{"id":{"repo_id":"brno-tech","oai_identifier":"oai:dspace.vut.cz:11012/214431"},"canonical_url":"https://search.ndltd.org/etd/brno-tech/oai:dspace.vut.cz:11012/214431","repository":{"repo_id":"brno-tech","name":"Brno University of Technology","base_url":"https://dspace.vut.cz/oai/request"},"display":{"title":"Evaluation of selected thermophysiological model for the isolated, confined mission in Antarctica","abstract":"Over the past few decades, numerous models have been created to estimate human thermal responses. These models rely on energy balance equations that consider the heat exchange between the human body and its environment. These models have substantially progressed from one-node models into complex structures organized in multiple layers and connected by a circulatory blood flow. Although there is literature available comparing the possible utility of the thermophysiological models in different scenarios, little is known about the utility of these mod els in specific conditions. This work investigates and compares selected thermophysiological models, focusing on selecting a suitable model for the use case scenario of Antarctica. The data was collected during a longitudinal study located at Johann Gregor Mendel Czech Antarctic station. The local skin temperature of participants (n = 16) was measured 6 times over the period of the study. The first of each measurement set consisted of orthostatic tests in addition to psychomotor vigilance task and Iowa gambling test present which were present in each of the subsequent measurements. After examining specific experimental conditions, four thermophysiological models were com pared, and the JOS-3 model was determined to be the most appropriate for the thermal data obtained during the experiment. The results revealed that the selected JOS-3 model can accurately predict mean skin temper atures for both experiment designs (RMSD 0.72 and 0.75 C for experiment design 1 and 2 respectively). Furthermore, the JOS-3 model was able to reliably predict head (RMSD 0.82 and 1.13 C), neck (RMSD 0.61 and 1 C), and chest (RMSD 1.01 and 1.22 C) skin temperatures. However, deviations observed for back, hand, and foot segments were significant (RMSD 2.08 - 2.25 and 2.55 - 2.68 C). Possible explanations include uncertainty in clothing insulation of the worn clothing, uncertainty in measurement circumstances (contact with surfaces - floor, table), and the placement of the thermal sensors. The highest deviation was observed in the pelvis (RMSD 2.25 and 3.72 C) and is possibly a result of the JOS-3 model overestimation of heat production in the segment. The study has underscored the significance of obtaining compre hensive data on clothing type and sensor placement for enhancing the accuracy of simulation outcomes.","abstract_html":"Over the past few decades, numerous models have been created to estimate human thermal responses. These models rely on energy balance equations that consider the heat exchange between the human body and its environment. These models have substantially progressed from one-node models into complex structures organized in multiple layers and connected by a circulatory blood flow. Although there is literature available comparing the possible utility of the thermophysiological models in different scenarios, little is known about the utility of these mod els in specific conditions. This work investigates and compares selected thermophysiological models, focusing on selecting a suitable model for the use case scenario of Antarctica. The data was collected during a longitudinal study located at Johann Gregor Mendel Czech Antarctic station. The local skin temperature of participants (n = 16) was measured 6 times over the period of the study. The first of each measurement set consisted of orthostatic tests in addition to psychomotor vigilance task and Iowa gambling test present which were present in each of the subsequent measurements. After examining specific experimental conditions, four thermophysiological models were com pared, and the JOS-3 model was determined to be the most appropriate for the thermal data obtained during the experiment. The results revealed that the selected JOS-3 model can accurately predict mean skin temper atures for both experiment designs (RMSD 0.72 and 0.75 C for experiment design 1 and 2 respectively). Furthermore, the JOS-3 model was able to reliably predict head (RMSD 0.82 and 1.13 C), neck (RMSD 0.61 and 1 C), and chest (RMSD 1.01 and 1.22 C) skin temperatures. However, deviations observed for back, hand, and foot segments were significant (RMSD 2.08 - 2.25 and 2.55 - 2.68 C). Possible explanations include uncertainty in clothing insulation of the worn clothing, uncertainty in measurement circumstances (contact with surfaces - floor, table), and the placement of the thermal sensors. The highest deviation was observed in the pelvis (RMSD 2.25 and 3.72 C) and is possibly a result of the JOS-3 model overestimation of heat production in the segment. The study has underscored the significance of obtaining compre hensive data on clothing type and sensor placement for enhancing the accuracy of simulation outcomes.","abstract_has_math":false,"creators":["Bečička, Martin"],"institution":"Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií","degree_name":null,"degree_level":"Inženýrský","degree_discipline":"bez specializace","degree_department":null,"school":null,"contributors":[],"advisors":["Paštěka, Richard"],"committee_chairs":[],"committee_members":["Dobrovolná,, Julie"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T01:38:03Z","subjects":["thermophysiological model","thermal comfort","local skin temperature"],"languages":["cs","čeština (Czech)"],"rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["BEČIČKA, M. Evaluation of selected thermophysiological model for the isolated, confined mission in Antarctica [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2023."],"render_values":[{"text":"BEČIČKA, M. Evaluation of selected thermophysiological model for the isolated, confined mission in Antarctica [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2023.","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["145054"],"render_values":[{"text":"145054","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11012/214431","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11012/214431","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrno-tech%3Aoai%3Adspace.vut.cz%3A11012%2F214431","prefix":"oai_dc"},"source_record":{"url":"https://dspace.vut.cz/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.vut.cz%3A11012%2F214431","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Paštěka, Richard"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Dobrovolná,, Julie"]},{"key":"dc:creator","label":"Author","values":["Bečička, Martin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.acceptance","label":"Dc Date Acceptance","values":["2023-06-27"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-05-17-12:52:01"]},{"key":"dc:publisher","label":"Institution","values":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:type","label":"Dc Type","values":["Text","masterThesis","diplomová práce"]},{"key":"thesis:defence_status","label":"Thesis Defence Status","values":["práce byla úspěšně obhájena"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["bez specializace"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Inženýrský"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Bioengineering (Double Degree)"]},{"key":"thesis:examination_report","label":"Thesis Examination Report","values":["Student prezentoval svou práci a odpověděl na dotazy. Student obhájil svou diplomovou práci."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav biomedicínského inženýrství"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["thermophysiological model","thermal comfort","local skin temperature"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["čeština (Czech)"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["cs"]},{"key":"dc:rights","label":"Dc Rights","values":["Standardní licenční smlouva - přístup k plnému textu bez omezení"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["BEČIČKA, M. Evaluation of selected thermophysiological model for the isolated, confined mission in Antarctica [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2023."]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["145054"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11012/214431"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Over the past few decades, numerous models have been created to estimate human thermal responses. These models rely on energy balance equations that consider the heat exchange between the human body and its environment. These models have substantially progressed from one-node models into complex structures organized in multiple layers and connected by a circulatory blood flow. Although there is literature available comparing the possible utility of the thermophysiological models in different scenarios, little is known about the utility of these mod els in specific conditions. This work investigates and compares selected thermophysiological models, focusing on selecting a suitable model for the use case scenario of Antarctica. The data was collected during a longitudinal study located at Johann Gregor Mendel Czech Antarctic station. The local skin temperature of participants (n = 16) was measured 6 times over the period of the study. The first of each measurement set consisted of orthostatic tests in addition to psychomotor vigilance task and Iowa gambling test present which were present in each of the subsequent measurements. After examining specific experimental conditions, four thermophysiological models were com pared, and the JOS-3 model was determined to be the most appropriate for the thermal data obtained during the experiment. The results revealed that the selected JOS-3 model can accurately predict mean skin temper atures for both experiment designs (RMSD 0.72 and 0.75 C for experiment design 1 and 2 respectively). Furthermore, the JOS-3 model was able to reliably predict head (RMSD 0.82 and 1.13 C), neck (RMSD 0.61 and 1 C), and chest (RMSD 1.01 and 1.22 C) skin temperatures. However, deviations observed for back, hand, and foot segments were significant (RMSD 2.08 - 2.25 and 2.55 - 2.68 C). Possible explanations include uncertainty in clothing insulation of the worn clothing, uncertainty in measurement circumstances (contact with surfaces - floor, table), and the placement of the thermal sensors. The highest deviation was observed in the pelvis (RMSD 2.25 and 3.72 C) and is possibly a result of the JOS-3 model overestimation of heat production in the segment. The study has underscored the significance of obtaining compre hensive data on clothing type and sensor placement for enhancing the accuracy of simulation outcomes."]},{"key":"dc:description.grade","label":"Dc Description Grade","values":["B"]},{"key":"dc:title","label":"Title","values":["Evaluation of selected thermophysiological model for the isolated, confined mission in Antarctica"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Evaluation of selected thermophysiological model for the isolated, confined mission in Antarctica"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]},{"key":"sync:item.dbid","label":"Sync Item Dbid","values":["145054"]},{"key":"sync:item.dbtype","label":"Sync Item Dbtype","values":["ZP"]},{"key":"sync:item.insts","label":"Sync Item Insts","values":["2026.05.18 22:03:18"]},{"key":"sync:item.modts","label":"Sync Item Modts","values":["2026.05.14 23:57:09"]}]}],"canonical_facts":{"dc:contributor.advisor":["Paštěka, Richard"],"dc:contributor.committeemember":["Dobrovolná,, Julie"],"dc:creator":["Bečička, Martin"],"dc:date.acceptance":["2023-06-27"],"dc:date.created":["2023"],"dc:date.updated":["2024-05-17-12:52:01"],"dc:description.abstract":["Over the past few decades, numerous models have been created to estimate human thermal responses. These models rely on energy balance equations that consider the heat exchange between the human body and its environment. These models have substantially progressed from one-node models into complex structures organized in multiple layers and connected by a circulatory blood flow. Although there is literature available comparing the possible utility of the thermophysiological models in different scenarios, little is known about the utility of these mod els in specific conditions. This work investigates and compares selected thermophysiological models, focusing on selecting a suitable model for the use case scenario of Antarctica. The data was collected during a longitudinal study located at Johann Gregor Mendel Czech Antarctic station. The local skin temperature of participants (n = 16) was measured 6 times over the period of the study. The first of each measurement set consisted of orthostatic tests in addition to psychomotor vigilance task and Iowa gambling test present which were present in each of the subsequent measurements. After examining specific experimental conditions, four thermophysiological models were com pared, and the JOS-3 model was determined to be the most appropriate for the thermal data obtained during the experiment. The results revealed that the selected JOS-3 model can accurately predict mean skin temper atures for both experiment designs (RMSD 0.72 and 0.75 C for experiment design 1 and 2 respectively). Furthermore, the JOS-3 model was able to reliably predict head (RMSD 0.82 and 1.13 C), neck (RMSD 0.61 and 1 C), and chest (RMSD 1.01 and 1.22 C) skin temperatures. However, deviations observed for back, hand, and foot segments were significant (RMSD 2.08 - 2.25 and 2.55 - 2.68 C). Possible explanations include uncertainty in clothing insulation of the worn clothing, uncertainty in measurement circumstances (contact with surfaces - floor, table), and the placement of the thermal sensors. The highest deviation was observed in the pelvis (RMSD 2.25 and 3.72 C) and is possibly a result of the JOS-3 model overestimation of heat production in the segment. The study has underscored the significance of obtaining compre hensive data on clothing type and sensor placement for enhancing the accuracy of simulation outcomes."],"dc:description.grade":["B"],"dc:identifier.citation":["BEČIČKA, M. Evaluation of selected thermophysiological model for the isolated, confined mission in Antarctica [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2023."],"dc:identifier.other":["145054"],"dc:identifier.uri":["http://hdl.handle.net/11012/214431"],"dc:language":["čeština (Czech)"],"dc:language.iso":["cs"],"dc:publisher":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"],"dc:publisher.faculty":["Fakulta elektrotechniky a komunikačních technologií"],"dc:rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"dc:subject":["thermophysiological model","thermal comfort","local skin temperature"],"dc:title":["Evaluation of selected thermophysiological model for the isolated, confined mission in Antarctica"],"dc:title.alternative":["Evaluation of selected thermophysiological model for the isolated, confined mission in Antarctica"],"dc:type":["Text","masterThesis","diplomová práce"],"others:access_status":["open.access"],"sync:item.dbid":["145054"],"sync:item.dbtype":["ZP"],"sync:item.insts":["2026.05.18 22:03:18"],"sync:item.modts":["2026.05.14 23:57:09"],"thesis:defence_status":["práce byla úspěšně obhájena"],"thesis:degree_discipline":["bez specializace"],"thesis:degree_level":["Inženýrský"],"thesis:degree_program":["Bioengineering (Double Degree)"],"thesis:examination_report":["Student prezentoval svou práci a odpověděl na dotazy. Student obhájil svou diplomovou práci."],"thesis:institution_name":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav biomedicínského inženýrství"]},"updated_at":"2026-11-19T01:38:03Z"}