{"id":{"repo_id":"brno-tech","oai_identifier":"oai:dspace.vut.cz:11012/256722"},"canonical_url":"https://search.ndltd.org/etd/brno-tech/oai:dspace.vut.cz:11012/256722","repository":{"repo_id":"brno-tech","name":"Brno University of Technology","base_url":"https://dspace.vut.cz/oai/request"},"display":{"title":"Treatment of Ammonia-Containing Industrial Wastewater Using Air Stripping: Insights from a Pilot-Scale Study","abstract":"This pilot-scale study evaluates the technical performance and economic viability of an integrated ammonia stripping and condensation process for treatment and resource recovery from industrial nickel-plating wastewater within the HydroNet project. The objective was to achieve effluent ammonium concentrations below 1,000 mg/L suitable for municipal discharge while recovering a 10–25 wt% ammonium hydroxide product for the hydrogen market. Although targets were not fully reached (1,700 mg/L and 8.08 wt%), the results indicate that both are technically achievable under optimized operating conditions, particularly through improved stripping and condensation performance and extended treatment duration. The process proved economically profitable under pilot-scale conditions, in particular under the HydroNet funding scheme. Despite a limited dataset (N=10), the study provides valuable pilot-scale insight, bridging laboratory research and industrial implementation. It highlights the strong coupling between stripping performance and condensation efficiency, and demonstrates the need for real-world pilot-scale data for reliable process scale-up.","abstract_html":"This pilot-scale study evaluates the technical performance and economic viability of an integrated ammonia stripping and condensation process for treatment and resource recovery from industrial nickel-plating wastewater within the HydroNet project. The objective was to achieve effluent ammonium concentrations below 1,000 mg/L suitable for municipal discharge while recovering a 10–25 wt% ammonium hydroxide product for the hydrogen market. Although targets were not fully reached (1,700 mg/L and 8.08 wt%), the results indicate that both are technically achievable under optimized operating conditions, particularly through improved stripping and condensation performance and extended treatment duration. The process proved economically profitable under pilot-scale conditions, in particular under the HydroNet funding scheme. Despite a limited dataset (N=10), the study provides valuable pilot-scale insight, bridging laboratory research and industrial implementation. It highlights the strong coupling between stripping performance and condensation efficiency, and demonstrates the need for real-world pilot-scale data for reliable process scale-up.","abstract_has_math":false,"creators":["O’Shea, Rachel"],"institution":"Vysoké učení technické v Brně. Fakulta chemická","degree_name":null,"degree_level":"Inženýrský","degree_discipline":"bez specializace","degree_department":null,"school":null,"contributors":[],"advisors":["Repková, Martina"],"committee_chairs":[],"committee_members":["Holba, Marek","doc. Mgr. Renata Komendová, Ph.D. (člen) doc. MVDr. Helena Zlámalová Gargošová, Ph.D. (člen) Ing. Jiří Másilko, Ph.D. (člen) doc. Ing. Pavel Krystyník, Ph.D. (člen) doc. Ing. Tomáš Rozsypal, Ph.D. (člen) prof. Ing. Jozef Krajčovič, Ph.D. (předseda) doc. Mgr. Michaela Vašinová Galiová, Ph.D. (místopředseda)"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T01:54:35Z","subjects":["Air Stripping","Ammonia-Rich Wastewater","Ammonium Hydroxide","Circular Economy","Condensation Performance","Downstream Treatment","HydroNet","Industrial Wastewater Treatment","Nickel-Plating Wastewater","Pilot-Scale Study","Process Optimization","Recovery","Removal","Stripping Performance","ZEA"],"languages":["en","angličtina (English)"],"rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["O’SHEA, R. Treatment of Ammonia-Containing Industrial Wastewater Using Air Stripping: Insights from a Pilot-Scale Study [online]. Brno: Vysoké učení technické v Brně. Fakulta chemická. 2026."],"render_values":[{"text":"O’SHEA, R. Treatment of Ammonia-Containing Industrial Wastewater Using Air Stripping: Insights from a Pilot-Scale Study [online]. Brno: Vysoké učení technické v Brně. Fakulta chemická. 2026.","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["170751"],"render_values":[{"text":"170751","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11012/256722","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11012/256722","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrno-tech%3Aoai%3Adspace.vut.cz%3A11012%2F256722","prefix":"oai_dc"},"source_record":{"url":"https://dspace.vut.cz/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.vut.cz%3A11012%2F256722","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Repková, Martina"]},{"key":"dc:contributor.committee","label":"Committee Member","values":["doc. Mgr. Renata Komendová, Ph.D. (člen) doc. MVDr. Helena Zlámalová Gargošová, Ph.D. (člen) Ing. Jiří Másilko, Ph.D. (člen) doc. Ing. Pavel Krystyník, Ph.D. (člen) doc. Ing. Tomáš Rozsypal, Ph.D. (člen) prof. Ing. Jozef Krajčovič, Ph.D. (předseda) doc. Mgr. Michaela Vašinová Galiová, Ph.D. (místopředseda)"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Holba, Marek"]},{"key":"dc:creator","label":"Author","values":["O’Shea, Rachel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.acceptance","label":"Dc Date Acceptance","values":["2026-05-29"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-06-05-07:20:06"]},{"key":"dc:publisher","label":"Institution","values":["Vysoké učení technické v Brně. Fakulta chemická"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Fakulta chemická"]},{"key":"dc:type","label":"Dc Type","values":["Text","masterThesis","diplomová práce"]},{"key":"thesis:defence_status","label":"Thesis Defence Status","values":["práce byla úspěšně obhájena"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["bez specializace"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Inženýrský"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Environmental Sciences and Engineering"]},{"key":"thesis:examination_report","label":"Thesis Examination Report","values":["The student presented her thesis, its content and results. Afterwards, the supervisor’s and opponent’s opinions were read and questions were answered. Other members of the committee joined the discussion with the following questions. Prof. J. Krajčovič Assoc. Prof. M. Vašinová Galiová – What was the ICP-OES used for? Assoc. Prof. R. Komendová Assoc. Prof. H. Zlámalová Gargošová Dr. J. Másilko – Witch temperature was used for the stripping in your work? What was the capacity? Assoc. Prof. P. Krystyník – Do you know a process that would be applicable to the concentration levels used in your work? Assoc. Prof. T. Rozsypal The student addressed all supplementary questions posed by the members of the Commission during the discussion. She demonstrated an excellent understanding of the topic and a strong orientation within the subject matter. Following the discussion, the thesis was evaluated. The student proved not only outstanding professional knowledge but also the capability to independently present and defend her results."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Ing.","Vysoké učení technické v Brně. Fakulta chemická. Ústav chemie a technologie ochrany životního prostředí"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Air Stripping","Ammonia-Rich Wastewater","Ammonium Hydroxide","Circular Economy","Condensation Performance","Downstream Treatment","HydroNet","Industrial Wastewater Treatment","Nickel-Plating Wastewater","Pilot-Scale Study","Process Optimization","Recovery","Removal","Stripping Performance","ZEA"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["angličtina (English)"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Standardní licenční smlouva - přístup k plnému textu bez omezení"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["O’SHEA, R. Treatment of Ammonia-Containing Industrial Wastewater Using Air Stripping: Insights from a Pilot-Scale Study [online]. Brno: Vysoké učení technické v Brně. Fakulta chemická. 2026."]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["170751"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11012/256722"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This pilot-scale study evaluates the technical performance and economic viability of an integrated ammonia stripping and condensation process for treatment and resource recovery from industrial nickel-plating wastewater within the HydroNet project. The objective was to achieve effluent ammonium concentrations below 1,000 mg/L suitable for municipal discharge while recovering a 10–25 wt% ammonium hydroxide product for the hydrogen market. Although targets were not fully reached (1,700 mg/L and 8.08 wt%), the results indicate that both are technically achievable under optimized operating conditions, particularly through improved stripping and condensation performance and extended treatment duration. The process proved economically profitable under pilot-scale conditions, in particular under the HydroNet funding scheme. Despite a limited dataset (N=10), the study provides valuable pilot-scale insight, bridging laboratory research and industrial implementation. It highlights the strong coupling between stripping performance and condensation efficiency, and demonstrates the need for real-world pilot-scale data for reliable process scale-up."]},{"key":"dc:description.grade","label":"Dc Description Grade","values":["A"]},{"key":"dc:title","label":"Title","values":["Treatment of Ammonia-Containing Industrial Wastewater Using Air Stripping: Insights from a Pilot-Scale Study"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Treatment of Ammonia-Containing Industrial Wastewater Using Air Stripping: Insights from a Pilot-Scale Study"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]},{"key":"sync:item.dbid","label":"Sync Item Dbid","values":["170751"]},{"key":"sync:item.dbtype","label":"Sync Item Dbtype","values":["ZP"]},{"key":"sync:item.insts","label":"Sync Item Insts","values":["2026.07.07 19:02:36"]},{"key":"sync:item.modts","label":"Sync Item Modts","values":["2026.07.07 12:57:44"]}]}],"canonical_facts":{"dc:contributor.advisor":["Repková, Martina"],"dc:contributor.committee":["doc. Mgr. Renata Komendová, Ph.D. (člen) doc. MVDr. Helena Zlámalová Gargošová, Ph.D. (člen) Ing. Jiří Másilko, Ph.D. (člen) doc. Ing. Pavel Krystyník, Ph.D. (člen) doc. Ing. Tomáš Rozsypal, Ph.D. (člen) prof. Ing. Jozef Krajčovič, Ph.D. (předseda) doc. Mgr. Michaela Vašinová Galiová, Ph.D. (místopředseda)"],"dc:contributor.committeemember":["Holba, Marek"],"dc:creator":["O’Shea, Rachel"],"dc:date.acceptance":["2026-05-29"],"dc:date.created":["2026"],"dc:date.updated":["2026-06-05-07:20:06"],"dc:description.abstract":["This pilot-scale study evaluates the technical performance and economic viability of an integrated ammonia stripping and condensation process for treatment and resource recovery from industrial nickel-plating wastewater within the HydroNet project. The objective was to achieve effluent ammonium concentrations below 1,000 mg/L suitable for municipal discharge while recovering a 10–25 wt% ammonium hydroxide product for the hydrogen market. Although targets were not fully reached (1,700 mg/L and 8.08 wt%), the results indicate that both are technically achievable under optimized operating conditions, particularly through improved stripping and condensation performance and extended treatment duration. The process proved economically profitable under pilot-scale conditions, in particular under the HydroNet funding scheme. Despite a limited dataset (N=10), the study provides valuable pilot-scale insight, bridging laboratory research and industrial implementation. It highlights the strong coupling between stripping performance and condensation efficiency, and demonstrates the need for real-world pilot-scale data for reliable process scale-up."],"dc:description.grade":["A"],"dc:identifier.citation":["O’SHEA, R. Treatment of Ammonia-Containing Industrial Wastewater Using Air Stripping: Insights from a Pilot-Scale Study [online]. Brno: Vysoké učení technické v Brně. Fakulta chemická. 2026."],"dc:identifier.other":["170751"],"dc:identifier.uri":["http://hdl.handle.net/11012/256722"],"dc:language":["angličtina (English)"],"dc:language.iso":["en"],"dc:publisher":["Vysoké učení technické v Brně. Fakulta chemická"],"dc:publisher.faculty":["Fakulta chemická"],"dc:rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"dc:subject":["Air Stripping","Ammonia-Rich Wastewater","Ammonium Hydroxide","Circular Economy","Condensation Performance","Downstream Treatment","HydroNet","Industrial Wastewater Treatment","Nickel-Plating Wastewater","Pilot-Scale Study","Process Optimization","Recovery","Removal","Stripping Performance","ZEA"],"dc:title":["Treatment of Ammonia-Containing Industrial Wastewater Using Air Stripping: Insights from a Pilot-Scale Study"],"dc:title.alternative":["Treatment of Ammonia-Containing Industrial Wastewater Using Air Stripping: Insights from a Pilot-Scale Study"],"dc:type":["Text","masterThesis","diplomová práce"],"others:access_status":["open.access"],"sync:item.dbid":["170751"],"sync:item.dbtype":["ZP"],"sync:item.insts":["2026.07.07 19:02:36"],"sync:item.modts":["2026.07.07 12:57:44"],"thesis:defence_status":["práce byla úspěšně obhájena"],"thesis:degree_discipline":["bez specializace"],"thesis:degree_level":["Inženýrský"],"thesis:degree_program":["Environmental Sciences and Engineering"],"thesis:examination_report":["The student presented her thesis, its content and results. Afterwards, the supervisor’s and opponent’s opinions were read and questions were answered. Other members of the committee joined the discussion with the following questions. Prof. J. Krajčovič Assoc. Prof. M. Vašinová Galiová – What was the ICP-OES used for? Assoc. Prof. R. Komendová Assoc. Prof. H. Zlámalová Gargošová Dr. J. Másilko – Witch temperature was used for the stripping in your work? What was the capacity? Assoc. Prof. P. Krystyník – Do you know a process that would be applicable to the concentration levels used in your work? Assoc. Prof. T. Rozsypal The student addressed all supplementary questions posed by the members of the Commission during the discussion. She demonstrated an excellent understanding of the topic and a strong orientation within the subject matter. Following the discussion, the thesis was evaluated. The student proved not only outstanding professional knowledge but also the capability to independently present and defend her results."],"thesis:institution_name":["Ing.","Vysoké učení technické v Brně. Fakulta chemická. Ústav chemie a technologie ochrany životního prostředí"]},"updated_at":"2026-11-19T01:54:35Z"}