{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/32037"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/32037","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Quantitative MRI quality control using the ACR phantom","abstract":"Recently, many studies have used T1 and T2 quantitative MRI in examining the brain and other body structures, to evaluate and follow up diseases, or simply for better understanding of the human body. Quality control on MRI scanners has been performed since the early eighties and nowadays the ACR MRI phantom is being used for the accreditation of the scanners, and quality control of their qualitative performance. In this study the same phantom is being used to obtain quantitative values of three regions in the phantom that might be used as reference for quantitative quality control. The results of the scans provided quantitative values that can be used as reference for the quality control of qMRI, and there was no difference after scanning the same regions twice. Further study is recommended to provide quantitative values for different MRI scanners strength to assure the use of ACR phantom as a tool for quality control of qMRI scanners.","abstract_html":"Recently, many studies have used T1 and T2 quantitative MRI in examining the brain and other body structures, to evaluate and follow up diseases, or simply for better understanding of the human body. Quality control on MRI scanners has been performed since the early eighties and nowadays the ACR MRI phantom is being used for the accreditation of the scanners, and quality control of their qualitative performance. In this study the same phantom is being used to obtain quantitative values of three regions in the phantom that might be used as reference for quantitative quality control. The results of the scans provided quantitative values that can be used as reference for the quality control of qMRI, and there was no difference after scanning the same regions twice. Further study is recommended to provide quantitative values for different MRI scanners strength to assure the use of ACR phantom as a tool for quality control of qMRI scanners.","abstract_has_math":false,"creators":["Al Mohammad, Badera"],"institution":"Boston University","degree_name":"Master of Arts","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-19T02:40:35Z","subjects":["MRI scanners","ACR MRI phantom"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.barcode","label":"Dc Identifier Barcode","values":["11719026843096"],"render_values":[{"text":"11719026843096","href":null,"code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["99185411840001161"],"render_values":[{"text":"99185411840001161","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["b38091355"],"render_values":[{"text":"b38091355","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/32037","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/32037","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":"embargoed","embargo_until":"2999-01-01","access_note":"Embargoed until 2999-01-01"},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F32037","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Al Mohammad, Badera"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2018-11-07T15:59:48Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2999-01-01"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Boston University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Arts"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["MRI scanners","ACR MRI phantom"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.barcode","label":"Dc Identifier Barcode","values":["11719026843096"]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["99185411840001161"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["b38091355"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/32037"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M.A.)--Boston University","PLEASE NOTE: Boston University Libraries did not receive an Authorization To Manage form for this thesis or dissertation. It is therefore not openly accessible, though it may be available by request. If you are the author or principal advisor of this work and would like to request open access for it, please contact us at open-help@bu.edu. Thank you."]},{"key":"dc:description.abstract","label":"Abstract","values":["Recently, many studies have used T1 and T2 quantitative MRI in examining the brain and other body structures, to evaluate and follow up diseases, or simply for better understanding of the human body. Quality control on MRI scanners has been performed since the early eighties and nowadays the ACR MRI phantom is being used for the accreditation of the scanners, and quality control of their qualitative performance. In this study the same phantom is being used to obtain quantitative values of three regions in the phantom that might be used as reference for quantitative quality control. The results of the scans provided quantitative values that can be used as reference for the quality control of qMRI, and there was no difference after scanning the same regions twice. Further study is recommended to provide quantitative values for different MRI scanners strength to assure the use of ACR phantom as a tool for quality control of qMRI scanners."]},{"key":"dc:title","label":"Title","values":["Quantitative MRI quality control using the ACR phantom"]}]}],"canonical_facts":{"dc:creator":["Al Mohammad, Badera"],"dc:date.accessioned":["2018-11-07T15:59:48Z"],"dc:date.embargo":["2999-01-01"],"dc:date.issued":["2012"],"dc:date.submitted":["2012"],"dc:description":["Thesis (M.A.)--Boston University","PLEASE NOTE: Boston University Libraries did not receive an Authorization To Manage form for this thesis or dissertation. It is therefore not openly accessible, though it may be available by request. If you are the author or principal advisor of this work and would like to request open access for it, please contact us at open-help@bu.edu. Thank you."],"dc:description.abstract":["Recently, many studies have used T1 and T2 quantitative MRI in examining the brain and other body structures, to evaluate and follow up diseases, or simply for better understanding of the human body. Quality control on MRI scanners has been performed since the early eighties and nowadays the ACR MRI phantom is being used for the accreditation of the scanners, and quality control of their qualitative performance. In this study the same phantom is being used to obtain quantitative values of three regions in the phantom that might be used as reference for quantitative quality control. The results of the scans provided quantitative values that can be used as reference for the quality control of qMRI, and there was no difference after scanning the same regions twice. Further study is recommended to provide quantitative values for different MRI scanners strength to assure the use of ACR phantom as a tool for quality control of qMRI scanners."],"dc:identifier.barcode":["11719026843096"],"dc:identifier.bibid":["99185411840001161"],"dc:identifier.other":["b38091355"],"dc:identifier.uri":["https://hdl.handle.net/2144/32037"],"dc:language.iso":["en_US"],"dc:publisher":["Boston University"],"dc:subject":["MRI scanners","ACR MRI phantom"],"dc:title":["Quantitative MRI quality control using the ACR phantom"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Arts"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-19T02:40:35Z"}