{"id":{"repo_id":"brno-tech","oai_identifier":"oai:dspace.vut.cz:11012/259960"},"canonical_url":"https://search.ndltd.org/etd/brno-tech/oai:dspace.vut.cz:11012/259960","repository":{"repo_id":"brno-tech","name":"Brno University of Technology","base_url":"https://dspace.vut.cz/oai/request"},"display":{"title":"Dopad kapky na porézní oxid železa: VOF simulace","abstract":"Droplet impact on the porous iron oxide layer is a multiphase flow problem of practical significance in spray cooling, in which the cooling spray interacts with the oxide skin formed on the surface of high-temperature metal. This paper adopts the Volume of Fluid (VOF) method realized in the open source CFD software OpenFOAM, combined with the MULES algorithm for interface capture and continuous surface force model for surface tension calculation, and conducts a numerical study of this phenomenon. All solid surfaces have a static contact angle of 20°, which is consistent with the hydrophilicity of iron oxide. The porous oxide layer is represented by a pore-resolved computational mesh instead of a volume-averaged continuum model. The grid is reconstructed from the micrograph stack of the actual oxide sample: the micrograph image is loaded into ParaView, resampled to the uniform OpenFOAM grid through the ResampleWithDataset function, denoising with a median filter, and the solid and pore regions are separated by applying an intensity threshold. The generated oxide geometry is embedded in the refined background grid through the mergeMeshes and stitchMesh functions, thus forming a single composite domain. A reference case of droplet diameter D0 = 0.1 mm and impact speed U0 = 1 m/s was established and extended it through two parameters: one is the speed parameter, U0 is 1, 2, 5 and 10 m/s respectively; the other is the droplet size parameter D0, with values of 0.1, 0.3 and 1 mm, the latter of which is obtained by rescaling the geometry using the transformPoints function. Pore penetration is quantified by two indicators extracted along the internal reference path of the oxide: the maximum penetration depth d(t) and the interface position through specific path dint (t) that changes with time. These two indicators together reveal that the early inertial dominant stage is followed by a slower capillary-driven phase. The grid of the reference case was refined to verify the sensitivity of the grid, the current non-convergence is due to several factors, which are discussed below.","abstract_html":"Droplet impact on the porous iron oxide layer is a multiphase flow problem of practical significance in spray cooling, in which the cooling spray interacts with the oxide skin formed on the surface of high-temperature metal. This paper adopts the Volume of Fluid (VOF) method realized in the open source CFD software OpenFOAM, combined with the MULES algorithm for interface capture and continuous surface force model for surface tension calculation, and conducts a numerical study of this phenomenon. All solid surfaces have a static contact angle of 20°, which is consistent with the hydrophilicity of iron oxide. The porous oxide layer is represented by a pore-resolved computational mesh instead of a volume-averaged continuum model. The grid is reconstructed from the micrograph stack of the actual oxide sample: the micrograph image is loaded into ParaView, resampled to the uniform OpenFOAM grid through the ResampleWithDataset function, denoising with a median filter, and the solid and pore regions are separated by applying an intensity threshold. The generated oxide geometry is embedded in the refined background grid through the mergeMeshes and stitchMesh functions, thus forming a single composite domain. A reference case of droplet diameter D0 = 0.1 mm and impact speed U0 = 1 m/s was established and extended it through two parameters: one is the speed parameter, U0 is 1, 2, 5 and 10 m/s respectively; the other is the droplet size parameter D0, with values of 0.1, 0.3 and 1 mm, the latter of which is obtained by rescaling the geometry using the transformPoints function. Pore penetration is quantified by two indicators extracted along the internal reference path of the oxide: the maximum penetration depth d(t) and the interface position through specific path dint (t) that changes with time. These two indicators together reveal that the early inertial dominant stage is followed by a slower capillary-driven phase. The grid of the reference case was refined to verify the sensitivity of the grid, the current non-convergence is due to several factors, which are discussed below.","abstract_has_math":false,"creators":["Cheng, Xin"],"institution":"Vysoké učení technické v Brně. Fakulta strojního inženýrství","degree_name":null,"degree_level":"Inženýrský","degree_discipline":"bez specializace","degree_department":null,"school":null,"contributors":[],"advisors":["Boháček, Jan"],"committee_chairs":[],"committee_members":["Hvožďa, Jiří","doc. Ing. Pavel Charvát, Ph.D. (předseda) prof. Ing. Pavel Novotný, Ph.D. (místopředseda) doc. Ing. František Lízal, Ph.D. (člen) doc. Ing. Vít Jan, Ph.D. (člen) doc. Ing. Jiří Šremr, Ph.D. (člen) doc. Ing. Pavel Rudolf, Ph.D. (člen)"],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T04:04:56Z","subjects":["Volume of Fluid (VOF)","Droplet impingement","Porous iron-oxide layer","OpenFOAM"],"languages":["en","angličtina (English)"],"rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["CHENG, X. Dopad kapky na porézní oxid železa: VOF simulace [online]. Brno: Vysoké učení technické v Brně. Fakulta strojního inženýrství. 2026."],"render_values":[{"text":"CHENG, X. Dopad kapky na porézní oxid železa: VOF simulace [online]. Brno: Vysoké učení technické v Brně. Fakulta strojního inženýrství. 2026.","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["174991"],"render_values":[{"text":"174991","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/11012/259960","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/11012/259960","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abrno-tech%3Aoai%3Adspace.vut.cz%3A11012%2F259960","prefix":"oai_dc"},"source_record":{"url":"https://dspace.vut.cz/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.vut.cz%3A11012%2F259960","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Boháček, Jan"]},{"key":"dc:contributor.committee","label":"Committee Member","values":["doc. Ing. Pavel Charvát, Ph.D. (předseda) prof. Ing. Pavel Novotný, Ph.D. (místopředseda) doc. Ing. František Lízal, Ph.D. (člen) doc. Ing. Vít Jan, Ph.D. (člen) doc. Ing. Jiří Šremr, Ph.D. (člen) doc. Ing. Pavel Rudolf, Ph.D. (člen)"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hvožďa, Jiří"]},{"key":"dc:creator","label":"Author","values":["Cheng, Xin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.acceptance","label":"Dc Date Acceptance","values":["2026-06-17"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-06-18-08:50:10"]},{"key":"dc:publisher","label":"Institution","values":["Vysoké učení technické v Brně. Fakulta strojního inženýrství"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Fakulta strojního inženýrství"]},{"key":"dc:type","label":"Dc Type","values":["Text","masterThesis","diplomová práce"]},{"key":"thesis:defence_status","label":"Thesis Defence Status","values":["práce byla úspěšně obhájena"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["bez specializace"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Inženýrský"]},{"key":"thesis:degree_program","label":"Thesis Degree Program","values":["Mechanical Engineering"]},{"key":"thesis:examination_report","label":"Thesis Examination Report","values":["The student presented the committee with the progress of the work, the results and conclusions of the thesis, and answered the supervisor's and reviewer's questions. During the defence, the student was unable to fully defend the work and did not demonstrate command of the details of the simulation; although the work employed an advanced simulation, the student was not fully familiar with its underlying details. Doc. Lízal asked about the experimental validation of the student's simulations. The student stated that no experimental work had been carried out. When asked which experimental methods could at least be used for some form of validation, the student was unable to identify any suitable method. Prof. Novotný asked whether the model was a 2D model or a genuinely axisymmetric one, and since the student had described it as axisymmetric, where the axis was located. The student indicated the position of the axis, after which the committee discussed the boundary conditions and the simulation setup. Prof. Novotný further asked which turbulence models the student had used. The student had not considered turbulence and had modelled laminar flow only. The committee discussed the suitability of this approach for the given simulation. Doc. Rudolf commented on the work and its conclusions and asked whether the velocities used were relevant to real applications. The student responded that 5 m/s was realistic. In response to a further question on whether a contact angle of 20° was realistic, the student noted that 20° could be realistic if the surface were heated. Doc. Jan asked about the physical background, namely, what happens when a liquid enters a very small, very hot pore, and how rapid the evaporation of the liquid would be. The student assumed that evaporation would be slow. Doc. Jan then asked whether the time required for the liquid to evaporate could be estimated by a simple calculation, and whether it would be on the order of milliseconds or hundreds of milliseconds. The student was unable to answer; even when guided by Doc. Jan towards thermomechanics, the student drew a T–s diagram but could not arrive at a solution. Doc. Lízal commented that the calorimetric equation might be suitable here."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Ing.","Vysoké učení technické v Brně. Fakulta strojního inženýrství. Laboratoř přenosu tepla a proudění"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Volume of Fluid (VOF)","Droplet impingement","Porous iron-oxide layer","OpenFOAM"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["angličtina (English)"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Standardní licenční smlouva - přístup k plnému textu bez omezení"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["CHENG, X. Dopad kapky na porézní oxid železa: VOF simulace [online]. Brno: Vysoké učení technické v Brně. Fakulta strojního inženýrství. 2026."]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["174991"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11012/259960"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Droplet impact on the porous iron oxide layer is a multiphase flow problem of practical significance in spray cooling, in which the cooling spray interacts with the oxide skin formed on the surface of high-temperature metal. This paper adopts the Volume of Fluid (VOF) method realized in the open source CFD software OpenFOAM, combined with the MULES algorithm for interface capture and continuous surface force model for surface tension calculation, and conducts a numerical study of this phenomenon. All solid surfaces have a static contact angle of 20°, which is consistent with the hydrophilicity of iron oxide. The porous oxide layer is represented by a pore-resolved computational mesh instead of a volume-averaged continuum model. The grid is reconstructed from the micrograph stack of the actual oxide sample: the micrograph image is loaded into ParaView, resampled to the uniform OpenFOAM grid through the ResampleWithDataset function, denoising with a median filter, and the solid and pore regions are separated by applying an intensity threshold. The generated oxide geometry is embedded in the refined background grid through the mergeMeshes and stitchMesh functions, thus forming a single composite domain. A reference case of droplet diameter D0 = 0.1 mm and impact speed U0 = 1 m/s was established and extended it through two parameters: one is the speed parameter, U0 is 1, 2, 5 and 10 m/s respectively; the other is the droplet size parameter D0, with values of 0.1, 0.3 and 1 mm, the latter of which is obtained by rescaling the geometry using the transformPoints function. Pore penetration is quantified by two indicators extracted along the internal reference path of the oxide: the maximum penetration depth d(t) and the interface position through specific path dint (t) that changes with time. These two indicators together reveal that the early inertial dominant stage is followed by a slower capillary-driven phase. The grid of the reference case was refined to verify the sensitivity of the grid, the current non-convergence is due to several factors, which are discussed below."]},{"key":"dc:description.grade","label":"Dc Description Grade","values":["D"]},{"key":"dc:title","label":"Title","values":["Dopad kapky na porézní oxid železa: VOF simulace"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Droplet Impingement on the Porous Iron Oxide Layer: VOF Simulation"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]},{"key":"sync:item.dbid","label":"Sync Item Dbid","values":["174991"]},{"key":"sync:item.dbtype","label":"Sync Item Dbtype","values":["ZP"]},{"key":"sync:item.insts","label":"Sync Item Insts","values":["2026.07.07 21:03:49"]},{"key":"sync:item.modts","label":"Sync Item Modts","values":["2026.07.07 12:38:02"]}]}],"canonical_facts":{"dc:contributor.advisor":["Boháček, Jan"],"dc:contributor.committee":["doc. Ing. Pavel Charvát, Ph.D. (předseda) prof. Ing. Pavel Novotný, Ph.D. (místopředseda) doc. Ing. František Lízal, Ph.D. (člen) doc. Ing. Vít Jan, Ph.D. (člen) doc. Ing. Jiří Šremr, Ph.D. (člen) doc. Ing. Pavel Rudolf, Ph.D. (člen)"],"dc:contributor.committeemember":["Hvožďa, Jiří"],"dc:creator":["Cheng, Xin"],"dc:date.acceptance":["2026-06-17"],"dc:date.created":["2026"],"dc:date.updated":["2026-06-18-08:50:10"],"dc:description.abstract":["Droplet impact on the porous iron oxide layer is a multiphase flow problem of practical significance in spray cooling, in which the cooling spray interacts with the oxide skin formed on the surface of high-temperature metal. This paper adopts the Volume of Fluid (VOF) method realized in the open source CFD software OpenFOAM, combined with the MULES algorithm for interface capture and continuous surface force model for surface tension calculation, and conducts a numerical study of this phenomenon. All solid surfaces have a static contact angle of 20°, which is consistent with the hydrophilicity of iron oxide. The porous oxide layer is represented by a pore-resolved computational mesh instead of a volume-averaged continuum model. The grid is reconstructed from the micrograph stack of the actual oxide sample: the micrograph image is loaded into ParaView, resampled to the uniform OpenFOAM grid through the ResampleWithDataset function, denoising with a median filter, and the solid and pore regions are separated by applying an intensity threshold. The generated oxide geometry is embedded in the refined background grid through the mergeMeshes and stitchMesh functions, thus forming a single composite domain. A reference case of droplet diameter D0 = 0.1 mm and impact speed U0 = 1 m/s was established and extended it through two parameters: one is the speed parameter, U0 is 1, 2, 5 and 10 m/s respectively; the other is the droplet size parameter D0, with values of 0.1, 0.3 and 1 mm, the latter of which is obtained by rescaling the geometry using the transformPoints function. Pore penetration is quantified by two indicators extracted along the internal reference path of the oxide: the maximum penetration depth d(t) and the interface position through specific path dint (t) that changes with time. These two indicators together reveal that the early inertial dominant stage is followed by a slower capillary-driven phase. The grid of the reference case was refined to verify the sensitivity of the grid, the current non-convergence is due to several factors, which are discussed below."],"dc:description.grade":["D"],"dc:identifier.citation":["CHENG, X. Dopad kapky na porézní oxid železa: VOF simulace [online]. Brno: Vysoké učení technické v Brně. Fakulta strojního inženýrství. 2026."],"dc:identifier.other":["174991"],"dc:identifier.uri":["http://hdl.handle.net/11012/259960"],"dc:language":["angličtina (English)"],"dc:language.iso":["en"],"dc:publisher":["Vysoké učení technické v Brně. Fakulta strojního inženýrství"],"dc:publisher.faculty":["Fakulta strojního inženýrství"],"dc:rights":["Standardní licenční smlouva - přístup k plnému textu bez omezení"],"dc:subject":["Volume of Fluid (VOF)","Droplet impingement","Porous iron-oxide layer","OpenFOAM"],"dc:title":["Dopad kapky na porézní oxid železa: VOF simulace"],"dc:title.alternative":["Droplet Impingement on the Porous Iron Oxide Layer: VOF Simulation"],"dc:type":["Text","masterThesis","diplomová práce"],"others:access_status":["open.access"],"sync:item.dbid":["174991"],"sync:item.dbtype":["ZP"],"sync:item.insts":["2026.07.07 21:03:49"],"sync:item.modts":["2026.07.07 12:38:02"],"thesis:defence_status":["práce byla úspěšně obhájena"],"thesis:degree_discipline":["bez specializace"],"thesis:degree_level":["Inženýrský"],"thesis:degree_program":["Mechanical Engineering"],"thesis:examination_report":["The student presented the committee with the progress of the work, the results and conclusions of the thesis, and answered the supervisor's and reviewer's questions. During the defence, the student was unable to fully defend the work and did not demonstrate command of the details of the simulation; although the work employed an advanced simulation, the student was not fully familiar with its underlying details. Doc. Lízal asked about the experimental validation of the student's simulations. The student stated that no experimental work had been carried out. When asked which experimental methods could at least be used for some form of validation, the student was unable to identify any suitable method. Prof. Novotný asked whether the model was a 2D model or a genuinely axisymmetric one, and since the student had described it as axisymmetric, where the axis was located. The student indicated the position of the axis, after which the committee discussed the boundary conditions and the simulation setup. Prof. Novotný further asked which turbulence models the student had used. The student had not considered turbulence and had modelled laminar flow only. The committee discussed the suitability of this approach for the given simulation. Doc. Rudolf commented on the work and its conclusions and asked whether the velocities used were relevant to real applications. The student responded that 5 m/s was realistic. In response to a further question on whether a contact angle of 20° was realistic, the student noted that 20° could be realistic if the surface were heated. Doc. Jan asked about the physical background, namely, what happens when a liquid enters a very small, very hot pore, and how rapid the evaporation of the liquid would be. The student assumed that evaporation would be slow. Doc. Jan then asked whether the time required for the liquid to evaporate could be estimated by a simple calculation, and whether it would be on the order of milliseconds or hundreds of milliseconds. The student was unable to answer; even when guided by Doc. Jan towards thermomechanics, the student drew a T–s diagram but could not arrive at a solution. Doc. Lízal commented that the calorimetric equation might be suitable here."],"thesis:institution_name":["Ing.","Vysoké učení technické v Brně. Fakulta strojního inženýrství. Laboratoř přenosu tepla a proudění"]},"updated_at":"2026-11-19T04:04:56Z"}