{"id":{"repo_id":"brno-tech","oai_identifier":"oai:dspace.vut.cz:11012/255820"},"canonical_url":"https://search.ndltd.org/etd/brno-tech/oai:dspace.vut.cz:11012/255820","repository":{"repo_id":"brno-tech","name":"Brno University of Technology","base_url":"https://dspace.vut.cz/oai/request"},"display":{"title":"POC-System for on-chip electrochemical detection of pathogens for treatment of periodontitis","abstract":"Periodontitis is a widespread inflammatory disease of the oral cavity that demands rapid and accurate diagnostic methods to improve clinical outcomes. Point-of-care (POC) biosensors offer a promising approach for the timely detection of periodontal pathogens directly in dental practices. This study presents the characterization of newly developed microfluidic FoldChips employing enzyme-based DNA detection using two analytical techniques: electrochemical (EC) and chemiluminescence (CL) based detection. Measurement protocols, signal analysis methods, and calibration models were established for both detection methods. The FoldChip system was evaluated using DNA standards specific to Aggregatibacter actinomycetemcomitans, Prevotella intermedia (Pi), Porphyromonas gingivalis (Pg), Treponema denticola (Td), Tannerella forsythia (Tf), and total germ load (TGL), as well as with viable cells of Escherichia coli (E. coli) and Pi. Both EC and CL modes achieved dynamic ranges of 0.01–25 nM and limits of detection (LOD) below 1.2 nM. However, CL provided higher consistency and sensitivity for DNA standards, with LODs of 12–55 pM (excluding Pi), while EC demonstrated a broader LOD range of 23 pM–1.2 nM, with the best-performing probes yielding LODs of 23 pM (Pg), 26 pM (Tf), and 31 pM (TGL). In cell-based assays, EC detection showed approximately tenfold greater sensitivity compared to CL, achieving LODs of 2.2 · 103 cells/L (TGL, E. coli) and 5.6 · 105 cells/L (Pi), versus 9.71 · 104 cells/L and 1.96 · 106 cells/L for CL, respectively. These results demonstrate the FoldChip as a versatile and sensitive platform for periodontal pathogen detection, compatible with both EC and CL readouts. Its multiplexing capability and potential for integration into compact POC systems highlight its promise for future clinical diagnostics in periodontology.","abstract_html":"Periodontitis is a widespread inflammatory disease of the oral cavity that demands rapid and accurate diagnostic methods to improve clinical outcomes. Point-of-care (POC) biosensors offer a promising approach for the timely detection of periodontal pathogens directly in dental practices. This study presents the characterization of newly developed microfluidic FoldChips employing enzyme-based DNA detection using two analytical techniques: electrochemical (EC) and chemiluminescence (CL) based detection. Measurement protocols, signal analysis methods, and calibration models were established for both detection methods. The FoldChip system was evaluated using DNA standards specific to Aggregatibacter actinomycetemcomitans, Prevotella intermedia (Pi), Porphyromonas gingivalis (Pg), Treponema denticola (Td), Tannerella forsythia (Tf), and total germ load (TGL), as well as with viable cells of Escherichia coli (E. coli) and Pi. Both EC and CL modes achieved dynamic ranges of 0.01–25 nM and limits of detection (LOD) below 1.2 nM. However, CL provided higher consistency and sensitivity for DNA standards, with LODs of 12–55 pM (excluding Pi), while EC demonstrated a broader LOD range of 23 pM–1.2 nM, with the best-performing probes yielding LODs of 23 pM (Pg), 26 pM (Tf), and 31 pM (TGL). In cell-based assays, EC detection showed approximately tenfold greater sensitivity compared to CL, achieving LODs of 2.2 · 103 cells/L (TGL, E. coli) and 5.6 · 105 cells/L (Pi), versus 9.71 · 104 cells/L and 1.96 · 106 cells/L for CL, respectively. These results demonstrate the FoldChip as a versatile and sensitive platform for periodontal pathogen detection, compatible with both EC and CL readouts. Its multiplexing capability and potential for integration into compact POC systems highlight its promise for future clinical diagnostics in periodontology.","abstract_has_math":false,"creators":["Chválová, Zuzana Lujza"],"institution":"Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií","degree_name":null,"degree_level":"Inženýrský","degree_discipline":"bez specializace","degree_department":null,"school":null,"contributors":[],"advisors":["Weiland, Kathrin"],"committee_chairs":[],"committee_members":["Melnik, Eva"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T01:54:07Z","subjects":["Microfluidic biosensor","Electrochemical detection","Chemiluminescence","Periodontal pathogens","Point-of-care diagnostics"],"languages":["en","angličtina (English)"],"rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["CHVÁLOVÁ, Z. POC-System for on-chip electrochemical detection of pathogens for treatment of periodontitis [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2025."],"render_values":[{"text":"CHVÁLOVÁ, Z. POC-System for on-chip electrochemical detection of pathogens for treatment of periodontitis [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2025.","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["163246"],"render_values":[{"text":"163246","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11012/255820","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11012/255820","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrno-tech%3Aoai%3Adspace.vut.cz%3A11012%2F255820","prefix":"oai_dc"},"source_record":{"url":"https://dspace.vut.cz/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.vut.cz%3A11012%2F255820","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Weiland, Kathrin"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Melnik, Eva"]},{"key":"dc:creator","label":"Author","values":["Chválová, Zuzana Lujza"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.acceptance","label":"Dc Date Acceptance","values":["2025-11-04"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-01-19-09:33:36"]},{"key":"dc:publisher","label":"Institution","values":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:type","label":"Dc Type","values":["Text","masterThesis","diplomová práce"]},{"key":"thesis:defence_status","label":"Thesis Defence Status","values":["práce byla úspěšně obhájena"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["bez specializace"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Inženýrský"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Bioengineering (Double Degree)"]},{"key":"thesis:examination_report","label":"Thesis Examination Report","values":["Master's thesis graded ‘Excellent’. The candidate is able to apply knowledge from various fields of study in a technically correct manner to new situations, going far beyond the essentials and doing so with confidence and at a very high level of argumentation."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav biomedicínského inženýrství"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microfluidic biosensor","Electrochemical detection","Chemiluminescence","Periodontal pathogens","Point-of-care diagnostics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["angličtina (English)"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Standardní licenční smlouva - přístup k plnému textu bez omezení"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["CHVÁLOVÁ, Z. POC-System for on-chip electrochemical detection of pathogens for treatment of periodontitis [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2025."]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["163246"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11012/255820"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Periodontitis is a widespread inflammatory disease of the oral cavity that demands rapid and accurate diagnostic methods to improve clinical outcomes. Point-of-care (POC) biosensors offer a promising approach for the timely detection of periodontal pathogens directly in dental practices. This study presents the characterization of newly developed microfluidic FoldChips employing enzyme-based DNA detection using two analytical techniques: electrochemical (EC) and chemiluminescence (CL) based detection. Measurement protocols, signal analysis methods, and calibration models were established for both detection methods. The FoldChip system was evaluated using DNA standards specific to Aggregatibacter actinomycetemcomitans, Prevotella intermedia (Pi), Porphyromonas gingivalis (Pg), Treponema denticola (Td), Tannerella forsythia (Tf), and total germ load (TGL), as well as with viable cells of Escherichia coli (E. coli) and Pi. Both EC and CL modes achieved dynamic ranges of 0.01–25 nM and limits of detection (LOD) below 1.2 nM. However, CL provided higher consistency and sensitivity for DNA standards, with LODs of 12–55 pM (excluding Pi), while EC demonstrated a broader LOD range of 23 pM–1.2 nM, with the best-performing probes yielding LODs of 23 pM (Pg), 26 pM (Tf), and 31 pM (TGL). In cell-based assays, EC detection showed approximately tenfold greater sensitivity compared to CL, achieving LODs of 2.2 · 103 cells/L (TGL, E. coli) and 5.6 · 105 cells/L (Pi), versus 9.71 · 104 cells/L and 1.96 · 106 cells/L for CL, respectively. These results demonstrate the FoldChip as a versatile and sensitive platform for periodontal pathogen detection, compatible with both EC and CL readouts. Its multiplexing capability and potential for integration into compact POC systems highlight its promise for future clinical diagnostics in periodontology."]},{"key":"dc:description.grade","label":"Dc Description Grade","values":["A"]},{"key":"dc:title","label":"Title","values":["POC-System for on-chip electrochemical detection of pathogens for treatment of periodontitis"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["POC-System for on-chip electrochemical detection of pathogens for treatment of periodontitis"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]},{"key":"sync:item.dbid","label":"Sync Item Dbid","values":["163246"]},{"key":"sync:item.dbtype","label":"Sync Item Dbtype","values":["ZP"]},{"key":"sync:item.insts","label":"Sync Item Insts","values":["2026.05.18 23:00:54"]},{"key":"sync:item.modts","label":"Sync Item Modts","values":["2026.05.15 05:31:36"]}]}],"canonical_facts":{"dc:contributor.advisor":["Weiland, Kathrin"],"dc:contributor.committeemember":["Melnik, Eva"],"dc:creator":["Chválová, Zuzana Lujza"],"dc:date.acceptance":["2025-11-04"],"dc:date.created":["2025"],"dc:date.updated":["2026-01-19-09:33:36"],"dc:description.abstract":["Periodontitis is a widespread inflammatory disease of the oral cavity that demands rapid and accurate diagnostic methods to improve clinical outcomes. Point-of-care (POC) biosensors offer a promising approach for the timely detection of periodontal pathogens directly in dental practices. This study presents the characterization of newly developed microfluidic FoldChips employing enzyme-based DNA detection using two analytical techniques: electrochemical (EC) and chemiluminescence (CL) based detection. Measurement protocols, signal analysis methods, and calibration models were established for both detection methods. The FoldChip system was evaluated using DNA standards specific to Aggregatibacter actinomycetemcomitans, Prevotella intermedia (Pi), Porphyromonas gingivalis (Pg), Treponema denticola (Td), Tannerella forsythia (Tf), and total germ load (TGL), as well as with viable cells of Escherichia coli (E. coli) and Pi. Both EC and CL modes achieved dynamic ranges of 0.01–25 nM and limits of detection (LOD) below 1.2 nM. However, CL provided higher consistency and sensitivity for DNA standards, with LODs of 12–55 pM (excluding Pi), while EC demonstrated a broader LOD range of 23 pM–1.2 nM, with the best-performing probes yielding LODs of 23 pM (Pg), 26 pM (Tf), and 31 pM (TGL). In cell-based assays, EC detection showed approximately tenfold greater sensitivity compared to CL, achieving LODs of 2.2 · 103 cells/L (TGL, E. coli) and 5.6 · 105 cells/L (Pi), versus 9.71 · 104 cells/L and 1.96 · 106 cells/L for CL, respectively. These results demonstrate the FoldChip as a versatile and sensitive platform for periodontal pathogen detection, compatible with both EC and CL readouts. Its multiplexing capability and potential for integration into compact POC systems highlight its promise for future clinical diagnostics in periodontology."],"dc:description.grade":["A"],"dc:identifier.citation":["CHVÁLOVÁ, Z. POC-System for on-chip electrochemical detection of pathogens for treatment of periodontitis [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2025."],"dc:identifier.other":["163246"],"dc:identifier.uri":["http://hdl.handle.net/11012/255820"],"dc:language":["angličtina (English)"],"dc:language.iso":["en"],"dc:publisher":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"],"dc:publisher.faculty":["Fakulta elektrotechniky a komunikačních technologií"],"dc:rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"dc:subject":["Microfluidic biosensor","Electrochemical detection","Chemiluminescence","Periodontal pathogens","Point-of-care diagnostics"],"dc:title":["POC-System for on-chip electrochemical detection of pathogens for treatment of periodontitis"],"dc:title.alternative":["POC-System for on-chip electrochemical detection of pathogens for treatment of periodontitis"],"dc:type":["Text","masterThesis","diplomová práce"],"others:access_status":["open.access"],"sync:item.dbid":["163246"],"sync:item.dbtype":["ZP"],"sync:item.insts":["2026.05.18 23:00:54"],"sync:item.modts":["2026.05.15 05:31:36"],"thesis:defence_status":["práce byla úspěšně obhájena"],"thesis:degree_discipline":["bez specializace"],"thesis:degree_level":["Inženýrský"],"thesis:degree_program":["Bioengineering (Double Degree)"],"thesis:examination_report":["Master's thesis graded ‘Excellent’. The candidate is able to apply knowledge from various fields of study in a technically correct manner to new situations, going far beyond the essentials and doing so with confidence and at a very high level of argumentation."],"thesis:institution_name":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav biomedicínského inženýrství"]},"updated_at":"2026-11-19T01:54:07Z"}