{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/26400"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/26400","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Mechanical properties of interim restorative materials: conventional vs. CAD/CAM","abstract":"To determine the effects of thermal accelerated aging on flexural strength and flexural modulus of conventional and CAD/CAM provisional crown and bridge restorative materials. Six provisional crown and bridge materials were selected for this study. Three conventional resins: Jet Set 4 (Lang), Luxatemp (DMG), and Protemp Plus (3M ESPE); and three CAD/CAM materials: ArtBloc Temp (Merz), Telio CAD-Temp (Ivoclar Vivadent), and Vita CAD-Temp (Vita). Specimens of conventional materials were fabricated using a custom-made aluminum mold 25 2 2 mm. CAD/CAM blocks were sectioned to the same dimensions. A total of 180 bar-shaped specimens were obtained (30 of each material) and were divided into three groups per treatment. Groups 1 and 2 were immersed in 37°C water for 24 hours, and 6 days, respectively. Group 3 was subjected to 5,000 thermal cycles between 5°C and 55°C in water with 35 seconds dwelling time. All specimens where tested for flexural properties using three-point bending protocol on an Instron 5566A at a crosshead speed of 0.5mm/min. The results were analyzed by one-way ANOVA and post hoc Tukey test with material type and aging conditions as the main variables. Significance level was set at (p<0.05). Overall CAD/CAM materials demonstrated significantly higher flexural strength and flexural modulus over conventional resins. No significant difference in flexural strength and flexural modulus was found among three treatments except for: Luxatemp, which showed significant increased flexural strength and flexural modulus after thermal cycling, and Protemp Plus which showed increased flexural strength after 6 days of water storage.","abstract_html":"To determine the effects of thermal accelerated aging on flexural strength and flexural modulus of conventional and CAD/CAM provisional crown and bridge restorative materials. Six provisional crown and bridge materials were selected for this study. Three conventional resins: Jet Set 4 (Lang), Luxatemp (DMG), and Protemp Plus (3M ESPE); and three CAD/CAM materials: ArtBloc Temp (Merz), Telio CAD-Temp (Ivoclar Vivadent), and Vita CAD-Temp (Vita). Specimens of conventional materials were fabricated using a custom-made aluminum mold 25 2 2 mm. CAD/CAM blocks were sectioned to the same dimensions. A total of 180 bar-shaped specimens were obtained (30 of each material) and were divided into three groups per treatment. Groups 1 and 2 were immersed in 37°C water for 24 hours, and 6 days, respectively. Group 3 was subjected to 5,000 thermal cycles between 5°C and 55°C in water with 35 seconds dwelling time. All specimens where tested for flexural properties using three-point bending protocol on an Instron 5566A at a crosshead speed of 0.5mm/min. The results were analyzed by one-way ANOVA and post hoc Tukey test with material type and aging conditions as the main variables. Significance level was set at (p&lt;0.05). Overall CAD/CAM materials demonstrated significantly higher flexural strength and flexural modulus over conventional resins. No significant difference in flexural strength and flexural modulus was found among three treatments except for: Luxatemp, which showed significant increased flexural strength and flexural modulus after thermal cycling, and Protemp Plus which showed increased flexural strength after 6 days of water storage.","abstract_has_math":false,"creators":["Odisho, Walter E."],"institution":"Boston University","degree_name":"Master of Science in Design","degree_level":"masters","degree_discipline":"Restorative Sciences & Biomaterials","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-18T19:51:09Z","subjects":["Dentistry","CAD/CAM","Flexural modulus","Flexural strength","Interim provisional restorations","Provisional restorations"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/26400","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/26400","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F26400","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Odisho, Walter E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-01-25T15:30:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-01-25T15:30:43Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2017-10-25T18:37:11Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Restorative Sciences & Biomaterials"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Design"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry","CAD/CAM","Flexural modulus","Flexural strength","Interim provisional restorations","Provisional restorations"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/26400"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["To determine the effects of thermal accelerated aging on flexural strength and flexural modulus of conventional and CAD/CAM provisional crown and bridge restorative materials. Six provisional crown and bridge materials were selected for this study. Three conventional resins: Jet Set 4 (Lang), Luxatemp (DMG), and Protemp Plus (3M ESPE); and three CAD/CAM materials: ArtBloc Temp (Merz), Telio CAD-Temp (Ivoclar Vivadent), and Vita CAD-Temp (Vita). Specimens of conventional materials were fabricated using a custom-made aluminum mold 25 2 2 mm. CAD/CAM blocks were sectioned to the same dimensions. A total of 180 bar-shaped specimens were obtained (30 of each material) and were divided into three groups per treatment. Groups 1 and 2 were immersed in 37°C water for 24 hours, and 6 days, respectively. Group 3 was subjected to 5,000 thermal cycles between 5°C and 55°C in water with 35 seconds dwelling time. All specimens where tested for flexural properties using three-point bending protocol on an Instron 5566A at a crosshead speed of 0.5mm/min. The results were analyzed by one-way ANOVA and post hoc Tukey test with material type and aging conditions as the main variables. Significance level was set at (p<0.05). Overall CAD/CAM materials demonstrated significantly higher flexural strength and flexural modulus over conventional resins. No significant difference in flexural strength and flexural modulus was found among three treatments except for: Luxatemp, which showed significant increased flexural strength and flexural modulus after thermal cycling, and Protemp Plus which showed increased flexural strength after 6 days of water storage."]},{"key":"dc:title","label":"Title","values":["Mechanical properties of interim restorative materials: conventional vs. CAD/CAM"]}]}],"canonical_facts":{"dc:creator":["Odisho, Walter E."],"dc:date.accessioned":["2018-01-25T15:30:43Z"],"dc:date.available":["2018-01-25T15:30:43Z"],"dc:date.issued":["2017"],"dc:date.updated":["2017-10-25T18:37:11Z"],"dc:description.abstract":["To determine the effects of thermal accelerated aging on flexural strength and flexural modulus of conventional and CAD/CAM provisional crown and bridge restorative materials. Six provisional crown and bridge materials were selected for this study. Three conventional resins: Jet Set 4 (Lang), Luxatemp (DMG), and Protemp Plus (3M ESPE); and three CAD/CAM materials: ArtBloc Temp (Merz), Telio CAD-Temp (Ivoclar Vivadent), and Vita CAD-Temp (Vita). Specimens of conventional materials were fabricated using a custom-made aluminum mold 25 2 2 mm. CAD/CAM blocks were sectioned to the same dimensions. A total of 180 bar-shaped specimens were obtained (30 of each material) and were divided into three groups per treatment. Groups 1 and 2 were immersed in 37°C water for 24 hours, and 6 days, respectively. Group 3 was subjected to 5,000 thermal cycles between 5°C and 55°C in water with 35 seconds dwelling time. All specimens where tested for flexural properties using three-point bending protocol on an Instron 5566A at a crosshead speed of 0.5mm/min. The results were analyzed by one-way ANOVA and post hoc Tukey test with material type and aging conditions as the main variables. Significance level was set at (p<0.05). Overall CAD/CAM materials demonstrated significantly higher flexural strength and flexural modulus over conventional resins. No significant difference in flexural strength and flexural modulus was found among three treatments except for: Luxatemp, which showed significant increased flexural strength and flexural modulus after thermal cycling, and Protemp Plus which showed increased flexural strength after 6 days of water storage."],"dc:identifier.uri":["https://hdl.handle.net/2144/26400"],"dc:language.iso":["en_US"],"dc:subject":["Dentistry","CAD/CAM","Flexural modulus","Flexural strength","Interim provisional restorations","Provisional restorations"],"dc:title":["Mechanical properties of interim restorative materials: conventional vs. CAD/CAM"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Restorative Sciences & Biomaterials"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Design"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:51:09Z"}