{"id":{"repo_id":"brno-tech","oai_identifier":"oai:dspace.vut.cz:11012/257332"},"canonical_url":"https://search.ndltd.org/etd/brno-tech/oai:dspace.vut.cz:11012/257332","repository":{"repo_id":"brno-tech","name":"Brno University of Technology","base_url":"https://dspace.vut.cz/oai/request"},"display":{"title":"Radar-Based Vital Signs Sensing in Vehicles","abstract":"This diploma thesis investigates the feasibility of measuring human vital signs in a vehicle interior using a 60 GHz FMCW MIMO radar. The theoretical part describes the operating principles of FMCW radars, range and phase measurement, angular processing with antenna arrays, and the limits imposed by chirp design. It also summarizes relevant literature on radar-based vital-sign sensing, with emphasis on in-vehicle use, where body motion, vehicle vibrations, clutter, multipath propagation, and the overlap between breathing and heart-rate harmonics make the task difficult. The practical part describes the construction of a radar measurement system based on the TI AWR6843ISK and DCA1000EVM boards, including radar attachment, reference sensor selection, radar data processing, target tracking, and exploratory visualization tools. Several methods for vital-sign extraction were tested, including STFT analysis, band-pass filtering with Hilbert-transform-based instantaneous frequency estimation, correlation-based approaches, and a sliding-window FFT method. Heart-rate extraction proved unreliable in the measured data, mainly because the HR signal was weak and often overlapped with breathing harmonics. The work therefore focuses on breathing-rate-related features as a more robust indicator of human presence. The final evaluation compares human target tracks with strong inanimate reference tracks in several parked and driving scenarios. The results show that breathing-related amplitude, detrended phase, and non-zero Doppler-bin power can provide useful separation between humans and inanimate objects, with average SNR values generally above 20 dB. The work does not yet provide a finished production-ready vital-sign monitor, but it establishes a working radar processing chain, identifies the main practical limitations, and gives a basis for future development of in-vehicle radar-based occupancy and passenger-state monitoring.","abstract_html":"This diploma thesis investigates the feasibility of measuring human vital signs in a vehicle interior using a 60 GHz FMCW MIMO radar. The theoretical part describes the operating principles of FMCW radars, range and phase measurement, angular processing with antenna arrays, and the limits imposed by chirp design. It also summarizes relevant literature on radar-based vital-sign sensing, with emphasis on in-vehicle use, where body motion, vehicle vibrations, clutter, multipath propagation, and the overlap between breathing and heart-rate harmonics make the task difficult. The practical part describes the construction of a radar measurement system based on the TI AWR6843ISK and DCA1000EVM boards, including radar attachment, reference sensor selection, radar data processing, target tracking, and exploratory visualization tools. Several methods for vital-sign extraction were tested, including STFT analysis, band-pass filtering with Hilbert-transform-based instantaneous frequency estimation, correlation-based approaches, and a sliding-window FFT method. Heart-rate extraction proved unreliable in the measured data, mainly because the HR signal was weak and often overlapped with breathing harmonics. The work therefore focuses on breathing-rate-related features as a more robust indicator of human presence. The final evaluation compares human target tracks with strong inanimate reference tracks in several parked and driving scenarios. The results show that breathing-related amplitude, detrended phase, and non-zero Doppler-bin power can provide useful separation between humans and inanimate objects, with average SNR values generally above 20 dB. The work does not yet provide a finished production-ready vital-sign monitor, but it establishes a working radar processing chain, identifies the main practical limitations, and gives a basis for future development of in-vehicle radar-based occupancy and passenger-state monitoring.","abstract_has_math":false,"creators":["Svoboda, Martin"],"institution":"Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií","degree_name":null,"degree_level":"Inženýrský","degree_discipline":"bez specializace","degree_department":null,"school":null,"contributors":[],"advisors":["Valach, Soběslav"],"committee_chairs":[],"committee_members":["Kaczmarczyk, Václav","prof. Ing. Michal Prauzek, Ph.D. (předseda) doc. Ing. Petr Beneš, Ph.D. (místopředseda) doc. Ing. Jakub Arm, Ph.D. (člen) Ing. Martin Čala, Ph.D. (člen) Ing. Jaroslav Lepka, Ph.D. (člen) prof. Ing. Radomil Matoušek, Ph.D. (člen) Ing. Lukáš Pohl, Ph.D. (člen)"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T04:12:05Z","subjects":["FMCW radar","MIMO System","vital signs monitoring"],"languages":["en","angličtina (English)"],"rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["SVOBODA, M. Radar-Based Vital Signs Sensing in Vehicles [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2026."],"render_values":[{"text":"SVOBODA, M. Radar-Based Vital Signs Sensing in Vehicles [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2026.","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["176070"],"render_values":[{"text":"176070","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11012/257332","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11012/257332","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrno-tech%3Aoai%3Adspace.vut.cz%3A11012%2F257332","prefix":"oai_dc"},"source_record":{"url":"https://dspace.vut.cz/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.vut.cz%3A11012%2F257332","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Valach, Soběslav"]},{"key":"dc:contributor.committee","label":"Committee Member","values":["prof. Ing. Michal Prauzek, Ph.D. (předseda) doc. Ing. Petr Beneš, Ph.D. (místopředseda) doc. Ing. Jakub Arm, Ph.D. (člen) Ing. Martin Čala, Ph.D. (člen) Ing. Jaroslav Lepka, Ph.D. (člen) prof. Ing. Radomil Matoušek, Ph.D. (člen) Ing. Lukáš Pohl, Ph.D. (člen)"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kaczmarczyk, Václav"]},{"key":"dc:creator","label":"Author","values":["Svoboda, Martin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.acceptance","label":"Dc Date Acceptance","values":["2026-06-09"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-06-11-11:22:27"]},{"key":"dc:publisher","label":"Institution","values":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Fakulta elektrotechniky a komunikačních technologií"]},{"key":"dc:type","label":"Dc Type","values":["Text","masterThesis","diplomová práce"]},{"key":"thesis:defence_status","label":"Thesis Defence Status","values":["práce byla úspěšně obhájena"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["bez specializace"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Inženýrský"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Kybernetika, automatizace a měření"]},{"key":"thesis:examination_report","label":"Thesis Examination Report","values":["Student odprezentoval svou práci a zodpověděl otázky oponenta. Proběhla diskuse ohledně zohlednění variability srdečního cyklu při analýze a ohledně použitých metod detekce. Student komisí vyzdvižené nedostatky práce u obhajoby nezastíral, stejně jako v práci. Komise se ptala na porovnání s referenčním sensorem, které však provedeno v práci s relevantním snímačem nebylo."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav automatizace a měřicí techniky"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["FMCW radar","MIMO System","vital signs monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["angličtina (English)"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Standardní licenční smlouva - přístup k plnému textu bez omezení"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["SVOBODA, M. Radar-Based Vital Signs Sensing in Vehicles [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2026."]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["176070"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11012/257332"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This diploma thesis investigates the feasibility of measuring human vital signs in a vehicle interior using a 60 GHz FMCW MIMO radar. The theoretical part describes the operating principles of FMCW radars, range and phase measurement, angular processing with antenna arrays, and the limits imposed by chirp design. It also summarizes relevant literature on radar-based vital-sign sensing, with emphasis on in-vehicle use, where body motion, vehicle vibrations, clutter, multipath propagation, and the overlap between breathing and heart-rate harmonics make the task difficult. The practical part describes the construction of a radar measurement system based on the TI AWR6843ISK and DCA1000EVM boards, including radar attachment, reference sensor selection, radar data processing, target tracking, and exploratory visualization tools. Several methods for vital-sign extraction were tested, including STFT analysis, band-pass filtering with Hilbert-transform-based instantaneous frequency estimation, correlation-based approaches, and a sliding-window FFT method. Heart-rate extraction proved unreliable in the measured data, mainly because the HR signal was weak and often overlapped with breathing harmonics. The work therefore focuses on breathing-rate-related features as a more robust indicator of human presence. The final evaluation compares human target tracks with strong inanimate reference tracks in several parked and driving scenarios. The results show that breathing-related amplitude, detrended phase, and non-zero Doppler-bin power can provide useful separation between humans and inanimate objects, with average SNR values generally above 20 dB. The work does not yet provide a finished production-ready vital-sign monitor, but it establishes a working radar processing chain, identifies the main practical limitations, and gives a basis for future development of in-vehicle radar-based occupancy and passenger-state monitoring."]},{"key":"dc:description.grade","label":"Dc Description Grade","values":["C"]},{"key":"dc:title","label":"Title","values":["Radar-Based Vital Signs Sensing in Vehicles"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Radar-Based Vital Signs Sensing in Vehicles"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]},{"key":"sync:item.dbid","label":"Sync Item Dbid","values":["176070"]},{"key":"sync:item.dbtype","label":"Sync Item Dbtype","values":["ZP"]},{"key":"sync:item.insts","label":"Sync Item Insts","values":["2026.07.07 19:03:24"]},{"key":"sync:item.modts","label":"Sync Item Modts","values":["2026.07.07 13:18:23"]}]}],"canonical_facts":{"dc:contributor.advisor":["Valach, Soběslav"],"dc:contributor.committee":["prof. Ing. Michal Prauzek, Ph.D. (předseda) doc. Ing. Petr Beneš, Ph.D. (místopředseda) doc. Ing. Jakub Arm, Ph.D. (člen) Ing. Martin Čala, Ph.D. (člen) Ing. Jaroslav Lepka, Ph.D. (člen) prof. Ing. Radomil Matoušek, Ph.D. (člen) Ing. Lukáš Pohl, Ph.D. (člen)"],"dc:contributor.committeemember":["Kaczmarczyk, Václav"],"dc:creator":["Svoboda, Martin"],"dc:date.acceptance":["2026-06-09"],"dc:date.created":["2026"],"dc:date.updated":["2026-06-11-11:22:27"],"dc:description.abstract":["This diploma thesis investigates the feasibility of measuring human vital signs in a vehicle interior using a 60 GHz FMCW MIMO radar. The theoretical part describes the operating principles of FMCW radars, range and phase measurement, angular processing with antenna arrays, and the limits imposed by chirp design. It also summarizes relevant literature on radar-based vital-sign sensing, with emphasis on in-vehicle use, where body motion, vehicle vibrations, clutter, multipath propagation, and the overlap between breathing and heart-rate harmonics make the task difficult. The practical part describes the construction of a radar measurement system based on the TI AWR6843ISK and DCA1000EVM boards, including radar attachment, reference sensor selection, radar data processing, target tracking, and exploratory visualization tools. Several methods for vital-sign extraction were tested, including STFT analysis, band-pass filtering with Hilbert-transform-based instantaneous frequency estimation, correlation-based approaches, and a sliding-window FFT method. Heart-rate extraction proved unreliable in the measured data, mainly because the HR signal was weak and often overlapped with breathing harmonics. The work therefore focuses on breathing-rate-related features as a more robust indicator of human presence. The final evaluation compares human target tracks with strong inanimate reference tracks in several parked and driving scenarios. The results show that breathing-related amplitude, detrended phase, and non-zero Doppler-bin power can provide useful separation between humans and inanimate objects, with average SNR values generally above 20 dB. The work does not yet provide a finished production-ready vital-sign monitor, but it establishes a working radar processing chain, identifies the main practical limitations, and gives a basis for future development of in-vehicle radar-based occupancy and passenger-state monitoring."],"dc:description.grade":["C"],"dc:identifier.citation":["SVOBODA, M. Radar-Based Vital Signs Sensing in Vehicles [online]. Brno: Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. 2026."],"dc:identifier.other":["176070"],"dc:identifier.uri":["http://hdl.handle.net/11012/257332"],"dc:language":["angličtina (English)"],"dc:language.iso":["en"],"dc:publisher":["Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií"],"dc:publisher.faculty":["Fakulta elektrotechniky a komunikačních technologií"],"dc:rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"dc:subject":["FMCW radar","MIMO System","vital signs monitoring"],"dc:title":["Radar-Based Vital Signs Sensing in Vehicles"],"dc:title.alternative":["Radar-Based Vital Signs Sensing in Vehicles"],"dc:type":["Text","masterThesis","diplomová práce"],"others:access_status":["open.access"],"sync:item.dbid":["176070"],"sync:item.dbtype":["ZP"],"sync:item.insts":["2026.07.07 19:03:24"],"sync:item.modts":["2026.07.07 13:18:23"],"thesis:defence_status":["práce byla úspěšně obhájena"],"thesis:degree_discipline":["bez specializace"],"thesis:degree_level":["Inženýrský"],"thesis:degree_program":["Kybernetika, automatizace a měření"],"thesis:examination_report":["Student odprezentoval svou práci a zodpověděl otázky oponenta. Proběhla diskuse ohledně zohlednění variability srdečního cyklu při analýze a ohledně použitých metod detekce. Student komisí vyzdvižené nedostatky práce u obhajoby nezastíral, stejně jako v práci. Komise se ptala na porovnání s referenčním sensorem, které však provedeno v práci s relevantním snímačem nebylo."],"thesis:institution_name":["Ing.","Vysoké učení technické v Brně. Fakulta elektrotechniky a komunikačních technologií. Ústav automatizace a měřicí techniky"]},"updated_at":"2026-11-19T04:12:05Z"}