{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/18731"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/18731","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Flexural strength and marginal fit of two types of lithium disilicate ceramics for crowns","abstract":"OBJECTIVES: To evaluate the flexural strength of 5 ceramic dental materials and to compare the marginal fit of crowns made with e.max press and a new experimental (EXP) press ceramic. MATERIALS AND METHODS: The materials tested for flexural strength included: E.max press, E.maxCAD, ENAMIC, Experimental press, and Experimental-CAD. Each group (N= 10) was tested using the Instron 5566A using the piston-on-three-balls test. For the crown fit experiment an Ivorine tooth was prepared with a chamfer finish and used as the master die. Wax up crowns were made on the die and pressed with E.max press and the Experimental press. 5 crowns per material were obtained. A similar procedure was used with standard aluminum crown dies. Copings were waxed up and pressed: 3 copings of E.max and 6 copings of EXP. Eight measurements of marginal fit per restoration were obtained with an optical microscope at 200×. The data was analyzed using ANOVA and a post hoc Tukey-HSD test (Significance level = 0.05). RESULTS: Mean and SD Flexural Strength values (MPa) per group were: E.max press: 486.96 (30.42). EXP press 378.16 (88.13). E.maxCAD 493.28 (55.2). EXP-CAD 420.63 (86.05). ENAMIC 157.59 (6.27). Mean and SD values for margin fit per group (Microns) were: E.max press 74 (19). EXP press 65 (19). CONCLUSIONS: E.max press has 28.8% higher FS than EXP press (P=0.0044). ENAMIC had the lower FS (as expected). EXP press had significantly lower marginal gap than E.max press by 12.2%.","abstract_html":"OBJECTIVES: To evaluate the flexural strength of 5 ceramic dental materials and to compare the marginal fit of crowns made with e.max press and a new experimental (EXP) press ceramic. MATERIALS AND METHODS: The materials tested for flexural strength included: E.max press, E.maxCAD, ENAMIC, Experimental press, and Experimental-CAD. Each group (N= 10) was tested using the Instron 5566A using the piston-on-three-balls test. For the crown fit experiment an Ivorine tooth was prepared with a chamfer finish and used as the master die. Wax up crowns were made on the die and pressed with E.max press and the Experimental press. 5 crowns per material were obtained. A similar procedure was used with standard aluminum crown dies. Copings were waxed up and pressed: 3 copings of E.max and 6 copings of EXP. Eight measurements of marginal fit per restoration were obtained with an optical microscope at 200×. The data was analyzed using ANOVA and a post hoc Tukey-HSD test (Significance level = 0.05). RESULTS: Mean and SD Flexural Strength values (MPa) per group were: E.max press: 486.96 (30.42). EXP press 378.16 (88.13). E.maxCAD 493.28 (55.2). EXP-CAD 420.63 (86.05). ENAMIC 157.59 (6.27). Mean and SD values for margin fit per group (Microns) were: E.max press 74 (19). EXP press 65 (19). CONCLUSIONS: E.max press has 28.8% higher FS than EXP press (P=0.0044). ENAMIC had the lower FS (as expected). EXP press had significantly lower marginal gap than E.max press by 12.2%.","abstract_has_math":false,"creators":["Munguia, Gerardo"],"institution":"Boston University","degree_name":"Master of Science in Design","degree_level":"masters","degree_discipline":"Restorative Sciences & Biomaterials","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T02:39:56Z","subjects":["Dentistry","Flexural strength","Glass ceramics","Lithium disilicate","Marginal discrepancy","Marginal fit"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/18731","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/18731","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F18731","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Munguia, Gerardo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-10-26T18:32:57Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2018-09-28T00:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2016-09-28T16:09:08Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Restorative Sciences & Biomaterials"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Design"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry","Flexural strength","Glass ceramics","Lithium disilicate","Marginal discrepancy","Marginal fit"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/18731"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["OBJECTIVES: To evaluate the flexural strength of 5 ceramic dental materials and to compare the marginal fit of crowns made with e.max press and a new experimental (EXP) press ceramic. MATERIALS AND METHODS: The materials tested for flexural strength included: E.max press, E.maxCAD, ENAMIC, Experimental press, and Experimental-CAD. Each group (N= 10) was tested using the Instron 5566A using the piston-on-three-balls test. For the crown fit experiment an Ivorine tooth was prepared with a chamfer finish and used as the master die. Wax up crowns were made on the die and pressed with E.max press and the Experimental press. 5 crowns per material were obtained. A similar procedure was used with standard aluminum crown dies. Copings were waxed up and pressed: 3 copings of E.max and 6 copings of EXP. Eight measurements of marginal fit per restoration were obtained with an optical microscope at 200×. The data was analyzed using ANOVA and a post hoc Tukey-HSD test (Significance level = 0.05). RESULTS: Mean and SD Flexural Strength values (MPa) per group were: E.max press: 486.96 (30.42). EXP press 378.16 (88.13). E.maxCAD 493.28 (55.2). EXP-CAD 420.63 (86.05). ENAMIC 157.59 (6.27). Mean and SD values for margin fit per group (Microns) were: E.max press 74 (19). EXP press 65 (19). CONCLUSIONS: E.max press has 28.8% higher FS than EXP press (P=0.0044). ENAMIC had the lower FS (as expected). EXP press had significantly lower marginal gap than E.max press by 12.2%."]},{"key":"dc:title","label":"Title","values":["Flexural strength and marginal fit of two types of lithium disilicate ceramics for crowns"]}]}],"canonical_facts":{"dc:creator":["Munguia, Gerardo"],"dc:date.accessioned":["2016-10-26T18:32:57Z"],"dc:date.embargo":["2018-09-28T00:00:00Z"],"dc:date.issued":["2016"],"dc:date.updated":["2016-09-28T16:09:08Z"],"dc:description.abstract":["OBJECTIVES: To evaluate the flexural strength of 5 ceramic dental materials and to compare the marginal fit of crowns made with e.max press and a new experimental (EXP) press ceramic. MATERIALS AND METHODS: The materials tested for flexural strength included: E.max press, E.maxCAD, ENAMIC, Experimental press, and Experimental-CAD. Each group (N= 10) was tested using the Instron 5566A using the piston-on-three-balls test. For the crown fit experiment an Ivorine tooth was prepared with a chamfer finish and used as the master die. Wax up crowns were made on the die and pressed with E.max press and the Experimental press. 5 crowns per material were obtained. A similar procedure was used with standard aluminum crown dies. Copings were waxed up and pressed: 3 copings of E.max and 6 copings of EXP. Eight measurements of marginal fit per restoration were obtained with an optical microscope at 200×. The data was analyzed using ANOVA and a post hoc Tukey-HSD test (Significance level = 0.05). RESULTS: Mean and SD Flexural Strength values (MPa) per group were: E.max press: 486.96 (30.42). EXP press 378.16 (88.13). E.maxCAD 493.28 (55.2). EXP-CAD 420.63 (86.05). ENAMIC 157.59 (6.27). Mean and SD values for margin fit per group (Microns) were: E.max press 74 (19). EXP press 65 (19). CONCLUSIONS: E.max press has 28.8% higher FS than EXP press (P=0.0044). ENAMIC had the lower FS (as expected). EXP press had significantly lower marginal gap than E.max press by 12.2%."],"dc:identifier.uri":["https://hdl.handle.net/2144/18731"],"dc:language.iso":["en_US"],"dc:subject":["Dentistry","Flexural strength","Glass ceramics","Lithium disilicate","Marginal discrepancy","Marginal fit"],"dc:title":["Flexural strength and marginal fit of two types of lithium disilicate ceramics for crowns"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Restorative Sciences & Biomaterials"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Design"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-19T02:39:56Z"}