{"id":{"repo_id":"brno-tech","oai_identifier":"oai:dspace.vut.cz:11012/253431"},"canonical_url":"https://search.ndltd.org/etd/brno-tech/oai:dspace.vut.cz:11012/253431","repository":{"repo_id":"brno-tech","name":"Brno University of Technology","base_url":"https://dspace.vut.cz/oai/request"},"display":{"title":"Hodnocení vlivu prostředí magnetické rezonance na akvizici a analýzu simultánního HD-EEG signálu","abstract":"Simultaneous recording of high-density electroencephalography (HD-EEG) and functional magnetic resonance imaging (fMRI), known as EEG-fMRI, allows the investigation of the relationship between brain activity and blood flow. However, the strong electromagnetic fields in the magnetic resonance (MR) environment pose significant challenges for EEG signal quality, including artifacts such as gradient switching, pulse-related, and motion-induced disturbances. This thesis aims to explore the impact of the MR environment on HD-EEG signal acquisition by comparing data recorded in a shielded cabin versus inside the MR scanner. A preprocessing pipeline is applied to both datasets to reduce noise and artifacts, using methods such as the independent component analysis (ICA). Moreover, a microstate analysis was then performed to identify stable topographic patterns in the EEG data, as well as to extract relevant spatiotemporal parameters for each recording setting and both combined. Statistical comparisons revealed significant differences in global explained variance (GEV), mean duration, and occurrence between the two environments. Despite some spatial similarities in dominant microstates, temporal dynamics were notably influenced by the measurement surrounding. Potential sources include remaining artifacts, postural differences between recording setups, and environmental factors such as MR scanner noise. These findings emphasize the importance of considering acquisition conditions when interpreting EEG microstate data.","abstract_html":"Simultaneous recording of high-density electroencephalography (HD-EEG) and functional magnetic resonance imaging (fMRI), known as EEG-fMRI, allows the investigation of the relationship between brain activity and blood flow. However, the strong electromagnetic fields in the magnetic resonance (MR) environment pose significant challenges for EEG signal quality, including artifacts such as gradient switching, pulse-related, and motion-induced disturbances. This thesis aims to explore the impact of the MR environment on HD-EEG signal acquisition by comparing data recorded in a shielded cabin versus inside the MR scanner. A preprocessing pipeline is applied to both datasets to reduce noise and artifacts, using methods such as the independent component analysis (ICA). Moreover, a microstate analysis was then performed to identify stable topographic patterns in the EEG data, as well as to extract relevant spatiotemporal parameters for each recording setting and both combined. Statistical comparisons revealed significant differences in global explained variance (GEV), mean duration, and occurrence between the two environments. Despite some spatial similarities in dominant microstates, temporal dynamics were notably influenced by the measurement surrounding. Potential sources include remaining artifacts, postural differences between recording setups, and environmental factors such as MR scanner noise. These findings emphasize the importance of considering acquisition conditions when interpreting EEG microstate data.","abstract_has_math":false,"creators":["Hauenschild, Ramona"],"institution":"Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií","degree_name":null,"degree_level":"Inženýrský","degree_discipline":"bez specializace","degree_department":null,"school":null,"contributors":[],"advisors":["Jordánek, Tomáš"],"committee_chairs":[],"committee_members":["Lamoš, Martin","doc. Ing. Jiří Hozman, Ph.D. (předseda) Ing. Andrea Němcová, Ph.D. (místopředseda) Ing. Oto Janoušek, Ph.D. (člen) Ing. Vojtěch Bartoň (člen) Ing. Martin Lamoš, Ph.D. (člen) MUDr. Michal Jurajda, Ph.D. (člen)"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T01:52:50Z","subjects":["high-density EEG","fMRI","simultaneous EEG-fMRI","shielded cabin","EEG microstates","EEG preprocessing","microstate analysis"],"languages":["en","angličtina (English)"],"rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["HAUENSCHILD, R. Hodnocení vlivu prostředí magnetické rezonance na akvizici a analýzu simultánního HD-EEG signálu [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2025."],"render_values":[{"text":"HAUENSCHILD, R. Hodnocení vlivu prostředí magnetické rezonance na akvizici a analýzu simultánního HD-EEG signálu [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2025.","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["167547"],"render_values":[{"text":"167547","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11012/253431","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11012/253431","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrno-tech%3Aoai%3Adspace.vut.cz%3A11012%2F253431","prefix":"oai_dc"},"source_record":{"url":"https://dspace.vut.cz/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.vut.cz%3A11012%2F253431","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jordánek, Tomáš"]},{"key":"dc:contributor.committee","label":"Committee Member","values":["doc. Ing. Jiří Hozman, Ph.D. (předseda) Ing. Andrea Němcová, Ph.D. (místopředseda) Ing. Oto Janoušek, Ph.D. (člen) Ing. Vojtěch Bartoň (člen) Ing. Martin Lamoš, Ph.D. (člen) MUDr. Michal Jurajda, Ph.D. (člen)"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Lamoš, Martin"]},{"key":"dc:creator","label":"Author","values":["Hauenschild, Ramona"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.acceptance","label":"Dc Date Acceptance","values":["2025-06-17"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-06-26-10:36:26"]},{"key":"dc:publisher","label":"Institution","values":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:type","label":"Dc Type","values":["Text","masterThesis","diplomová práce"]},{"key":"thesis:defence_status","label":"Thesis Defence Status","values":["práce byla úspěšně obhájena"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["bez specializace"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Inženýrský"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Bioengineering (Double Degree)"]},{"key":"thesis:examination_report","label":"Thesis Examination Report","values":["Student presented the results of his master thesis and the committee members were acquainted with the reviews. Ing. Janoušek asked: How did you determine the number of selected components? Did you try to use scree plot for that? Doc. Hozman asked: How will your results be used in the future? Student defended the master thesis and answered the questions."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav biomedicínského inženýrství"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["high-density EEG","fMRI","simultaneous EEG-fMRI","shielded cabin","EEG microstates","EEG preprocessing","microstate analysis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["angličtina (English)"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Standardní licenční smlouva - přístup k plnému textu bez omezení"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["HAUENSCHILD, R. Hodnocení vlivu prostředí magnetické rezonance na akvizici a analýzu simultánního HD-EEG signálu [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2025."]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["167547"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11012/253431"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Simultaneous recording of high-density electroencephalography (HD-EEG) and functional magnetic resonance imaging (fMRI), known as EEG-fMRI, allows the investigation of the relationship between brain activity and blood flow. However, the strong electromagnetic fields in the magnetic resonance (MR) environment pose significant challenges for EEG signal quality, including artifacts such as gradient switching, pulse-related, and motion-induced disturbances. This thesis aims to explore the impact of the MR environment on HD-EEG signal acquisition by comparing data recorded in a shielded cabin versus inside the MR scanner. A preprocessing pipeline is applied to both datasets to reduce noise and artifacts, using methods such as the independent component analysis (ICA). Moreover, a microstate analysis was then performed to identify stable topographic patterns in the EEG data, as well as to extract relevant spatiotemporal parameters for each recording setting and both combined. Statistical comparisons revealed significant differences in global explained variance (GEV), mean duration, and occurrence between the two environments. Despite some spatial similarities in dominant microstates, temporal dynamics were notably influenced by the measurement surrounding. Potential sources include remaining artifacts, postural differences between recording setups, and environmental factors such as MR scanner noise. These findings emphasize the importance of considering acquisition conditions when interpreting EEG microstate data."]},{"key":"dc:description.grade","label":"Dc Description Grade","values":["A"]},{"key":"dc:title","label":"Title","values":["Hodnocení vlivu prostředí magnetické rezonance na akvizici a analýzu simultánního HD-EEG signálu"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["The effect of the magnetic resonance environment on the acquisition and analysis of the simultaneous HD-EEG signal"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]},{"key":"sync:item.dbid","label":"Sync Item Dbid","values":["167547"]},{"key":"sync:item.dbtype","label":"Sync Item Dbtype","values":["ZP"]},{"key":"sync:item.insts","label":"Sync Item Insts","values":["2026.05.18 23:00:46"]},{"key":"sync:item.modts","label":"Sync Item Modts","values":["2026.05.15 12:35:44"]}]}],"canonical_facts":{"dc:contributor.advisor":["Jordánek, Tomáš"],"dc:contributor.committee":["doc. Ing. Jiří Hozman, Ph.D. (předseda) Ing. Andrea Němcová, Ph.D. (místopředseda) Ing. Oto Janoušek, Ph.D. (člen) Ing. Vojtěch Bartoň (člen) Ing. Martin Lamoš, Ph.D. (člen) MUDr. Michal Jurajda, Ph.D. (člen)"],"dc:contributor.committeemember":["Lamoš, Martin"],"dc:creator":["Hauenschild, Ramona"],"dc:date.acceptance":["2025-06-17"],"dc:date.created":["2025"],"dc:date.updated":["2025-06-26-10:36:26"],"dc:description.abstract":["Simultaneous recording of high-density electroencephalography (HD-EEG) and functional magnetic resonance imaging (fMRI), known as EEG-fMRI, allows the investigation of the relationship between brain activity and blood flow. However, the strong electromagnetic fields in the magnetic resonance (MR) environment pose significant challenges for EEG signal quality, including artifacts such as gradient switching, pulse-related, and motion-induced disturbances. This thesis aims to explore the impact of the MR environment on HD-EEG signal acquisition by comparing data recorded in a shielded cabin versus inside the MR scanner. A preprocessing pipeline is applied to both datasets to reduce noise and artifacts, using methods such as the independent component analysis (ICA). Moreover, a microstate analysis was then performed to identify stable topographic patterns in the EEG data, as well as to extract relevant spatiotemporal parameters for each recording setting and both combined. Statistical comparisons revealed significant differences in global explained variance (GEV), mean duration, and occurrence between the two environments. Despite some spatial similarities in dominant microstates, temporal dynamics were notably influenced by the measurement surrounding. Potential sources include remaining artifacts, postural differences between recording setups, and environmental factors such as MR scanner noise. These findings emphasize the importance of considering acquisition conditions when interpreting EEG microstate data."],"dc:description.grade":["A"],"dc:identifier.citation":["HAUENSCHILD, R. Hodnocení vlivu prostředí magnetické rezonance na akvizici a analýzu simultánního HD-EEG signálu [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2025."],"dc:identifier.other":["167547"],"dc:identifier.uri":["http://hdl.handle.net/11012/253431"],"dc:language":["angličtina (English)"],"dc:language.iso":["en"],"dc:publisher":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"],"dc:publisher.faculty":["Fakulta elektrotechniky a komunikačních technologií"],"dc:rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"dc:subject":["high-density EEG","fMRI","simultaneous EEG-fMRI","shielded cabin","EEG microstates","EEG preprocessing","microstate analysis"],"dc:title":["Hodnocení vlivu prostředí magnetické rezonance na akvizici a analýzu simultánního HD-EEG signálu"],"dc:title.alternative":["The effect of the magnetic resonance environment on the acquisition and analysis of the simultaneous HD-EEG signal"],"dc:type":["Text","masterThesis","diplomová práce"],"others:access_status":["open.access"],"sync:item.dbid":["167547"],"sync:item.dbtype":["ZP"],"sync:item.insts":["2026.05.18 23:00:46"],"sync:item.modts":["2026.05.15 12:35:44"],"thesis:defence_status":["práce byla úspěšně obhájena"],"thesis:degree_discipline":["bez specializace"],"thesis:degree_level":["Inženýrský"],"thesis:degree_program":["Bioengineering (Double Degree)"],"thesis:examination_report":["Student presented the results of his master thesis and the committee members were acquainted with the reviews. Ing. Janoušek asked: How did you determine the number of selected components? Did you try to use scree plot for that? Doc. Hozman asked: How will your results be used in the future? Student defended the master thesis and answered the questions."],"thesis:institution_name":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav biomedicínského inženýrství"]},"updated_at":"2026-11-19T01:52:50Z"}