{"id":{"repo_id":"brazil-uff","oai_identifier":"oai:app.uff.br:1/20806"},"canonical_url":"https://search.ndltd.org/etd/brazil-uff/oai:app.uff.br:1/20806","repository":{"repo_id":"brazil-uff","name":"Brazil UFF","base_url":"https://app.uff.br/oai/request"},"display":{"title":"Análise de fatores críticos de sucesso na gestão de segurança em atividades de manutenção de linha viva em transmissão em ultra-alta tensão","abstract":"The increasing energy demand in the domestic market in recent decades led the Brazilian government to encourage technical and scientific order that they were defined alternatives to transmission large blocks of power over long distances (more than two thousand kilometers), interconnecting the big huge potential in certain localities watersheds of northern Brazil to the larger consumer centers located in other regions of this country either through specific lines and / or connecting to the national grid. After making various technical feasibility studies based on the existing literature, experiences of other countries and considering the technical and environmental specificities of our country of continental dimensions, the Brazilian government has chosen to introduce the technology of ultra high voltage transmission, which includes the alternating or direct current transmission. In the case of Brazil, it will start with the transmission in Direct Current. The entry in operation here in Brazil of innovative technologies for the transmission of electric energy in ultra high voltage levels brings, beyond traditional technology to industry and society gains technical questions and the general public about risks pertaining to safety and health at work, as well as the community and the surrounding areas. The present work has the objective to identify and analyze the critical success factors in the maintenance of overhead energized transmission lines ( lifeline ) at levels of ultra-high voltage activities (greater than 600 kV in Direct Current and greater than 750 kV in Alternating Current). As for specific goals, relate to the risks and factors referred to how the technological aspects, human resources, safety and logical/laboratory testing support. The methodological approach chosen is, after identification of the relevant theoretical framework at the national and international level, a questionnaire was sent via e-mail from both academia as public and private companies in the Brazilian electric sector and technical analysis in context with the aid of a specific program (search tool). The main findings regarding safety in maintenance tasks on air energized transmission lines ( lifeline ) in extra-high voltages levels and designed for ultra high voltages emphasize the need to maintain tight control of the means of access (scaled and shift) to carry out work to the potential proper and systematic use of individual and collective protective equipment, monitoring of parameters of occupational exposure to electric, magnetic and electromagnetic fields, as well as reconciling design geometry structure (towers) to the collection of experiences field in terms of perceived risk and operational difficulties reported by maintenance crews","abstract_html":"The increasing energy demand in the domestic market in recent decades led the Brazilian government to encourage technical and scientific order that they were defined alternatives to transmission large blocks of power over long distances (more than two thousand kilometers), interconnecting the big huge potential in certain localities watersheds of northern Brazil to the larger consumer centers located in other regions of this country either through specific lines and / or connecting to the national grid. After making various technical feasibility studies based on the existing literature, experiences of other countries and considering the technical and environmental specificities of our country of continental dimensions, the Brazilian government has chosen to introduce the technology of ultra high voltage transmission, which includes the alternating or direct current transmission. In the case of Brazil, it will start with the transmission in Direct Current. The entry in operation here in Brazil of innovative technologies for the transmission of electric energy in ultra high voltage levels brings, beyond traditional technology to industry and society gains technical questions and the general public about risks pertaining to safety and health at work, as well as the community and the surrounding areas. The present work has the objective to identify and analyze the critical success factors in the maintenance of overhead energized transmission lines ( lifeline ) at levels of ultra-high voltage activities (greater than 600 kV in Direct Current and greater than 750 kV in Alternating Current). As for specific goals, relate to the risks and factors referred to how the technological aspects, human resources, safety and logical/laboratory testing support. The methodological approach chosen is, after identification of the relevant theoretical framework at the national and international level, a questionnaire was sent via e-mail from both academia as public and private companies in the Brazilian electric sector and technical analysis in context with the aid of a specific program (search tool). The main findings regarding safety in maintenance tasks on air energized transmission lines ( lifeline ) in extra-high voltages levels and designed for ultra high voltages emphasize the need to maintain tight control of the means of access (scaled and shift) to carry out work to the potential proper and systematic use of individual and collective protective equipment, monitoring of parameters of occupational exposure to electric, magnetic and electromagnetic fields, as well as reconciling design geometry structure (towers) to the collection of experiences field in terms of perceived risk and operational difficulties reported by maintenance crews","abstract_has_math":false,"creators":["Leitão, Gerardo Luiz Garcia"],"institution":"Programa de Pós-graduação em Sistemas de Gestão","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Lima, Gilson Brito Alves"],"committee_chairs":[],"committee_members":["Tavares, Geraldo Martins","Salari Filho, João Clavio"],"year":2014,"date_issued":"2014-04-29","date_published":"2014-04-29","updated_at":"2026-11-26T19:47:15Z","subjects":["Ultra Alta Tensão","Linhas de transmissão","Manutenção de linha viva","Ultra high voltage","Transmission lines","Live maintenance"],"languages":["por"],"rights":["Acesso Aberto"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.lattes","label":"Lattes CV","values":["http://lattes.cnpq.br/3610089127627323","http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4791172A4&dataRevisao=null","http://lattes.cnpq.br/8533149267106175"],"render_values":[{"text":"http://lattes.cnpq.br/3610089127627323","href":"http://lattes.cnpq.br/3610089127627323","code":true},{"text":"http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4791172A4&dataRevisao=null","href":"http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4791172A4&dataRevisao=null","code":true},{"text":"http://lattes.cnpq.br/8533149267106175","href":"http://lattes.cnpq.br/8533149267106175","code":true}]}]},"links":{"outbound_url":"https://app.uff.br/riuff/handle/1/20806","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://app.uff.br/riuff/handle/1/20806","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrazil-uff%3Aoai%3Aapp.uff.br%3A1%2F20806","prefix":"oai_dc"},"source_record":{"url":"https://app.uff.br/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aapp.uff.br%3A1%2F20806","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lima, Gilson Brito Alves"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Tavares, Geraldo Martins","Salari Filho, João Clavio"]},{"key":"dc:creator","label":"Author","values":["Leitão, Gerardo Luiz Garcia"]},{"key":"person:identifier.lattes","label":"Lattes CV","values":["http://lattes.cnpq.br/3610089127627323","http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4791172A4&dataRevisao=null","http://lattes.cnpq.br/8533149267106175"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-03-10T20:51:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-07-10","2021-03-10T20:51:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-04-29"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Segurança do Trabalho, Meio-ambiente, Gestão pela Qualidade Total"]},{"key":"dc:publisher.program","label":"Dc Publisher Program","values":["Programa de Pós-graduação em Sistemas de Gestão"]},{"key":"dc:type","label":"Dc Type","values":["Dissertação"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ultra Alta Tensão","Linhas de transmissão","Manutenção de linha viva","Ultra high voltage","Transmission lines","Live maintenance"]},{"key":"dc:subject.cnpq","label":"Dc Subject Cnpq","values":["CNPQ::ENGENHARIAS::ENGENHARIA DE PRODUCAO"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["por"]},{"key":"dc:rights","label":"Dc Rights","values":["Acesso Aberto"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["CC-BY-SA"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://app.uff.br/riuff/handle/1/20806"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The increasing energy demand in the domestic market in recent decades led the Brazilian government to encourage technical and scientific order that they were defined alternatives to transmission large blocks of power over long distances (more than two thousand kilometers), interconnecting the big huge potential in certain localities watersheds of northern Brazil to the larger consumer centers located in other regions of this country either through specific lines and / or connecting to the national grid. After making various technical feasibility studies based on the existing literature, experiences of other countries and considering the technical and environmental specificities of our country of continental dimensions, the Brazilian government has chosen to introduce the technology of ultra high voltage transmission, which includes the alternating or direct current transmission. In the case of Brazil, it will start with the transmission in Direct Current. The entry in operation here in Brazil of innovative technologies for the transmission of electric energy in ultra high voltage levels brings, beyond traditional technology to industry and society gains technical questions and the general public about risks pertaining to safety and health at work, as well as the community and the surrounding areas. The present work has the objective to identify and analyze the critical success factors in the maintenance of overhead energized transmission lines ( lifeline ) at levels of ultra-high voltage activities (greater than 600 kV in Direct Current and greater than 750 kV in Alternating Current). As for specific goals, relate to the risks and factors referred to how the technological aspects, human resources, safety and logical/laboratory testing support. The methodological approach chosen is, after identification of the relevant theoretical framework at the national and international level, a questionnaire was sent via e-mail from both academia as public and private companies in the Brazilian electric sector and technical analysis in context with the aid of a specific program (search tool). The main findings regarding safety in maintenance tasks on air energized transmission lines ( lifeline ) in extra-high voltages levels and designed for ultra high voltages emphasize the need to maintain tight control of the means of access (scaled and shift) to carry out work to the potential proper and systematic use of individual and collective protective equipment, monitoring of parameters of occupational exposure to electric, magnetic and electromagnetic fields, as well as reconciling design geometry structure (towers) to the collection of experiences field in terms of perceived risk and operational difficulties reported by maintenance crews","Demandas energéticas do mercado interno brasileiro motivaram a realização de estudos técnicos para definição de alternativas de transmissão de energia elétrica a longas distâncias (mais de 2.500 km). Após realização de estudos de viabilidade, o governo brasileiro optou por adotar a tecnologia de transmissão em níveis de ultra alta tensão, inicialmente em corrente contínua e, futuramente, em corrente alternada. Paralelamente aos estudos técnicos, encontra-se em fase final de construção no município de Nova Iguaçu (RJ) um laboratório específico para realização de ensaios elétricos em níveis de ultra alta tensão.O presente trabalho tem por objetivo geral identificar e analisar os fatores críticos de sucesso em atividades de manutenção de linhas aéreas de transmissão de energia elétrica energizadas ( linha viva ), em níveis de ultra alta tensão, isto é maiores que 600 kV em corrente contínua e maiores que 750 kV em corrente alternada. Quanto aos aspectos específicos, relacionam-se os riscos e medidas de controle em termos de fatores críticos de sucesso, sob os seguintes aspectos ( clusters ): operacional, recursos humanos, segurança no trabalho e suporte logístico/ensaios laboratoriais. A abordagem metodológica consiste, após identificação do referencial teórico, na aplicação de um questionário enviado, via correio eletrônico, para especialistas e acadêmicos do setor elétrico brasileiro. A análise contextualizada das respostas dos questionários enfatiza, entre outros itens, a necessidade de se manter um rigoroso controle do modo de acesso (escalada, deslocamentos e descidas) e monitoramento dos valores de campos elétricos e magnéticos. Além disso, para tarefas de manutenção de linha viva ao potencial foi identificada a necessidade de se coletar sistematicamente as experiências, em termos de percepção de risco e dificuldades operacionais relatadas pelas equipes de manutenção"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Análise de fatores críticos de sucesso na gestão de segurança em atividades de manutenção de linha viva em transmissão em ultra-alta tensão"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["\"Ultra-high-voltage transmission lines: analysis of critical success factors for safety management of live-line maintenance work\""]}]}],"canonical_facts":{"dc:contributor.advisor":["Lima, Gilson Brito Alves"],"dc:contributor.committeemember":["Tavares, Geraldo Martins","Salari Filho, João Clavio"],"dc:creator":["Leitão, Gerardo Luiz Garcia"],"dc:date.accessioned":["2021-03-10T20:51:14Z"],"dc:date.available":["2015-07-10","2021-03-10T20:51:14Z"],"dc:date.issued":["2014-04-29"],"dc:description.abstract":["The increasing energy demand in the domestic market in recent decades led the Brazilian government to encourage technical and scientific order that they were defined alternatives to transmission large blocks of power over long distances (more than two thousand kilometers), interconnecting the big huge potential in certain localities watersheds of northern Brazil to the larger consumer centers located in other regions of this country either through specific lines and / or connecting to the national grid. After making various technical feasibility studies based on the existing literature, experiences of other countries and considering the technical and environmental specificities of our country of continental dimensions, the Brazilian government has chosen to introduce the technology of ultra high voltage transmission, which includes the alternating or direct current transmission. In the case of Brazil, it will start with the transmission in Direct Current. The entry in operation here in Brazil of innovative technologies for the transmission of electric energy in ultra high voltage levels brings, beyond traditional technology to industry and society gains technical questions and the general public about risks pertaining to safety and health at work, as well as the community and the surrounding areas. The present work has the objective to identify and analyze the critical success factors in the maintenance of overhead energized transmission lines ( lifeline ) at levels of ultra-high voltage activities (greater than 600 kV in Direct Current and greater than 750 kV in Alternating Current). As for specific goals, relate to the risks and factors referred to how the technological aspects, human resources, safety and logical/laboratory testing support. The methodological approach chosen is, after identification of the relevant theoretical framework at the national and international level, a questionnaire was sent via e-mail from both academia as public and private companies in the Brazilian electric sector and technical analysis in context with the aid of a specific program (search tool). The main findings regarding safety in maintenance tasks on air energized transmission lines ( lifeline ) in extra-high voltages levels and designed for ultra high voltages emphasize the need to maintain tight control of the means of access (scaled and shift) to carry out work to the potential proper and systematic use of individual and collective protective equipment, monitoring of parameters of occupational exposure to electric, magnetic and electromagnetic fields, as well as reconciling design geometry structure (towers) to the collection of experiences field in terms of perceived risk and operational difficulties reported by maintenance crews","Demandas energéticas do mercado interno brasileiro motivaram a realização de estudos técnicos para definição de alternativas de transmissão de energia elétrica a longas distâncias (mais de 2.500 km). Após realização de estudos de viabilidade, o governo brasileiro optou por adotar a tecnologia de transmissão em níveis de ultra alta tensão, inicialmente em corrente contínua e, futuramente, em corrente alternada. Paralelamente aos estudos técnicos, encontra-se em fase final de construção no município de Nova Iguaçu (RJ) um laboratório específico para realização de ensaios elétricos em níveis de ultra alta tensão.O presente trabalho tem por objetivo geral identificar e analisar os fatores críticos de sucesso em atividades de manutenção de linhas aéreas de transmissão de energia elétrica energizadas ( linha viva ), em níveis de ultra alta tensão, isto é maiores que 600 kV em corrente contínua e maiores que 750 kV em corrente alternada. Quanto aos aspectos específicos, relacionam-se os riscos e medidas de controle em termos de fatores críticos de sucesso, sob os seguintes aspectos ( clusters ): operacional, recursos humanos, segurança no trabalho e suporte logístico/ensaios laboratoriais. A abordagem metodológica consiste, após identificação do referencial teórico, na aplicação de um questionário enviado, via correio eletrônico, para especialistas e acadêmicos do setor elétrico brasileiro. A análise contextualizada das respostas dos questionários enfatiza, entre outros itens, a necessidade de se manter um rigoroso controle do modo de acesso (escalada, deslocamentos e descidas) e monitoramento dos valores de campos elétricos e magnéticos. Além disso, para tarefas de manutenção de linha viva ao potencial foi identificada a necessidade de se coletar sistematicamente as experiências, em termos de percepção de risco e dificuldades operacionais relatadas pelas equipes de manutenção"],"dc:format":["application/pdf"],"dc:identifier.uri":["https://app.uff.br/riuff/handle/1/20806"],"dc:language":["por"],"dc:publisher.department":["Segurança do Trabalho, Meio-ambiente, Gestão pela Qualidade Total"],"dc:publisher.program":["Programa de Pós-graduação em Sistemas de Gestão"],"dc:rights":["Acesso Aberto"],"dc:rights.license":["CC-BY-SA"],"dc:subject":["Ultra Alta Tensão","Linhas de transmissão","Manutenção de linha viva","Ultra high voltage","Transmission lines","Live maintenance"],"dc:subject.cnpq":["CNPQ::ENGENHARIAS::ENGENHARIA DE PRODUCAO"],"dc:title":["Análise de fatores críticos de sucesso na gestão de segurança em atividades de manutenção de linha viva em transmissão em ultra-alta tensão"],"dc:title.alternative":["\"Ultra-high-voltage transmission lines: analysis of critical success factors for safety management of live-line maintenance work\""],"dc:type":["Dissertação"],"person:identifier.lattes":["http://lattes.cnpq.br/3610089127627323","http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4791172A4&dataRevisao=null","http://lattes.cnpq.br/8533149267106175"]},"updated_at":"2026-11-26T19:47:15Z"}