{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/36021"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/36021","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Förster resonance energy transfer (FRET) as an optical readout for transcription factor-DNA binding in biosensing applications","abstract":"An alternative molecular recognition approach was developed for sensing small molecule analytes using the differential binding of an allosteric transcription factor (TF, specifically TetR) to its cognate DNA as the molecular recognition element coupled with Förster resonance energy transfer (FRET) to yield an internally calibrated optical signal transduction mechanism. Sensors were evaluated comprising Cy5-modified DNA (FRET acceptor) with either a tdTomato-TetR fusion protein (FP-TF) or quantum dot-TetR conjugate (QD-TF) as the FRET donor by measuring the ratio of acceptor and donor fluorescence intensities (FA/FD) with titrations of a derivative of the antibiotic tetracycline, anhydrous tetracycline (aTc). A proof-of-concept FRET-based biosensor was successfully demonstrated through the modulation of FA/FD signal intensities based on varying analyte concentrations. Sensor design parameters affecting overall signal-to-noise ratio and sensitivity of the sensors are also identified.","abstract_html":"An alternative molecular recognition approach was developed for sensing small molecule analytes using the differential binding of an allosteric transcription factor (TF, specifically TetR) to its cognate DNA as the molecular recognition element coupled with Förster resonance energy transfer (FRET) to yield an internally calibrated optical signal transduction mechanism. Sensors were evaluated comprising Cy5-modified DNA (FRET acceptor) with either a tdTomato-TetR fusion protein (FP-TF) or quantum dot-TetR conjugate (QD-TF) as the FRET donor by measuring the ratio of acceptor and donor fluorescence intensities (FA/FD) with titrations of a derivative of the antibiotic tetracycline, anhydrous tetracycline (aTc). A proof-of-concept FRET-based biosensor was successfully demonstrated through the modulation of FA/FD signal intensities based on varying analyte concentrations. Sensor design parameters affecting overall signal-to-noise ratio and sensitivity of the sensors are also identified.","abstract_has_math":false,"creators":["Nguyen, Thuy Thi Ha"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Dennis, Allison"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T02:41:09Z","subjects":["Biomedical engineering","Affinity","Assay","Homogenous assay","Nanoparticle","Quantum dot","Small molecule analyte"],"languages":["en_US"],"rights":["Attribution-NonCommercial 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/36021","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/36021","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F36021","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dennis, Allison"]},{"key":"dc:creator","label":"Author","values":["Nguyen, Thuy Thi Ha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-06-20T18:16:47Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2020-06-03T00:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-06-04T01:05:13Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical engineering","Affinity","Assay","Homogenous assay","Nanoparticle","Quantum dot","Small molecule analyte"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by-nc/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/36021"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An alternative molecular recognition approach was developed for sensing small molecule analytes using the differential binding of an allosteric transcription factor (TF, specifically TetR) to its cognate DNA as the molecular recognition element coupled with Förster resonance energy transfer (FRET) to yield an internally calibrated optical signal transduction mechanism. Sensors were evaluated comprising Cy5-modified DNA (FRET acceptor) with either a tdTomato-TetR fusion protein (FP-TF) or quantum dot-TetR conjugate (QD-TF) as the FRET donor by measuring the ratio of acceptor and donor fluorescence intensities (FA/FD) with titrations of a derivative of the antibiotic tetracycline, anhydrous tetracycline (aTc). A proof-of-concept FRET-based biosensor was successfully demonstrated through the modulation of FA/FD signal intensities based on varying analyte concentrations. Sensor design parameters affecting overall signal-to-noise ratio and sensitivity of the sensors are also identified."]},{"key":"dc:title","label":"Title","values":["Förster resonance energy transfer (FRET) as an optical readout for transcription factor-DNA binding in biosensing applications"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dennis, Allison"],"dc:creator":["Nguyen, Thuy Thi Ha"],"dc:date.accessioned":["2019-06-20T18:16:47Z"],"dc:date.embargo":["2020-06-03T00:00:00Z"],"dc:date.issued":["2019"],"dc:date.updated":["2019-06-04T01:05:13Z"],"dc:description.abstract":["An alternative molecular recognition approach was developed for sensing small molecule analytes using the differential binding of an allosteric transcription factor (TF, specifically TetR) to its cognate DNA as the molecular recognition element coupled with Förster resonance energy transfer (FRET) to yield an internally calibrated optical signal transduction mechanism. Sensors were evaluated comprising Cy5-modified DNA (FRET acceptor) with either a tdTomato-TetR fusion protein (FP-TF) or quantum dot-TetR conjugate (QD-TF) as the FRET donor by measuring the ratio of acceptor and donor fluorescence intensities (FA/FD) with titrations of a derivative of the antibiotic tetracycline, anhydrous tetracycline (aTc). A proof-of-concept FRET-based biosensor was successfully demonstrated through the modulation of FA/FD signal intensities based on varying analyte concentrations. Sensor design parameters affecting overall signal-to-noise ratio and sensitivity of the sensors are also identified."],"dc:identifier.uri":["https://hdl.handle.net/2144/36021"],"dc:language.iso":["en_US"],"dc:rights":["Attribution-NonCommercial 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by-nc/4.0/"],"dc:subject":["Biomedical engineering","Affinity","Assay","Homogenous assay","Nanoparticle","Quantum dot","Small molecule analyte"],"dc:title":["Förster resonance energy transfer (FRET) as an optical readout for transcription factor-DNA binding in biosensing applications"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-19T02:41:09Z"}