{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/27570"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/27570","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Comparison of piezoimplants versus conventional cylindrical implants in minipigs: stability analysis","abstract":"AIM: To compare the stability of a non-cylindrical implant using piezoelectric drilling (Piezoimplant) with a cylindrical implant with conventional drilling (Nobel Biocare™). MATERIALS AND METHODS: Three adult female Gottingen miniature pigs were used for the surgical implantation. Three implants on each quadrant, randomized split-mouth design using cylindrical or non-cylindrical implants (n=36). Osteotomies were prepared using either conventional drilling technique as per manufacturer’s instruction (Nobel Biocare™) or using piezoelectric drilling (Piezotome® (P2) (Satelec Acteon, Merignac, France) with new implant prototype tips (Fraunhofer Center for Manufacturing Innovation). The minipigs were sacrificed at 4, 8 and 12-weeks. Stability tests (three per implant) using wireless Periotest® “M” were done at the start point and after euthanization. RESULTS: R-square (ANOVA) test was plotted comparing implant design, weeks 4, 8 and 12, and location (mandible and maxilla) for stability analysis. In this model, the R-square is only 0.51, which indicates only 51% of the response variability can be explained by the fitted model. Among all the 3 factors, group (experiment vs control) is the most significant one, followed by week. Location significance is the least among the three factors. CONCLUSION: In mandibular and maxillary sites in minipigs where non-cylindrical prototype implants (piezoimplant) were inserted by piezoelectric site preparation, statistically significant differences were found between control and test group stability measurements, but no differences in week (4, 8 or 12) and location among the two groups (mandible and maxilla). Stability was like the cylindrical implants. Meaning that Piezoimplants could be an alternative for narrow residual ridges.","abstract_html":"AIM: To compare the stability of a non-cylindrical implant using piezoelectric drilling (Piezoimplant) with a cylindrical implant with conventional drilling (Nobel Biocare™). MATERIALS AND METHODS: Three adult female Gottingen miniature pigs were used for the surgical implantation. Three implants on each quadrant, randomized split-mouth design using cylindrical or non-cylindrical implants (n=36). Osteotomies were prepared using either conventional drilling technique as per manufacturer’s instruction (Nobel Biocare™) or using piezoelectric drilling (Piezotome® (P2) (Satelec Acteon, Merignac, France) with new implant prototype tips (Fraunhofer Center for Manufacturing Innovation). The minipigs were sacrificed at 4, 8 and 12-weeks. Stability tests (three per implant) using wireless Periotest® “M” were done at the start point and after euthanization. RESULTS: R-square (ANOVA) test was plotted comparing implant design, weeks 4, 8 and 12, and location (mandible and maxilla) for stability analysis. In this model, the R-square is only 0.51, which indicates only 51% of the response variability can be explained by the fitted model. Among all the 3 factors, group (experiment vs control) is the most significant one, followed by week. Location significance is the least among the three factors. CONCLUSION: In mandibular and maxillary sites in minipigs where non-cylindrical prototype implants (piezoimplant) were inserted by piezoelectric site preparation, statistically significant differences were found between control and test group stability measurements, but no differences in week (4, 8 or 12) and location among the two groups (mandible and maxilla). Stability was like the cylindrical implants. Meaning that Piezoimplants could be an alternative for narrow residual ridges.","abstract_has_math":false,"creators":["Corzo, Lorena"],"institution":"Boston University","degree_name":"Master of Science in Design","degree_level":"masters","degree_discipline":"Periodontology","degree_department":null,"school":null,"contributors":[],"advisors":["Xu, Wanpeng"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T02:40:14Z","subjects":["Dentistry","Implants","Minipigs","Piezocision","Stability"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/27570","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/27570","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F27570","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Xu, Wanpeng"]},{"key":"dc:creator","label":"Author","values":["Corzo, Lorena"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-03-20T14:04:47Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2020-03-14T00:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-03-14T19:21:46Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Periodontology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Design"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry","Implants","Minipigs","Piezocision","Stability"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/27570"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["AIM: To compare the stability of a non-cylindrical implant using piezoelectric drilling (Piezoimplant) with a cylindrical implant with conventional drilling (Nobel Biocare™). MATERIALS AND METHODS: Three adult female Gottingen miniature pigs were used for the surgical implantation. Three implants on each quadrant, randomized split-mouth design using cylindrical or non-cylindrical implants (n=36). Osteotomies were prepared using either conventional drilling technique as per manufacturer’s instruction (Nobel Biocare™) or using piezoelectric drilling (Piezotome® (P2) (Satelec Acteon, Merignac, France) with new implant prototype tips (Fraunhofer Center for Manufacturing Innovation). The minipigs were sacrificed at 4, 8 and 12-weeks. Stability tests (three per implant) using wireless Periotest® “M” were done at the start point and after euthanization. RESULTS: R-square (ANOVA) test was plotted comparing implant design, weeks 4, 8 and 12, and location (mandible and maxilla) for stability analysis. In this model, the R-square is only 0.51, which indicates only 51% of the response variability can be explained by the fitted model. Among all the 3 factors, group (experiment vs control) is the most significant one, followed by week. Location significance is the least among the three factors. CONCLUSION: In mandibular and maxillary sites in minipigs where non-cylindrical prototype implants (piezoimplant) were inserted by piezoelectric site preparation, statistically significant differences were found between control and test group stability measurements, but no differences in week (4, 8 or 12) and location among the two groups (mandible and maxilla). Stability was like the cylindrical implants. Meaning that Piezoimplants could be an alternative for narrow residual ridges."]},{"key":"dc:title","label":"Title","values":["Comparison of piezoimplants versus conventional cylindrical implants in minipigs: stability analysis"]}]}],"canonical_facts":{"dc:contributor.advisor":["Xu, Wanpeng"],"dc:creator":["Corzo, Lorena"],"dc:date.accessioned":["2018-03-20T14:04:47Z"],"dc:date.embargo":["2020-03-14T00:00:00Z"],"dc:date.issued":["2018"],"dc:date.updated":["2018-03-14T19:21:46Z"],"dc:description.abstract":["AIM: To compare the stability of a non-cylindrical implant using piezoelectric drilling (Piezoimplant) with a cylindrical implant with conventional drilling (Nobel Biocare™). MATERIALS AND METHODS: Three adult female Gottingen miniature pigs were used for the surgical implantation. Three implants on each quadrant, randomized split-mouth design using cylindrical or non-cylindrical implants (n=36). Osteotomies were prepared using either conventional drilling technique as per manufacturer’s instruction (Nobel Biocare™) or using piezoelectric drilling (Piezotome® (P2) (Satelec Acteon, Merignac, France) with new implant prototype tips (Fraunhofer Center for Manufacturing Innovation). The minipigs were sacrificed at 4, 8 and 12-weeks. Stability tests (three per implant) using wireless Periotest® “M” were done at the start point and after euthanization. RESULTS: R-square (ANOVA) test was plotted comparing implant design, weeks 4, 8 and 12, and location (mandible and maxilla) for stability analysis. In this model, the R-square is only 0.51, which indicates only 51% of the response variability can be explained by the fitted model. Among all the 3 factors, group (experiment vs control) is the most significant one, followed by week. Location significance is the least among the three factors. CONCLUSION: In mandibular and maxillary sites in minipigs where non-cylindrical prototype implants (piezoimplant) were inserted by piezoelectric site preparation, statistically significant differences were found between control and test group stability measurements, but no differences in week (4, 8 or 12) and location among the two groups (mandible and maxilla). Stability was like the cylindrical implants. Meaning that Piezoimplants could be an alternative for narrow residual ridges."],"dc:identifier.uri":["https://hdl.handle.net/2144/27570"],"dc:language.iso":["en_US"],"dc:subject":["Dentistry","Implants","Minipigs","Piezocision","Stability"],"dc:title":["Comparison of piezoimplants versus conventional cylindrical implants in minipigs: stability analysis"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Periodontology"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Design"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-19T02:40:14Z"}