{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/14631"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/14631","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Combined conjugate and pupil adaptive optics in widefield microscopy","abstract":"Traditionally, adaptive optics (AO) systems for microscopy have focused on AO at the pupil plane, however this produces poor performance in samples with both spatially-variant aberrations, such as non-flat sample interfaces, and spatially-invariant aberrations, such as spherical aberration due to a difference between the sample index of refraction and the sample for which the objective was designed. Here, we demonstrate well-corrected, wide field-of-view (FOV) microscopy by simultaneously correcting the two types of aberrations using two AO loops. Such an approach is necessary in wide-field applications where both types of aberration may be present, as each AO loop can only fully correct one type of aberration. Wide FOV corrections are demonstrated in a trans-illumination microscope equipped with two deformable mirrors (DMs), using a partitioned aperture wavefront (PAW) sensor to directly control the DM conjugated to the sample interface and a sensor-less genetic algorithm to control the DM conjugated to the objective’s pupil.","abstract_html":"Traditionally, adaptive optics (AO) systems for microscopy have focused on AO at the pupil plane, however this produces poor performance in samples with both spatially-variant aberrations, such as non-flat sample interfaces, and spatially-invariant aberrations, such as spherical aberration due to a difference between the sample index of refraction and the sample for which the objective was designed. Here, we demonstrate well-corrected, wide field-of-view (FOV) microscopy by simultaneously correcting the two types of aberrations using two AO loops. Such an approach is necessary in wide-field applications where both types of aberration may be present, as each AO loop can only fully correct one type of aberration. Wide FOV corrections are demonstrated in a trans-illumination microscope equipped with two deformable mirrors (DMs), using a partitioned aperture wavefront (PAW) sensor to directly control the DM conjugated to the sample interface and a sensor-less genetic algorithm to control the DM conjugated to the objective’s pupil.","abstract_has_math":false,"creators":["Beaulieu, Devin Robert"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical & Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-18T19:49:29Z","subjects":["Optics","Microscopy","Adaptive optics","Wavefront sensing"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/14631","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/14631","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F14631","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Beaulieu, Devin Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-02-26T16:49:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-02-26T16:49:05Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-02-17T23:19:02Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical & Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Optics","Microscopy","Adaptive optics","Wavefront sensing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/14631"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Traditionally, adaptive optics (AO) systems for microscopy have focused on AO at the pupil plane, however this produces poor performance in samples with both spatially-variant aberrations, such as non-flat sample interfaces, and spatially-invariant aberrations, such as spherical aberration due to a difference between the sample index of refraction and the sample for which the objective was designed. Here, we demonstrate well-corrected, wide field-of-view (FOV) microscopy by simultaneously correcting the two types of aberrations using two AO loops. Such an approach is necessary in wide-field applications where both types of aberration may be present, as each AO loop can only fully correct one type of aberration. Wide FOV corrections are demonstrated in a trans-illumination microscope equipped with two deformable mirrors (DMs), using a partitioned aperture wavefront (PAW) sensor to directly control the DM conjugated to the sample interface and a sensor-less genetic algorithm to control the DM conjugated to the objective’s pupil."]},{"key":"dc:title","label":"Title","values":["Combined conjugate and pupil adaptive optics in widefield microscopy"]}]}],"canonical_facts":{"dc:creator":["Beaulieu, Devin Robert"],"dc:date.accessioned":["2016-02-26T16:49:05Z"],"dc:date.available":["2016-02-26T16:49:05Z"],"dc:date.issued":["2016"],"dc:date.updated":["2016-02-17T23:19:02Z"],"dc:description.abstract":["Traditionally, adaptive optics (AO) systems for microscopy have focused on AO at the pupil plane, however this produces poor performance in samples with both spatially-variant aberrations, such as non-flat sample interfaces, and spatially-invariant aberrations, such as spherical aberration due to a difference between the sample index of refraction and the sample for which the objective was designed. Here, we demonstrate well-corrected, wide field-of-view (FOV) microscopy by simultaneously correcting the two types of aberrations using two AO loops. Such an approach is necessary in wide-field applications where both types of aberration may be present, as each AO loop can only fully correct one type of aberration. Wide FOV corrections are demonstrated in a trans-illumination microscope equipped with two deformable mirrors (DMs), using a partitioned aperture wavefront (PAW) sensor to directly control the DM conjugated to the sample interface and a sensor-less genetic algorithm to control the DM conjugated to the objective’s pupil."],"dc:identifier.uri":["https://hdl.handle.net/2144/14631"],"dc:language.iso":["en_US"],"dc:subject":["Optics","Microscopy","Adaptive optics","Wavefront sensing"],"dc:title":["Combined conjugate and pupil adaptive optics in widefield microscopy"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Electrical & Computer Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:49:29Z"}