{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/30060"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/30060","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Microleakage of temporary restorations in endodontically accessed teeth; thermocycling, brushing, and coating effects: an in vitro study","abstract":"OBJECTIVES: To evaluate in vitro the coronal leakage of endodontically treated teeth sealed with temporary restorative materials with or without coating sealants, and subjected to brushing and thermocycling. MATERIALS AND METHODS: One hundred two extracted human premolars and molars, were endodontically accessed, and restored with 3 types of temporary restorations: 1. Cavit (3M ESPE), 2. Ketac Molar (3M ESPE), 3. Riva Light Cure GlC (SDI). Each type of restoration had one subgroup with a coating (Cavit-Ketac Glaze, Ketac Molar- Ketac Glaze, Riva Light Cure GIC – Riva Coat) and the other without coating. Restored teeth were placed in artificial saliva at 37°C for 24 hours. Teeth were divided into 3 treatment subgroups: Group A: No treatment, soaked at 37° C artificial saliva; Group B: Teeth underwent thermocycling; Group C: teeth underwent both thermocycling and brushing. Thermocycling included 500 cycles between 5°C to 55°C. Tooth brushing was simulated in a brushing machine using 190g weight applied to 16,800 linear strokes. The control group was not exposed to thermocycling or brushing. Leakage was detected by immersion of specimens in 2% methylene blue dye for 24 hours. Specimens were epoxy embedded and sectioned longitudinally. The leakage scores were evaluated from photographs by longitudinal dye penetration depth scored 0 for no leakage and 4 for maximum leakage to the bottom of restoration. Statistical analysis was done to examine the effect of coating and post-treatment on leakage scores. RESULTS: All tested temporary restorative materials with coating had lower leakage than without coating in all experimental groups. CONCLUSIONS: The leakage of temporary restorative materials can be reduced by surface coating, however, thermocycling and brushing treatment can still generate some leakage.","abstract_html":"OBJECTIVES: To evaluate in vitro the coronal leakage of endodontically treated teeth sealed with temporary restorative materials with or without coating sealants, and subjected to brushing and thermocycling. MATERIALS AND METHODS: One hundred two extracted human premolars and molars, were endodontically accessed, and restored with 3 types of temporary restorations: 1. Cavit (3M ESPE), 2. Ketac Molar (3M ESPE), 3. Riva Light Cure GlC (SDI). Each type of restoration had one subgroup with a coating (Cavit-Ketac Glaze, Ketac Molar- Ketac Glaze, Riva Light Cure GIC – Riva Coat) and the other without coating. Restored teeth were placed in artificial saliva at 37°C for 24 hours. Teeth were divided into 3 treatment subgroups: Group A: No treatment, soaked at 37° C artificial saliva; Group B: Teeth underwent thermocycling; Group C: teeth underwent both thermocycling and brushing. Thermocycling included 500 cycles between 5°C to 55°C. Tooth brushing was simulated in a brushing machine using 190g weight applied to 16,800 linear strokes. The control group was not exposed to thermocycling or brushing. Leakage was detected by immersion of specimens in 2% methylene blue dye for 24 hours. Specimens were epoxy embedded and sectioned longitudinally. The leakage scores were evaluated from photographs by longitudinal dye penetration depth scored 0 for no leakage and 4 for maximum leakage to the bottom of restoration. Statistical analysis was done to examine the effect of coating and post-treatment on leakage scores. RESULTS: All tested temporary restorative materials with coating had lower leakage than without coating in all experimental groups. CONCLUSIONS: The leakage of temporary restorative materials can be reduced by surface coating, however, thermocycling and brushing treatment can still generate some leakage.","abstract_has_math":false,"creators":["Alenezi, Mona"],"institution":"Boston University","degree_name":"Master of Science in Design","degree_level":"masters","degree_discipline":"Endodontics","degree_department":null,"school":null,"contributors":[],"advisors":["Nathanson, Dan"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-19T02:40:17Z","subjects":["Dentistry","Coating","Leakage","Temporary restoration"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/30060","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/30060","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F30060","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Nathanson, Dan"]},{"key":"dc:creator","label":"Author","values":["Alenezi, Mona"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-07-26T14:19:44Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2020-06-28T00:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2018-06-28T13:00:16Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Endodontics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Design"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry","Coating","Leakage","Temporary restoration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/30060"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["OBJECTIVES: To evaluate in vitro the coronal leakage of endodontically treated teeth sealed with temporary restorative materials with or without coating sealants, and subjected to brushing and thermocycling. MATERIALS AND METHODS: One hundred two extracted human premolars and molars, were endodontically accessed, and restored with 3 types of temporary restorations: 1. Cavit (3M ESPE), 2. Ketac Molar (3M ESPE), 3. Riva Light Cure GlC (SDI). Each type of restoration had one subgroup with a coating (Cavit-Ketac Glaze, Ketac Molar- Ketac Glaze, Riva Light Cure GIC – Riva Coat) and the other without coating. Restored teeth were placed in artificial saliva at 37°C for 24 hours. Teeth were divided into 3 treatment subgroups: Group A: No treatment, soaked at 37° C artificial saliva; Group B: Teeth underwent thermocycling; Group C: teeth underwent both thermocycling and brushing. Thermocycling included 500 cycles between 5°C to 55°C. Tooth brushing was simulated in a brushing machine using 190g weight applied to 16,800 linear strokes. The control group was not exposed to thermocycling or brushing. Leakage was detected by immersion of specimens in 2% methylene blue dye for 24 hours. Specimens were epoxy embedded and sectioned longitudinally. The leakage scores were evaluated from photographs by longitudinal dye penetration depth scored 0 for no leakage and 4 for maximum leakage to the bottom of restoration. Statistical analysis was done to examine the effect of coating and post-treatment on leakage scores. RESULTS: All tested temporary restorative materials with coating had lower leakage than without coating in all experimental groups. CONCLUSIONS: The leakage of temporary restorative materials can be reduced by surface coating, however, thermocycling and brushing treatment can still generate some leakage."]},{"key":"dc:title","label":"Title","values":["Microleakage of temporary restorations in endodontically accessed teeth; thermocycling, brushing, and coating effects: an in vitro study"]}]}],"canonical_facts":{"dc:contributor.advisor":["Nathanson, Dan"],"dc:creator":["Alenezi, Mona"],"dc:date.accessioned":["2018-07-26T14:19:44Z"],"dc:date.embargo":["2020-06-28T00:00:00Z"],"dc:date.issued":["2018"],"dc:date.updated":["2018-06-28T13:00:16Z"],"dc:description.abstract":["OBJECTIVES: To evaluate in vitro the coronal leakage of endodontically treated teeth sealed with temporary restorative materials with or without coating sealants, and subjected to brushing and thermocycling. MATERIALS AND METHODS: One hundred two extracted human premolars and molars, were endodontically accessed, and restored with 3 types of temporary restorations: 1. Cavit (3M ESPE), 2. Ketac Molar (3M ESPE), 3. Riva Light Cure GlC (SDI). Each type of restoration had one subgroup with a coating (Cavit-Ketac Glaze, Ketac Molar- Ketac Glaze, Riva Light Cure GIC – Riva Coat) and the other without coating. Restored teeth were placed in artificial saliva at 37°C for 24 hours. Teeth were divided into 3 treatment subgroups: Group A: No treatment, soaked at 37° C artificial saliva; Group B: Teeth underwent thermocycling; Group C: teeth underwent both thermocycling and brushing. Thermocycling included 500 cycles between 5°C to 55°C. Tooth brushing was simulated in a brushing machine using 190g weight applied to 16,800 linear strokes. The control group was not exposed to thermocycling or brushing. Leakage was detected by immersion of specimens in 2% methylene blue dye for 24 hours. Specimens were epoxy embedded and sectioned longitudinally. The leakage scores were evaluated from photographs by longitudinal dye penetration depth scored 0 for no leakage and 4 for maximum leakage to the bottom of restoration. Statistical analysis was done to examine the effect of coating and post-treatment on leakage scores. RESULTS: All tested temporary restorative materials with coating had lower leakage than without coating in all experimental groups. CONCLUSIONS: The leakage of temporary restorative materials can be reduced by surface coating, however, thermocycling and brushing treatment can still generate some leakage."],"dc:identifier.uri":["https://hdl.handle.net/2144/30060"],"dc:language.iso":["en_US"],"dc:subject":["Dentistry","Coating","Leakage","Temporary restoration"],"dc:title":["Microleakage of temporary restorations in endodontically accessed teeth; thermocycling, brushing, and coating effects: an in vitro study"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Endodontics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Design"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-19T02:40:17Z"}