM topographic analysis allowed the observation of structures like hackles marks and Wallner lines. Therefore, the application of 2% chlorhexidine digluconate was able to maintain the stability of bond strength after 6 months of storage in distilled water.","abstract_html":"This study aimed at evaluating the effectiveness of a matrix metalloproteinases (MMPs) inhibitor on the stability of the bonding between adhesive systems and human dentin, presenting laser confocal microscopy (LCM) as a new method for topographic analysis of bonding interfaces. Twenty-four molars had their occlusal enamel removed and the dentin surfaces polished with silicon sandpaper 600 to standardize the smear layer. Two adhesive systems were used: Adper Single Bond 2 SB2 (etch and rinsing) and Clearfil SE Bond CSE (self-etching). Four groups were produced (n= 6): C (control): adhesives were applied according to manufacturer s instructions; and Cx: after etch and rinse (SB2) or the application of the self-etching primer (CSE), the surfaces were treated with 2% chlorhexidine digluconate. A block of composite with 5 mm in height was built up on dentin surfaces and the teeth were sectioned in two axis to obtain composite-dentin sticks with &amp;#8776; 0.8 mm2 of cross section. The adhesive systems and the resin composite were photoactivated using a irradiance of 650 mW/cm² (Optilux 501, Demetron Inc., Danburry, USA), checked by a radiometer (Model 100, Demetron Inc., Danburry, USA). Those sticks were stored in distilled water at 37°C and subjected to microtensile bond strength test - &amp;#61549;TBS - (half after 24h and half after 6 months). The failure mode was evaluated in a stereomicroscope and under a LCM. The &amp;#61549;TBS data were subjected to three-way ANOVA (adhesive system x application protocol of aqueous solution of chlorhexidine digluconate x storage period) and Tukey HSD test (&amp;#61537; = 5%). The failure types were evaluated by percentage. For both groups (C and Cx), SB2 showed no significant reduction in &amp;#61549;TBS after 6 months of storage. On the contrary, in group C, CSE showed a statistically significant reduction of &amp;#61549;TBS after 6 months of storage. Moreover, in the group treated with Cx, the CSE showed similar result to SB2, that is, no decrease in &amp;#61549;TBS after 6 months of storage. In relation of the bonding failure type, with exception of CSE adhesive system from Cx group, where was observed 54,55% of adhesive failures after 24h of storage and 76% after 6 months of storage, in the remaining groups the mixed failures were predominant. Excepting CSE adhesive system applied on Cx treated dentin surfaces, all the other groups presented a percentage increase of cohesive failures after 6 months of storage. The LCM topographic analysis allowed the observation of structures like hackles marks and Wallner lines. Therefore, the application of 2% chlorhexidine digluconate was able to maintain the stability of bond strength after 6 months of storage in distilled water.","abstract_has_math":false,"creators":["Brandão, Natasha Lamêgo"],"institution":"Programa de Pós-graduação em Odontologia","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Silva, Eduardo Moreira da"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-01-02","date_published":"2012-01-02","updated_at":"2026-11-26T20:40:08Z","subjects":["Dentina","Adesivos Dentinários","Clorexidina","Dentin","Dentin-Bonding Agents","Chlorhexidine"],"languages":["por"],"rights":["Acesso Aberto"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.lattes","label":"Lattes CV","values":["http://lattes.cnpq.br/5182521524397318","http://lattes.cnpq.br/0084980191573168"],"render_values":[{"text":"http://lattes.cnpq.br/5182521524397318","href":"http://lattes.cnpq.br/5182521524397318","code":true},{"text":"http://lattes.cnpq.br/0084980191573168","href":"http://lattes.cnpq.br/0084980191573168","code":true}]}]},"links":{"outbound_url":"https://app.uff.br/riuff/handle/1/20775","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://app.uff.br/riuff/handle/1/20775","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrazil-uff%3Aoai%3Aapp.uff.br%3A1%2F20775","prefix":"oai_dc"},"source_record":{"url":"https://app.uff.br/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aapp.uff.br%3A1%2F20775","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Silva, Eduardo Moreira da"]},{"key":"dc:creator","label":"Author","values":["Brandão, Natasha Lamêgo"]},{"key":"person:identifier.lattes","label":"Lattes CV","values":["http://lattes.cnpq.br/5182521524397318","http://lattes.cnpq.br/0084980191573168"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-03-10T20:51:09Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-04-14","2021-03-10T20:51:09Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-01-02"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Clínica Odontológica"]},{"key":"dc:publisher.program","label":"Dc Publisher Program","values":["Programa de Pós-graduação em Odontologia"]},{"key":"dc:type","label":"Dc Type","values":["Dissertação"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentina","Adesivos Dentinários","Clorexidina","Dentin","Dentin-Bonding Agents","Chlorhexidine"]},{"key":"dc:subject.cnpq","label":"Dc Subject Cnpq","values":["CNPQ::CIENCIAS DA SAUDE"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["por"]},{"key":"dc:rights","label":"Dc Rights","values":["Acesso Aberto"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["CC-BY-SA"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://app.uff.br/riuff/handle/1/20775"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study aimed at evaluating the effectiveness of a matrix metalloproteinases (MMPs) inhibitor on the stability of the bonding between adhesive systems and human dentin, presenting laser confocal microscopy (LCM) as a new method for topographic analysis of bonding interfaces. Twenty-four molars had their occlusal enamel removed and the dentin surfaces polished with silicon sandpaper 600 to standardize the smear layer. Two adhesive systems were used: Adper Single Bond 2 SB2 (etch and rinsing) and Clearfil SE Bond CSE (self-etching). Four groups were produced (n= 6): C (control): adhesives were applied according to manufacturer s instructions; and Cx: after etch and rinse (SB2) or the application of the self-etching primer (CSE), the surfaces were treated with 2% chlorhexidine digluconate. A block of composite with 5 mm in height was built up on dentin surfaces and the teeth were sectioned in two axis to obtain composite-dentin sticks with &#8776; 0.8 mm2 of cross section. The adhesive systems and the resin composite were photoactivated using a irradiance of 650 mW/cm² (Optilux 501, Demetron Inc., Danburry, USA), checked by a radiometer (Model 100, Demetron Inc., Danburry, USA). Those sticks were stored in distilled water at 37°C and subjected to microtensile bond strength test - &#61549;TBS - (half after 24h and half after 6 months). The failure mode was evaluated in a stereomicroscope and under a LCM. The &#61549;TBS data were subjected to three-way ANOVA (adhesive system x application protocol of aqueous solution of chlorhexidine digluconate x storage period) and Tukey HSD test (&#61537; = 5%). The failure types were evaluated by percentage. For both groups (C and Cx), SB2 showed no significant reduction in &#61549;TBS after 6 months of storage. On the contrary, in group C, CSE showed a statistically significant reduction of &#61549;TBS after 6 months of storage. Moreover, in the group treated with Cx, the CSE showed similar result to SB2, that is, no decrease in &#61549;TBS after 6 months of storage. In relation of the bonding failure type, with exception of CSE adhesive system from Cx group, where was observed 54,55% of adhesive failures after 24h of storage and 76% after 6 months of storage, in the remaining groups the mixed failures were predominant. Excepting CSE adhesive system applied on Cx treated dentin surfaces, all the other groups presented a percentage increase of cohesive failures after 6 months of storage. The LCM topographic analysis allowed the observation of structures like hackles marks and Wallner lines. Therefore, the application of 2% chlorhexidine digluconate was able to maintain the stability of bond strength after 6 months of storage in distilled water.","O objetivo deste estudo foi avaliar a efetividade de um inibidor de metaloproteinases de matriz (MMPs) na estabilidade da adesão entre sistemas adesivos e a dentina humana, apresentando a microscopia confocal a laser (MCL) como um novo método para a análise topográfica das interfaces de união. Vinte e quatro molares tiveram o esmalte oclusal removido e as superfícies de dentina lixadas com lixas de carbeto de silício 600 para padronização da smear layer. Dois sistemas adesivos foram avaliados: Adper Single Bond 2 SB2 (convencional) e Clearfil SE Bond CSE (autocondicionante). Foram produzidos quatro grupos (n= 6): C (controle): os adesivos foram aplicados de acordo com as recomendações dos fabricantes e Cx: após o condicionamento ácido (SB2) ou aplicação do primer autocondicionante (CSE) as superfícies de dentina foram tratadas com digluconato de clorexidina a 2% (Cx). Após a construção de um bloco de compósito de 5 mm de altura sobre as superfícies dentinárias, os dentes foram seccionados em dois eixos até a obtenção de palitos de dentina-compósito com &#8776; 0,8 mm2 de seção transversal. Para a fotoativação dos sistemas adesivos e dos incrementos de compósito, foi utilizada uma irradiância de 650 mW/cm2 (Optilux 501, Demetron Inc., Danburry, USA), verificada com radiômetro (Modelo 100, Demetron Inc., Danburry, USA). Os palitos foram armazenados em água destilada a 37°C e submetidos a teste de resistência de união por ensaio de microtração - R&#61549;T - (metade após 24h e a outra metade após 6 meses). O tipo de falha foi avaliada em estereomicroscópio e por meio de MCL. Os dados de R&#61549;T foram submetidos à análise de variância de três fatores (sistema adesivo x protocolo de aplicação da solução aquosa de digluconato de clorexidina x tempo de armazenagem) e ao teste de Tukey HSD (&#61537; = 5%). Os tipos de falha foram avaliados percentualmente. Tanto para o grupo C como para o tratado com Cx, o SB2 não apresentou redução significante da R&#61549;T após 6 meses de imersão. Diferentemente, no grupo C, o CSE apresentou redução estatisticamente significante da R&#61549;T após 6 meses de imersão. Por outro lado, no grupo tratado com Cx, o adesivo CSE apresentou comportamento semelhante ao SB2, ou seja, não houve diminuição da R&#61549;T. Em relação ao tipo de falha da interface de união, com exceção do adesivo CSE no grupo tratado com digluconato de clorexidina, onde foi observado um percentual de 54,55% de falhas adesivas após 24h de imersão e 76% após 6 meses, nos demais grupos houve preponderância de falhas mistas na interface de união. Exceto o adesivo CSE aplicado em superfícies dentinárias tratadas com Cx, todos os demais grupos apresentaram um aumento percentual de falhas coesivas após 6 meses de imersão. A análise topográfica em MCL permitiu a observação de estruturas tipo cristas de galo (hackles) e linhas de arrasto. Com base nisso, concluiu-se que a aplicação de digluconato de clorexidina a 2% foi capaz de manter a estabilidade da resistência de união após 6 meses de imersão."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Efeito de um inibidor de metaloproteinases de matriz MMPs na estabilidade da adesão entre sistemas adesivos e a dentina humana"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Effect of a matrix metalloproteinases MMPs inhibitor on the stability of adhesion between adhesive systems and human dentin"]}]}],"canonical_facts":{"dc:contributor.advisor":["Silva, Eduardo Moreira da"],"dc:creator":["Brandão, Natasha Lamêgo"],"dc:date.accessioned":["2021-03-10T20:51:09Z"],"dc:date.available":["2015-04-14","2021-03-10T20:51:09Z"],"dc:date.issued":["2012-01-02"],"dc:description.abstract":["This study aimed at evaluating the effectiveness of a matrix metalloproteinases (MMPs) inhibitor on the stability of the bonding between adhesive systems and human dentin, presenting laser confocal microscopy (LCM) as a new method for topographic analysis of bonding interfaces. Twenty-four molars had their occlusal enamel removed and the dentin surfaces polished with silicon sandpaper 600 to standardize the smear layer. Two adhesive systems were used: Adper Single Bond 2 SB2 (etch and rinsing) and Clearfil SE Bond CSE (self-etching). Four groups were produced (n= 6): C (control): adhesives were applied according to manufacturer s instructions; and Cx: after etch and rinse (SB2) or the application of the self-etching primer (CSE), the surfaces were treated with 2% chlorhexidine digluconate. A block of composite with 5 mm in height was built up on dentin surfaces and the teeth were sectioned in two axis to obtain composite-dentin sticks with &#8776; 0.8 mm2 of cross section. The adhesive systems and the resin composite were photoactivated using a irradiance of 650 mW/cm² (Optilux 501, Demetron Inc., Danburry, USA), checked by a radiometer (Model 100, Demetron Inc., Danburry, USA). Those sticks were stored in distilled water at 37°C and subjected to microtensile bond strength test - &#61549;TBS - (half after 24h and half after 6 months). The failure mode was evaluated in a stereomicroscope and under a LCM. The &#61549;TBS data were subjected to three-way ANOVA (adhesive system x application protocol of aqueous solution of chlorhexidine digluconate x storage period) and Tukey HSD test (&#61537; = 5%). The failure types were evaluated by percentage. For both groups (C and Cx), SB2 showed no significant reduction in &#61549;TBS after 6 months of storage. On the contrary, in group C, CSE showed a statistically significant reduction of &#61549;TBS after 6 months of storage. Moreover, in the group treated with Cx, the CSE showed similar result to SB2, that is, no decrease in &#61549;TBS after 6 months of storage. In relation of the bonding failure type, with exception of CSE adhesive system from Cx group, where was observed 54,55% of adhesive failures after 24h of storage and 76% after 6 months of storage, in the remaining groups the mixed failures were predominant. Excepting CSE adhesive system applied on Cx treated dentin surfaces, all the other groups presented a percentage increase of cohesive failures after 6 months of storage. The LCM topographic analysis allowed the observation of structures like hackles marks and Wallner lines. Therefore, the application of 2% chlorhexidine digluconate was able to maintain the stability of bond strength after 6 months of storage in distilled water.","O objetivo deste estudo foi avaliar a efetividade de um inibidor de metaloproteinases de matriz (MMPs) na estabilidade da adesão entre sistemas adesivos e a dentina humana, apresentando a microscopia confocal a laser (MCL) como um novo método para a análise topográfica das interfaces de união. Vinte e quatro molares tiveram o esmalte oclusal removido e as superfícies de dentina lixadas com lixas de carbeto de silício 600 para padronização da smear layer. Dois sistemas adesivos foram avaliados: Adper Single Bond 2 SB2 (convencional) e Clearfil SE Bond CSE (autocondicionante). Foram produzidos quatro grupos (n= 6): C (controle): os adesivos foram aplicados de acordo com as recomendações dos fabricantes e Cx: após o condicionamento ácido (SB2) ou aplicação do primer autocondicionante (CSE) as superfícies de dentina foram tratadas com digluconato de clorexidina a 2% (Cx). Após a construção de um bloco de compósito de 5 mm de altura sobre as superfícies dentinárias, os dentes foram seccionados em dois eixos até a obtenção de palitos de dentina-compósito com &#8776; 0,8 mm2 de seção transversal. Para a fotoativação dos sistemas adesivos e dos incrementos de compósito, foi utilizada uma irradiância de 650 mW/cm2 (Optilux 501, Demetron Inc., Danburry, USA), verificada com radiômetro (Modelo 100, Demetron Inc., Danburry, USA). Os palitos foram armazenados em água destilada a 37°C e submetidos a teste de resistência de união por ensaio de microtração - R&#61549;T - (metade após 24h e a outra metade após 6 meses). O tipo de falha foi avaliada em estereomicroscópio e por meio de MCL. Os dados de R&#61549;T foram submetidos à análise de variância de três fatores (sistema adesivo x protocolo de aplicação da solução aquosa de digluconato de clorexidina x tempo de armazenagem) e ao teste de Tukey HSD (&#61537; = 5%). Os tipos de falha foram avaliados percentualmente. Tanto para o grupo C como para o tratado com Cx, o SB2 não apresentou redução significante da R&#61549;T após 6 meses de imersão. Diferentemente, no grupo C, o CSE apresentou redução estatisticamente significante da R&#61549;T após 6 meses de imersão. Por outro lado, no grupo tratado com Cx, o adesivo CSE apresentou comportamento semelhante ao SB2, ou seja, não houve diminuição da R&#61549;T. Em relação ao tipo de falha da interface de união, com exceção do adesivo CSE no grupo tratado com digluconato de clorexidina, onde foi observado um percentual de 54,55% de falhas adesivas após 24h de imersão e 76% após 6 meses, nos demais grupos houve preponderância de falhas mistas na interface de união. Exceto o adesivo CSE aplicado em superfícies dentinárias tratadas com Cx, todos os demais grupos apresentaram um aumento percentual de falhas coesivas após 6 meses de imersão. A análise topográfica em MCL permitiu a observação de estruturas tipo cristas de galo (hackles) e linhas de arrasto. Com base nisso, concluiu-se que a aplicação de digluconato de clorexidina a 2% foi capaz de manter a estabilidade da resistência de união após 6 meses de imersão."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://app.uff.br/riuff/handle/1/20775"],"dc:language":["por"],"dc:publisher.department":["Clínica Odontológica"],"dc:publisher.program":["Programa de Pós-graduação em Odontologia"],"dc:rights":["Acesso Aberto"],"dc:rights.license":["CC-BY-SA"],"dc:subject":["Dentina","Adesivos Dentinários","Clorexidina","Dentin","Dentin-Bonding Agents","Chlorhexidine"],"dc:subject.cnpq":["CNPQ::CIENCIAS DA SAUDE"],"dc:title":["Efeito de um inibidor de metaloproteinases de matriz MMPs na estabilidade da adesão entre sistemas adesivos e a dentina humana"],"dc:title.alternative":["Effect of a matrix metalloproteinases MMPs inhibitor on the stability of adhesion between adhesive systems and human dentin"],"dc:type":["Dissertação"],"person:identifier.lattes":["http://lattes.cnpq.br/5182521524397318","http://lattes.cnpq.br/0084980191573168"]},"updated_at":"2026-11-26T20:40:08Z"}