{"id":{"repo_id":"brazil-uff","oai_identifier":"oai:app.uff.br:1/20892"},"canonical_url":"https://search.ndltd.org/etd/brazil-uff/oai:app.uff.br:1/20892","repository":{"repo_id":"brazil-uff","name":"Brazil UFF","base_url":"https://app.uff.br/oai/request"},"display":{"title":"AVALIAÇÃO DE MEMBRANAS DE OSMOSE INVERSA NO TRATAMENTO DE ÁGUAS DE PURGA DE TORRES DE REFRIGERAÇÃO DE INDÚSTRIA PETROLÍFERA COM FINALIDADE DE REUSO","abstract":"In the present study the possibility of treatment for reuse of the purge water from the Refinery Duque de Caxias cooling towers by reverse osmosis (RO) was evaluated. The oil industry consumes huge volumes of water in the industrial refining operations and, due to the increasing demands and changes in the environmental legislation, reinforcing the reuse of it, the purge waters present high flows and chemical composition characteristics that make them proper for treatment for reuse. The RO process has two fundamental advantages for desmineralized water production in the industry: to decrease (or even to eliminate) the demand for chemical reagents used in the water treatment; and to reduce the effluent volumes. The characteristics of two commercial RO membranes (RO-1 polyamide and RO-2 cellulose acetate) were studied using a methodology established for this purpose, and the rejections for different chemical species were evaluated in the purge water from cooling towers. In general, rejections of chemical species higher than 90% were obtained with two RO membranes, and the characteristics of the water treated with them were comparable to those obtained with the conventional treatments. There was an increase in the water pH after the treatment using RO, so a final adjustment of the water pH is recommended before its use. The polyamide membrane presented better acting for the treatment of the purge water studied and the results point out the potential of employment of the RO membranes in the treatment of the cooling towers purge water from Refinery Duque de Caxias (Petrobras/Reduc).","abstract_html":"In the present study the possibility of treatment for reuse of the purge water from the Refinery Duque de Caxias cooling towers by reverse osmosis (RO) was evaluated. The oil industry consumes huge volumes of water in the industrial refining operations and, due to the increasing demands and changes in the environmental legislation, reinforcing the reuse of it, the purge waters present high flows and chemical composition characteristics that make them proper for treatment for reuse. The RO process has two fundamental advantages for desmineralized water production in the industry: to decrease (or even to eliminate) the demand for chemical reagents used in the water treatment; and to reduce the effluent volumes. The characteristics of two commercial RO membranes (RO-1 polyamide and RO-2 cellulose acetate) were studied using a methodology established for this purpose, and the rejections for different chemical species were evaluated in the purge water from cooling towers. In general, rejections of chemical species higher than 90% were obtained with two RO membranes, and the characteristics of the water treated with them were comparable to those obtained with the conventional treatments. There was an increase in the water pH after the treatment using RO, so a final adjustment of the water pH is recommended before its use. The polyamide membrane presented better acting for the treatment of the purge water studied and the results point out the potential of employment of the RO membranes in the treatment of the cooling towers purge water from Refinery Duque de Caxias (Petrobras/Reduc).","abstract_has_math":false,"creators":["Nascimento, Jailton Ferreira do"],"institution":"Programa de Pós-graduação em Química","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Netto, Annibal Duarte Pereira","Medeiros, João Alfredo"],"committee_chairs":[],"committee_members":["Barbosa, Celina Cândida Ribeiro","Azevedo, Alexandre Reis de","Cassella, Ricardo Jorgensen"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-26T20:40:29Z","subjects":["Águas de purga","Torres de refrigeração","Indústria petrolífera","Água de reuso","Osmose inversa","Reuso da água","Dessalinização","Poluição ambiental","Waters of purge","Cooling towers","Petroliferous industry","Water of reuse"],"languages":["por"],"rights":["Acesso Aberto"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"person:identifier.lattes","label":"Lattes CV","values":["http://lattes.cnpq.br/5543223323634478","http://lattes.cnpq.br/4914949489265543","http://lattes.cnpq.br/9226448743895474","http://lattes.cnpq.br/8965339627815488"],"render_values":[{"text":"http://lattes.cnpq.br/5543223323634478","href":"http://lattes.cnpq.br/5543223323634478","code":true},{"text":"http://lattes.cnpq.br/4914949489265543","href":"http://lattes.cnpq.br/4914949489265543","code":true},{"text":"http://lattes.cnpq.br/9226448743895474","href":"http://lattes.cnpq.br/9226448743895474","code":true},{"text":"http://lattes.cnpq.br/8965339627815488","href":"http://lattes.cnpq.br/8965339627815488","code":true}]}]},"links":{"outbound_url":"https://app.uff.br/riuff/handle/1/20892","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://app.uff.br/riuff/handle/1/20892","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrazil-uff%3Aoai%3Aapp.uff.br%3A1%2F20892","prefix":"oai_dc"},"source_record":{"url":"https://app.uff.br/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aapp.uff.br%3A1%2F20892","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Netto, Annibal Duarte Pereira","Medeiros, João Alfredo"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Barbosa, Celina Cândida Ribeiro","Azevedo, Alexandre Reis de","Cassella, Ricardo Jorgensen"]},{"key":"dc:creator","label":"Author","values":["Nascimento, Jailton Ferreira do"]},{"key":"person:identifier.lattes","label":"Lattes CV","values":["http://lattes.cnpq.br/5543223323634478","http://lattes.cnpq.br/4914949489265543","http://lattes.cnpq.br/9226448743895474","http://lattes.cnpq.br/8965339627815488"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-03-10T20:51:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-02-01","2021-03-10T20:51:28Z"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Química"]},{"key":"dc:publisher.program","label":"Dc Publisher Program","values":["Programa de Pós-graduação em Química"]},{"key":"dc:type","label":"Dc Type","values":["Dissertação"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Águas de purga","Torres de refrigeração","Indústria petrolífera","Água de reuso","Osmose inversa","Reuso da água","Dessalinização","Poluição ambiental","Waters of purge","Cooling towers","Petroliferous industry","Water of reuse"]},{"key":"dc:subject.cnpq","label":"Dc Subject Cnpq","values":["CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["por"]},{"key":"dc:rights","label":"Dc Rights","values":["Acesso Aberto"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["CC-BY-SA"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://app.uff.br/riuff/handle/1/20892"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In the present study the possibility of treatment for reuse of the purge water from the Refinery Duque de Caxias cooling towers by reverse osmosis (RO) was evaluated. The oil industry consumes huge volumes of water in the industrial refining operations and, due to the increasing demands and changes in the environmental legislation, reinforcing the reuse of it, the purge waters present high flows and chemical composition characteristics that make them proper for treatment for reuse. The RO process has two fundamental advantages for desmineralized water production in the industry: to decrease (or even to eliminate) the demand for chemical reagents used in the water treatment; and to reduce the effluent volumes. The characteristics of two commercial RO membranes (RO-1 polyamide and RO-2 cellulose acetate) were studied using a methodology established for this purpose, and the rejections for different chemical species were evaluated in the purge water from cooling towers. In general, rejections of chemical species higher than 90% were obtained with two RO membranes, and the characteristics of the water treated with them were comparable to those obtained with the conventional treatments. There was an increase in the water pH after the treatment using RO, so a final adjustment of the water pH is recommended before its use. The polyamide membrane presented better acting for the treatment of the purge water studied and the results point out the potential of employment of the RO membranes in the treatment of the cooling towers purge water from Refinery Duque de Caxias (Petrobras/Reduc).","Neste estudo avaliou-se a possibilidade do tratamento das águas de purga das torres de resfriamento por membranas de osmose inversa (OI) da Refinaria Duque de Caxias (Petrobras/Reduc) com finalidade de reuso. A indústria de petróleo consome apreciável quantidade de água nas operações industriais de refino e devido as crescentes exigências e mudanças na legislação ambiental pelo uso da mesma, as águas de purga por apresentarem apreciável vazão e características de composição químicas que as tornam passíveis de tratamento e reuso. O processo de OI possui duas vantagens fundamentais para produção de água desmineralizada em indústrias: reduzir (ou até eliminação) do consumo de reagentes químicos para tratamento de água; e reduzir os volumes de efluentes gerados. As características de duas membranas de OI comerciais (poliamida OI-1 e acetato de celulose OI-2) foram estudadas através de metodologia implementada com esta finalidade e as rejeições para diferentes espécies químicas foram avaliadas na água de purga das torres de resfriamento. De modo geral, rejeições de espécies químicas maiores que 90% foram obtidas com as duas membranas de OI, obtendo-se características comparáveis às da água tratada por métodos convencionais. Após tratamento por OI houve um aumento de pH da água sendo recomendado o ajuste final da mesma antes da sua utilização. A membrana de poliamida apresentou melhor desempenho para o tratamento desta água de purga e os resultados obtidos indicam o potencial de utilização de membranas de OI em tratamento de águas de purga das torres de resfriamento da Refinaria Duque de Caxias (Petrobras/Reduc)."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["AVALIAÇÃO DE MEMBRANAS DE OSMOSE INVERSA NO TRATAMENTO DE ÁGUAS DE PURGA DE TORRES DE REFRIGERAÇÃO DE INDÚSTRIA PETROLÍFERA COM FINALIDADE DE REUSO"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["EVALUATION OF MEMBRANES OF INVERSE OSMOSIS IN THE WATER TREATMENT OF PURGES DE TOWERS OF REFRIGERATION OF PETROLIFEROUS INDUSTRY WITH PURPOSE OF REUSES"]}]}],"canonical_facts":{"dc:contributor.advisor":["Netto, Annibal Duarte Pereira","Medeiros, João Alfredo"],"dc:contributor.committeemember":["Barbosa, Celina Cândida Ribeiro","Azevedo, Alexandre Reis de","Cassella, Ricardo Jorgensen"],"dc:creator":["Nascimento, Jailton Ferreira do"],"dc:date.accessioned":["2021-03-10T20:51:28Z"],"dc:date.available":["2007-02-01","2021-03-10T20:51:28Z"],"dc:description.abstract":["In the present study the possibility of treatment for reuse of the purge water from the Refinery Duque de Caxias cooling towers by reverse osmosis (RO) was evaluated. The oil industry consumes huge volumes of water in the industrial refining operations and, due to the increasing demands and changes in the environmental legislation, reinforcing the reuse of it, the purge waters present high flows and chemical composition characteristics that make them proper for treatment for reuse. The RO process has two fundamental advantages for desmineralized water production in the industry: to decrease (or even to eliminate) the demand for chemical reagents used in the water treatment; and to reduce the effluent volumes. The characteristics of two commercial RO membranes (RO-1 polyamide and RO-2 cellulose acetate) were studied using a methodology established for this purpose, and the rejections for different chemical species were evaluated in the purge water from cooling towers. In general, rejections of chemical species higher than 90% were obtained with two RO membranes, and the characteristics of the water treated with them were comparable to those obtained with the conventional treatments. There was an increase in the water pH after the treatment using RO, so a final adjustment of the water pH is recommended before its use. The polyamide membrane presented better acting for the treatment of the purge water studied and the results point out the potential of employment of the RO membranes in the treatment of the cooling towers purge water from Refinery Duque de Caxias (Petrobras/Reduc).","Neste estudo avaliou-se a possibilidade do tratamento das águas de purga das torres de resfriamento por membranas de osmose inversa (OI) da Refinaria Duque de Caxias (Petrobras/Reduc) com finalidade de reuso. A indústria de petróleo consome apreciável quantidade de água nas operações industriais de refino e devido as crescentes exigências e mudanças na legislação ambiental pelo uso da mesma, as águas de purga por apresentarem apreciável vazão e características de composição químicas que as tornam passíveis de tratamento e reuso. O processo de OI possui duas vantagens fundamentais para produção de água desmineralizada em indústrias: reduzir (ou até eliminação) do consumo de reagentes químicos para tratamento de água; e reduzir os volumes de efluentes gerados. As características de duas membranas de OI comerciais (poliamida OI-1 e acetato de celulose OI-2) foram estudadas através de metodologia implementada com esta finalidade e as rejeições para diferentes espécies químicas foram avaliadas na água de purga das torres de resfriamento. De modo geral, rejeições de espécies químicas maiores que 90% foram obtidas com as duas membranas de OI, obtendo-se características comparáveis às da água tratada por métodos convencionais. Após tratamento por OI houve um aumento de pH da água sendo recomendado o ajuste final da mesma antes da sua utilização. A membrana de poliamida apresentou melhor desempenho para o tratamento desta água de purga e os resultados obtidos indicam o potencial de utilização de membranas de OI em tratamento de águas de purga das torres de resfriamento da Refinaria Duque de Caxias (Petrobras/Reduc)."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://app.uff.br/riuff/handle/1/20892"],"dc:language":["por"],"dc:publisher.department":["Química"],"dc:publisher.program":["Programa de Pós-graduação em Química"],"dc:rights":["Acesso Aberto"],"dc:rights.license":["CC-BY-SA"],"dc:subject":["Águas de purga","Torres de refrigeração","Indústria petrolífera","Água de reuso","Osmose inversa","Reuso da água","Dessalinização","Poluição ambiental","Waters of purge","Cooling towers","Petroliferous industry","Water of reuse"],"dc:subject.cnpq":["CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA"],"dc:title":["AVALIAÇÃO DE MEMBRANAS DE OSMOSE INVERSA NO TRATAMENTO DE ÁGUAS DE PURGA DE TORRES DE REFRIGERAÇÃO DE INDÚSTRIA PETROLÍFERA COM FINALIDADE DE REUSO"],"dc:title.alternative":["EVALUATION OF MEMBRANES OF INVERSE OSMOSIS IN THE WATER TREATMENT OF PURGES DE TOWERS OF REFRIGERATION OF PETROLIFEROUS INDUSTRY WITH PURPOSE OF REUSES"],"dc:type":["Dissertação"],"person:identifier.lattes":["http://lattes.cnpq.br/5543223323634478","http://lattes.cnpq.br/4914949489265543","http://lattes.cnpq.br/9226448743895474","http://lattes.cnpq.br/8965339627815488"]},"updated_at":"2026-11-26T20:40:29Z"}