{"id":{"repo_id":"brno-tech","oai_identifier":"oai:dspace.vut.cz:11012/208763"},"canonical_url":"https://search.ndltd.org/etd/brno-tech/oai:dspace.vut.cz:11012/208763","repository":{"repo_id":"brno-tech","name":"Brno University of Technology","base_url":"https://dspace.vut.cz/oai/request"},"display":{"title":"Modelování charakteristik proudění vzduchu a ukládání částic v horním dýchacím traktu člověka pomocí CFD simulací","abstract":"The objectives are to analyze the mechanisms of airflow and particle transport in the extrathoracic airways. Understanding these features in greater detail not only helps in the treatment of diseases related to the respiratory tract but also aims to reduce the amount of animal testing. For the evaluation, computational fluid dynamic (CFD) simulations were utilized. ANSYS was used as a leading software to perform a simulation of different inspiratory flow rates. In this work, Large Eddy Simulations (LES) is engaged due to its real-world performance. The geometry of the upper airways is obtained from CT scans, to preserve the topological data of the upper airways. Furthermore, the deposition of inhaled particles of varying diameters 1-10 m was examined, helping us better understand the therapeutic effects of inhaled particles. Two types of inhalations simulations were carried out. First, inhalation through the nose, simulating the inhalation with a nebulizer with airflow rates of 15 l/min and 30 l/min. Second, through mouth simulating inhalation with a dry-powder inhaler with a flow rate of 90 l/min. Simulated results show that most of the particles deposit at the entrance of the nasal or oral cavity. When flow rates of 15 and 30 l/min were compared, it can be seen the higher initial velocity is, the particles of large diameter (6-10 m) are stuck in the nasal cavity and do not appear in the laryngeal region, whereas with low velocity the more particles of 6-10 m can be found in this region. The maximum number of particles leaving the trachea was observed with a flow rate of 15 l/min, accounting for 26 %. As opposed to 90 l/min where only 13 % left the upper respiratory tract. Also, typical pressure drop can be observed in pressure contours describing the larynx region. This was most significant for a flow rate of 90 l/min where the pressure from the oropharynx to subglottis dropped by 490 Pa.","abstract_html":"The objectives are to analyze the mechanisms of airflow and particle transport in the extrathoracic airways. Understanding these features in greater detail not only helps in the treatment of diseases related to the respiratory tract but also aims to reduce the amount of animal testing. For the evaluation, computational fluid dynamic (CFD) simulations were utilized. ANSYS was used as a leading software to perform a simulation of different inspiratory flow rates. In this work, Large Eddy Simulations (LES) is engaged due to its real-world performance. The geometry of the upper airways is obtained from CT scans, to preserve the topological data of the upper airways. Furthermore, the deposition of inhaled particles of varying diameters 1-10 m was examined, helping us better understand the therapeutic effects of inhaled particles. Two types of inhalations simulations were carried out. First, inhalation through the nose, simulating the inhalation with a nebulizer with airflow rates of 15 l/min and 30 l/min. Second, through mouth simulating inhalation with a dry-powder inhaler with a flow rate of 90 l/min. Simulated results show that most of the particles deposit at the entrance of the nasal or oral cavity. When flow rates of 15 and 30 l/min were compared, it can be seen the higher initial velocity is, the particles of large diameter (6-10 m) are stuck in the nasal cavity and do not appear in the laryngeal region, whereas with low velocity the more particles of 6-10 m can be found in this region. The maximum number of particles leaving the trachea was observed with a flow rate of 15 l/min, accounting for 26 %. As opposed to 90 l/min where only 13 % left the upper respiratory tract. Also, typical pressure drop can be observed in pressure contours describing the larynx region. This was most significant for a flow rate of 90 l/min where the pressure from the oropharynx to subglottis dropped by 490 Pa.","abstract_has_math":false,"creators":["Pospíšil, Milan"],"institution":"Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií","degree_name":null,"degree_level":"Inženýrský","degree_discipline":"bez specializace","degree_department":null,"school":null,"contributors":[],"advisors":["Paštěka, Richard"],"committee_chairs":[],"committee_members":["Forjan, Mathias"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T03:09:56Z","subjects":["Upper Respiratory Tract (URT)","Particle Deposition","Aerosol Inhalation","Computational Fluid Dynamics (CFD) Simulation"],"languages":["en","angličtina (English)"],"rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["POSPÍŠIL, M. Modelování charakteristik proudění vzduchu a ukládání částic v horním dýchacím traktu člověka pomocí CFD simulací [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2022."],"render_values":[{"text":"POSPÍŠIL, M. Modelování charakteristik proudění vzduchu a ukládání částic v horním dýchacím traktu člověka pomocí CFD simulací [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2022.","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["137477"],"render_values":[{"text":"137477","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11012/208763","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11012/208763","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrno-tech%3Aoai%3Adspace.vut.cz%3A11012%2F208763","prefix":"oai_dc"},"source_record":{"url":"https://dspace.vut.cz/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.vut.cz%3A11012%2F208763","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Paštěka, Richard"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Forjan, Mathias"]},{"key":"dc:creator","label":"Author","values":["Pospíšil, Milan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.acceptance","label":"Dc Date Acceptance","values":["2022-11-09"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-01-24-11:17:14"]},{"key":"dc:publisher","label":"Institution","values":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:type","label":"Dc Type","values":["Text","masterThesis","diplomová práce"]},{"key":"thesis:defence_status","label":"Thesis Defence Status","values":["práce byla úspěšně obhájena"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["bez specializace"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Inženýrský"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Bioengineering"]},{"key":"thesis:examination_report","label":"Thesis Examination Report","values":["Student Milan Pospíšil úspěšně obhájil svou diplomovou práci a prokázal znalosti v oblasti teorie v rámci odborné rozpravy."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav biomedicínského inženýrství"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Upper Respiratory Tract (URT)","Particle Deposition","Aerosol Inhalation","Computational Fluid Dynamics (CFD) Simulation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["angličtina (English)"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Standardní licenční smlouva - přístup k plnému textu bez omezení"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["POSPÍŠIL, M. Modelování charakteristik proudění vzduchu a ukládání částic v horním dýchacím traktu člověka pomocí CFD simulací [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2022."]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["137477"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11012/208763"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objectives are to analyze the mechanisms of airflow and particle transport in the extrathoracic airways. Understanding these features in greater detail not only helps in the treatment of diseases related to the respiratory tract but also aims to reduce the amount of animal testing. For the evaluation, computational fluid dynamic (CFD) simulations were utilized. ANSYS was used as a leading software to perform a simulation of different inspiratory flow rates. In this work, Large Eddy Simulations (LES) is engaged due to its real-world performance. The geometry of the upper airways is obtained from CT scans, to preserve the topological data of the upper airways. Furthermore, the deposition of inhaled particles of varying diameters 1-10 m was examined, helping us better understand the therapeutic effects of inhaled particles. Two types of inhalations simulations were carried out. First, inhalation through the nose, simulating the inhalation with a nebulizer with airflow rates of 15 l/min and 30 l/min. Second, through mouth simulating inhalation with a dry-powder inhaler with a flow rate of 90 l/min. Simulated results show that most of the particles deposit at the entrance of the nasal or oral cavity. When flow rates of 15 and 30 l/min were compared, it can be seen the higher initial velocity is, the particles of large diameter (6-10 m) are stuck in the nasal cavity and do not appear in the laryngeal region, whereas with low velocity the more particles of 6-10 m can be found in this region. The maximum number of particles leaving the trachea was observed with a flow rate of 15 l/min, accounting for 26 %. As opposed to 90 l/min where only 13 % left the upper respiratory tract. Also, typical pressure drop can be observed in pressure contours describing the larynx region. This was most significant for a flow rate of 90 l/min where the pressure from the oropharynx to subglottis dropped by 490 Pa."]},{"key":"dc:description.grade","label":"Dc Description Grade","values":["A"]},{"key":"dc:title","label":"Title","values":["Modelování charakteristik proudění vzduchu a ukládání částic v horním dýchacím traktu člověka pomocí CFD simulací"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Modeling of Airflow Characteristics and Particle Deposition in Human Upper Respiratory Tract Using CFD Simulations"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]},{"key":"sync:item.dbid","label":"Sync Item Dbid","values":["137477"]},{"key":"sync:item.dbtype","label":"Sync Item Dbtype","values":["ZP"]},{"key":"sync:item.insts","label":"Sync Item Insts","values":["2026.05.18 22:02:12"]},{"key":"sync:item.modts","label":"Sync Item Modts","values":["2026.05.15 07:39:02"]}]}],"canonical_facts":{"dc:contributor.advisor":["Paštěka, Richard"],"dc:contributor.committeemember":["Forjan, Mathias"],"dc:creator":["Pospíšil, Milan"],"dc:date.acceptance":["2022-11-09"],"dc:date.created":["2022"],"dc:date.updated":["2023-01-24-11:17:14"],"dc:description.abstract":["The objectives are to analyze the mechanisms of airflow and particle transport in the extrathoracic airways. Understanding these features in greater detail not only helps in the treatment of diseases related to the respiratory tract but also aims to reduce the amount of animal testing. For the evaluation, computational fluid dynamic (CFD) simulations were utilized. ANSYS was used as a leading software to perform a simulation of different inspiratory flow rates. In this work, Large Eddy Simulations (LES) is engaged due to its real-world performance. The geometry of the upper airways is obtained from CT scans, to preserve the topological data of the upper airways. Furthermore, the deposition of inhaled particles of varying diameters 1-10 m was examined, helping us better understand the therapeutic effects of inhaled particles. Two types of inhalations simulations were carried out. First, inhalation through the nose, simulating the inhalation with a nebulizer with airflow rates of 15 l/min and 30 l/min. Second, through mouth simulating inhalation with a dry-powder inhaler with a flow rate of 90 l/min. Simulated results show that most of the particles deposit at the entrance of the nasal or oral cavity. When flow rates of 15 and 30 l/min were compared, it can be seen the higher initial velocity is, the particles of large diameter (6-10 m) are stuck in the nasal cavity and do not appear in the laryngeal region, whereas with low velocity the more particles of 6-10 m can be found in this region. The maximum number of particles leaving the trachea was observed with a flow rate of 15 l/min, accounting for 26 %. As opposed to 90 l/min where only 13 % left the upper respiratory tract. Also, typical pressure drop can be observed in pressure contours describing the larynx region. This was most significant for a flow rate of 90 l/min where the pressure from the oropharynx to subglottis dropped by 490 Pa."],"dc:description.grade":["A"],"dc:identifier.citation":["POSPÍŠIL, M. Modelování charakteristik proudění vzduchu a ukládání částic v horním dýchacím traktu člověka pomocí CFD simulací [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2022."],"dc:identifier.other":["137477"],"dc:identifier.uri":["http://hdl.handle.net/11012/208763"],"dc:language":["angličtina (English)"],"dc:language.iso":["en"],"dc:publisher":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"],"dc:publisher.faculty":["Fakulta elektrotechniky a komunikačních technologií"],"dc:rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"dc:subject":["Upper Respiratory Tract (URT)","Particle Deposition","Aerosol Inhalation","Computational Fluid Dynamics (CFD) Simulation"],"dc:title":["Modelování charakteristik proudění vzduchu a ukládání částic v horním dýchacím traktu člověka pomocí CFD simulací"],"dc:title.alternative":["Modeling of Airflow Characteristics and Particle Deposition in Human Upper Respiratory Tract Using CFD Simulations"],"dc:type":["Text","masterThesis","diplomová práce"],"others:access_status":["open.access"],"sync:item.dbid":["137477"],"sync:item.dbtype":["ZP"],"sync:item.insts":["2026.05.18 22:02:12"],"sync:item.modts":["2026.05.15 07:39:02"],"thesis:defence_status":["práce byla úspěšně obhájena"],"thesis:degree_discipline":["bez specializace"],"thesis:degree_level":["Inženýrský"],"thesis:degree_program":["Bioengineering"],"thesis:examination_report":["Student Milan Pospíšil úspěšně obhájil svou diplomovou práci a prokázal znalosti v oblasti teorie v rámci odborné rozpravy."],"thesis:institution_name":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav biomedicínského inženýrství"]},"updated_at":"2026-11-19T03:09:56Z"}