{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/31834"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/31834","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"A volumetric analysis of sulcular fluid flow relative to teeth undergoing periodontal prosthesis","abstract":"This study was undertaken to determine whether there was any volumetric change in the amount of sulcular fluid flow in the gingival crevice, prior to, and subsequent to the placement of fixed periodontal prostheses. The volume of sulcuf ar fluid was measured and assayed by the use of disposable plastic syringes graded in millimeters: I. Prior to tooth preparation. II. Approximately two to four weeks after temporization of individual and multiple prosthetic abutments. III. Approximately two weeks after final insertion of fixed prosthesis. The study was performed on ten human patients in clinical periodontal health. The results statistically showed that the amount of fluid flow increased after temporization of prosthetic abutments and decreased slightly following insertion of the final fixed prosthesis.","abstract_html":"This study was undertaken to determine whether there was any volumetric change in the amount of sulcular fluid flow in the gingival crevice, prior to, and subsequent to the placement of fixed periodontal prostheses. The volume of sulcuf ar fluid was measured and assayed by the use of disposable plastic syringes graded in millimeters: I. Prior to tooth preparation. II. Approximately two to four weeks after temporization of individual and multiple prosthetic abutments. III. Approximately two weeks after final insertion of fixed prosthesis. The study was performed on ten human patients in clinical periodontal health. The results statistically showed that the amount of fluid flow increased after temporization of prosthetic abutments and decreased slightly following insertion of the final fixed prosthesis.","abstract_has_math":false,"creators":["Holmes, Thomas F.","Watkin, Arnold"],"institution":"Boston University","degree_name":"Master of Science in Dentistry","degree_level":"masters","degree_discipline":"Periodontics and Prosthodontics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1971,"date_issued":"1971","date_published":"1971","updated_at":"2026-11-18T20:24:00Z","subjects":["Gingiva","Periodontal prosthesis"],"languages":["en_US"],"rights":["This work is being made available in OpenBU by permission of its author, and is available for research purposes only. All rights are reserved to the author."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["16016918","b14337630"],"render_values":[{"text":"16016918","href":null,"code":true},{"text":"b14337630","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/31834","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/31834","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F31834","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Holmes, Thomas F.","Watkin, Arnold"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-10-31T16:04:53Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2018-10-31T16:04:53Z"]},{"key":"dc:date.issued","label":"Date","values":["1971"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["1971"]},{"key":"dc:publisher","label":"Institution","values":["Boston University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Periodontics and Prosthodontics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Dentistry"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Gingiva","Periodontal prosthesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["This work is being made available in OpenBU by permission of its author, and is available for research purposes only. All rights are reserved to the author."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["16016918","b14337630"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/31834"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M.Sc.D.)--Boston University, School of Graduate Dentistry, 1971.","Bibliography included."]},{"key":"dc:description.abstract","label":"Abstract","values":["This study was undertaken to determine whether there was any volumetric change in the amount of sulcular fluid flow in the gingival crevice, prior to, and subsequent to the placement of fixed periodontal prostheses. The volume of sulcuf ar fluid was measured and assayed by the use of disposable plastic syringes graded in millimeters: I. Prior to tooth preparation. II. Approximately two to four weeks after temporization of individual and multiple prosthetic abutments. III. Approximately two weeks after final insertion of fixed prosthesis. The study was performed on ten human patients in clinical periodontal health. The results statistically showed that the amount of fluid flow increased after temporization of prosthetic abutments and decreased slightly following insertion of the final fixed prosthesis."]},{"key":"dc:title","label":"Title","values":["A volumetric analysis of sulcular fluid flow relative to teeth undergoing periodontal prosthesis"]}]}],"canonical_facts":{"dc:creator":["Holmes, Thomas F.","Watkin, Arnold"],"dc:date.accessioned":["2018-10-31T16:04:53Z"],"dc:date.available":["2018-10-31T16:04:53Z"],"dc:date.issued":["1971"],"dc:date.submitted":["1971"],"dc:description":["Thesis (M.Sc.D.)--Boston University, School of Graduate Dentistry, 1971.","Bibliography included."],"dc:description.abstract":["This study was undertaken to determine whether there was any volumetric change in the amount of sulcular fluid flow in the gingival crevice, prior to, and subsequent to the placement of fixed periodontal prostheses. The volume of sulcuf ar fluid was measured and assayed by the use of disposable plastic syringes graded in millimeters: I. Prior to tooth preparation. II. Approximately two to four weeks after temporization of individual and multiple prosthetic abutments. III. Approximately two weeks after final insertion of fixed prosthesis. The study was performed on ten human patients in clinical periodontal health. The results statistically showed that the amount of fluid flow increased after temporization of prosthetic abutments and decreased slightly following insertion of the final fixed prosthesis."],"dc:identifier.other":["16016918","b14337630"],"dc:identifier.uri":["https://hdl.handle.net/2144/31834"],"dc:language.iso":["en_US"],"dc:publisher":["Boston University"],"dc:rights":["This work is being made available in OpenBU by permission of its author, and is available for research purposes only. All rights are reserved to the author."],"dc:subject":["Gingiva","Periodontal prosthesis"],"dc:title":["A volumetric analysis of sulcular fluid flow relative to teeth undergoing periodontal prosthesis"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Periodontics and Prosthodontics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Dentistry"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T20:24:00Z"}