{"id":{"repo_id":"brno-tech","oai_identifier":"oai:dspace.vut.cz:11012/257294"},"canonical_url":"https://search.ndltd.org/etd/brno-tech/oai:dspace.vut.cz:11012/257294","repository":{"repo_id":"brno-tech","name":"Brno University of Technology","base_url":"https://dspace.vut.cz/oai/request"},"display":{"title":"Anomaly detection in air quality using olfactory sensors and machine learning methods","abstract":"This work presents a machine-learning approach to indoor air-quality monitoring using Bosch Sensortec BME688 multi-sensor arrays. Measurements follow a fixed ten-step heater profile; after warm-up removal and windowing, each steady-state segment is summarized into up to 800 statistical features, with per-substance baseline normalization and scaling fit on normal training air only. Principal component analysis (typically 70 components) reduces dimensionality before modeling. Three binary detectors are compared under one protocol: a supervised Random Forest, a dense autoencoder, and an LSTM autoencoder trained on normal air. Data comprise clean air and five volatiles (Acetone, Redidlo, Savo, Softasept, and Vinegar), with day based data training and testing. Thresholds are chosen on validation data separately from training. The Random Forest achieves the strongest ranking and detection performance; autoencoders reach ROC-AUC 0.95 with a sharper threshold trade-off. Multiclass results are strong for Acetone and Softasept but weak for Redidlo and Savo. The study supports automated vapor screening in controlled settings and shows that binary anomaly detection is more reliable than full substance labeling for the hardest materials.","abstract_html":"This work presents a machine-learning approach to indoor air-quality monitoring using Bosch Sensortec BME688 multi-sensor arrays. Measurements follow a fixed ten-step heater profile; after warm-up removal and windowing, each steady-state segment is summarized into up to 800 statistical features, with per-substance baseline normalization and scaling fit on normal training air only. Principal component analysis (typically 70 components) reduces dimensionality before modeling. Three binary detectors are compared under one protocol: a supervised Random Forest, a dense autoencoder, and an LSTM autoencoder trained on normal air. Data comprise clean air and five volatiles (Acetone, Redidlo, Savo, Softasept, and Vinegar), with day based data training and testing. Thresholds are chosen on validation data separately from training. The Random Forest achieves the strongest ranking and detection performance; autoencoders reach ROC-AUC 0.95 with a sharper threshold trade-off. Multiclass results are strong for Acetone and Softasept but weak for Redidlo and Savo. The study supports automated vapor screening in controlled settings and shows that binary anomaly detection is more reliable than full substance labeling for the hardest materials.","abstract_has_math":false,"creators":["Agafari, Yonatan Tekle"],"institution":"Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií","degree_name":null,"degree_level":"Inženýrský","degree_discipline":"bez specializace","degree_department":null,"school":null,"contributors":[],"advisors":["Kříž, Petr"],"committee_chairs":[],"committee_members":["Sikora, Pavel","prof. Ing. Zdeněk Smékal, CSc. (předseda) doc. Ing. Ivo Lattenberg, Ph.D. (místopředseda) doc. Ing. Lukáš Malina, Ph.D. (člen) Ing. Štěpán Miklánek, Ph.D. (člen) Ing. Jiří Přinosil, Ph.D. (člen) Ing. Adrián Tomašov, Ph.D. (člen) Ing. et Ing. Petr Musil (člen) Ing. Filip Wagner (člen)"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T04:13:36Z","subjects":["Anomaly detection","gas sensors","BME688","indoor air quality","volatile organic compounds","principal component analysis","random forest","autoencoder","LSTM","threshold calibration"],"languages":["en","angličtina (English)"],"rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["AGAFARI, Y. Anomaly detection in air quality using olfactory sensors and machine learning methods [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2026."],"render_values":[{"text":"AGAFARI, Y. Anomaly detection in air quality using olfactory sensors and machine learning methods [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2026.","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["175370"],"render_values":[{"text":"175370","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11012/257294","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11012/257294","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrno-tech%3Aoai%3Adspace.vut.cz%3A11012%2F257294","prefix":"oai_dc"},"source_record":{"url":"https://dspace.vut.cz/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.vut.cz%3A11012%2F257294","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kříž, Petr"]},{"key":"dc:contributor.committee","label":"Committee Member","values":["prof. Ing. Zdeněk Smékal, CSc. (předseda) doc. Ing. Ivo Lattenberg, Ph.D. (místopředseda) doc. Ing. Lukáš Malina, Ph.D. (člen) Ing. Štěpán Miklánek, Ph.D. (člen) Ing. Jiří Přinosil, Ph.D. (člen) Ing. Adrián Tomašov, Ph.D. (člen) Ing. et Ing. Petr Musil (člen) Ing. Filip Wagner (člen)"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sikora, Pavel"]},{"key":"dc:creator","label":"Author","values":["Agafari, Yonatan Tekle"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.acceptance","label":"Dc Date Acceptance","values":["2026-06-09"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-06-11-11:14:48"]},{"key":"dc:publisher","label":"Institution","values":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:type","label":"Dc Type","values":["Text","masterThesis","diplomová práce"]},{"key":"thesis:defence_status","label":"Thesis Defence Status","values":["práce byla úspěšně obhájena"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["bez specializace"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Inženýrský"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Communications and Networking (Double-Degree)"]},{"key":"thesis:examination_report","label":"Thesis Examination Report","values":["Student presented the results of his thesis and the committee got familiar with reviewer's report. Student defended his Diploma Thesis. and answered the questions from the members of the committee and the reviewer"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav telekomunikací"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Anomaly detection","gas sensors","BME688","indoor air quality","volatile organic compounds","principal component analysis","random forest","autoencoder","LSTM","threshold calibration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["angličtina (English)"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Standardní licenční smlouva - přístup k plnému textu bez omezení"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["AGAFARI, Y. Anomaly detection in air quality using olfactory sensors and machine learning methods [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2026."]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["175370"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11012/257294"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This work presents a machine-learning approach to indoor air-quality monitoring using Bosch Sensortec BME688 multi-sensor arrays. Measurements follow a fixed ten-step heater profile; after warm-up removal and windowing, each steady-state segment is summarized into up to 800 statistical features, with per-substance baseline normalization and scaling fit on normal training air only. Principal component analysis (typically 70 components) reduces dimensionality before modeling. Three binary detectors are compared under one protocol: a supervised Random Forest, a dense autoencoder, and an LSTM autoencoder trained on normal air. Data comprise clean air and five volatiles (Acetone, Redidlo, Savo, Softasept, and Vinegar), with day based data training and testing. Thresholds are chosen on validation data separately from training. The Random Forest achieves the strongest ranking and detection performance; autoencoders reach ROC-AUC 0.95 with a sharper threshold trade-off. Multiclass results are strong for Acetone and Softasept but weak for Redidlo and Savo. The study supports automated vapor screening in controlled settings and shows that binary anomaly detection is more reliable than full substance labeling for the hardest materials."]},{"key":"dc:description.grade","label":"Dc Description Grade","values":["B"]},{"key":"dc:title","label":"Title","values":["Anomaly detection in air quality using olfactory sensors and machine learning methods"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Anomaly detection in air quality using olfactory sensors and machine learning methods"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]},{"key":"sync:item.dbid","label":"Sync Item Dbid","values":["175370"]},{"key":"sync:item.dbtype","label":"Sync Item Dbtype","values":["ZP"]},{"key":"sync:item.insts","label":"Sync Item Insts","values":["2026.07.07 19:03:10"]},{"key":"sync:item.modts","label":"Sync Item Modts","values":["2026.07.07 12:41:20"]}]}],"canonical_facts":{"dc:contributor.advisor":["Kříž, Petr"],"dc:contributor.committee":["prof. Ing. Zdeněk Smékal, CSc. (předseda) doc. Ing. Ivo Lattenberg, Ph.D. (místopředseda) doc. Ing. Lukáš Malina, Ph.D. (člen) Ing. Štěpán Miklánek, Ph.D. (člen) Ing. Jiří Přinosil, Ph.D. (člen) Ing. Adrián Tomašov, Ph.D. (člen) Ing. et Ing. Petr Musil (člen) Ing. Filip Wagner (člen)"],"dc:contributor.committeemember":["Sikora, Pavel"],"dc:creator":["Agafari, Yonatan Tekle"],"dc:date.acceptance":["2026-06-09"],"dc:date.created":["2026"],"dc:date.updated":["2026-06-11-11:14:48"],"dc:description.abstract":["This work presents a machine-learning approach to indoor air-quality monitoring using Bosch Sensortec BME688 multi-sensor arrays. Measurements follow a fixed ten-step heater profile; after warm-up removal and windowing, each steady-state segment is summarized into up to 800 statistical features, with per-substance baseline normalization and scaling fit on normal training air only. Principal component analysis (typically 70 components) reduces dimensionality before modeling. Three binary detectors are compared under one protocol: a supervised Random Forest, a dense autoencoder, and an LSTM autoencoder trained on normal air. Data comprise clean air and five volatiles (Acetone, Redidlo, Savo, Softasept, and Vinegar), with day based data training and testing. Thresholds are chosen on validation data separately from training. The Random Forest achieves the strongest ranking and detection performance; autoencoders reach ROC-AUC 0.95 with a sharper threshold trade-off. Multiclass results are strong for Acetone and Softasept but weak for Redidlo and Savo. The study supports automated vapor screening in controlled settings and shows that binary anomaly detection is more reliable than full substance labeling for the hardest materials."],"dc:description.grade":["B"],"dc:identifier.citation":["AGAFARI, Y. Anomaly detection in air quality using olfactory sensors and machine learning methods [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2026."],"dc:identifier.other":["175370"],"dc:identifier.uri":["http://hdl.handle.net/11012/257294"],"dc:language":["angličtina (English)"],"dc:language.iso":["en"],"dc:publisher":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"],"dc:publisher.faculty":["Fakulta elektrotechniky a komunikačních technologií"],"dc:rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"dc:subject":["Anomaly detection","gas sensors","BME688","indoor air quality","volatile organic compounds","principal component analysis","random forest","autoencoder","LSTM","threshold calibration"],"dc:title":["Anomaly detection in air quality using olfactory sensors and machine learning methods"],"dc:title.alternative":["Anomaly detection in air quality using olfactory sensors and machine learning methods"],"dc:type":["Text","masterThesis","diplomová práce"],"others:access_status":["open.access"],"sync:item.dbid":["175370"],"sync:item.dbtype":["ZP"],"sync:item.insts":["2026.07.07 19:03:10"],"sync:item.modts":["2026.07.07 12:41:20"],"thesis:defence_status":["práce byla úspěšně obhájena"],"thesis:degree_discipline":["bez specializace"],"thesis:degree_level":["Inženýrský"],"thesis:degree_program":["Communications and Networking (Double-Degree)"],"thesis:examination_report":["Student presented the results of his thesis and the committee got familiar with reviewer's report. Student defended his Diploma Thesis. and answered the questions from the members of the committee and the reviewer"],"thesis:institution_name":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav telekomunikací"]},"updated_at":"2026-11-19T04:13:36Z"}