{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/38738"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/38738","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Evaluation of D-dimer in postmortem blood using the SERATEC PMB Test","abstract":"Biological material is a common type of evidence found at a crime scene, and body fluid identification is an essential process in crime scene investigation. One of the most common types of body fluids found is blood. After a stain has been presumptively identified as blood through the use of a colorimetric chemical test, additional testing may be necessary to better characterize the stain. SERATEC PMB Test is a relatively new lateral flow immunochromatographic assay that targets human hemoglobin and D-dimer simultaneously in order to distinguish peripheral blood and menstrual blood at the same time. Elevated levels of D-dimer, a fibrin degradation product, are found in menstrual blood, thrombosis formation and as part of the postmortem process. A previous study investigated levels of D-dimer in menstrual, peripheral and postmortem blood using the SERATEC PMB Test. In this study, all postmortem blood samples showed positive results for both hemoglobin and D-dimer; all peripheral bloodstain samples from living individuals showed positive results for hemoglobin detection, and negative results for D-dimer detection; and most menstrual bloodstain samples showed positive D-dimer results. The results suggest that this assay could be considered a presumptive test for both postmortem blood and menstrual blood. However, as D-dimer concentrations vary between individuals, additional testing is necessary to conclusively distinguish postmortem blood, menstrual blood and peripheral blood from living individuals with especially high D-dimer levels.","abstract_html":"Biological material is a common type of evidence found at a crime scene, and body fluid identification is an essential process in crime scene investigation. One of the most common types of body fluids found is blood. After a stain has been presumptively identified as blood through the use of a colorimetric chemical test, additional testing may be necessary to better characterize the stain. SERATEC PMB Test is a relatively new lateral flow immunochromatographic assay that targets human hemoglobin and D-dimer simultaneously in order to distinguish peripheral blood and menstrual blood at the same time. Elevated levels of D-dimer, a fibrin degradation product, are found in menstrual blood, thrombosis formation and as part of the postmortem process. A previous study investigated levels of D-dimer in menstrual, peripheral and postmortem blood using the SERATEC PMB Test. In this study, all postmortem blood samples showed positive results for both hemoglobin and D-dimer; all peripheral bloodstain samples from living individuals showed positive results for hemoglobin detection, and negative results for D-dimer detection; and most menstrual bloodstain samples showed positive D-dimer results. The results suggest that this assay could be considered a presumptive test for both postmortem blood and menstrual blood. However, as D-dimer concentrations vary between individuals, additional testing is necessary to conclusively distinguish postmortem blood, menstrual blood and peripheral blood from living individuals with especially high D-dimer levels.","abstract_has_math":false,"creators":["Wang, Huxi"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Forensic Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Brodeur, Amy N."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-18T20:21:04Z","subjects":["Biology","D-dimer","Fibrinolysis","Forensics","Immunochromatographic assay","Menstrual blood","Postmortem blood"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"dc:identifier.orcid","label":"ORCID","values":["0000-0002-8707-1375"],"render_values":[{"text":"0000-0002-8707-1375","href":"https://orcid.org/0000-0002-8707-1375","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/2144/38738","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/38738","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F38738","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brodeur, Amy N."]},{"key":"dc:creator","label":"Author","values":["Wang, Huxi"]},{"key":"dc:identifier.orcid","label":"ORCID","values":["0000-0002-8707-1375"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-12-11T18:49:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-12-11T18:49:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-11-09T02:01:13Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Forensic Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biology","D-dimer","Fibrinolysis","Forensics","Immunochromatographic assay","Menstrual blood","Postmortem blood"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/38738"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Biological material is a common type of evidence found at a crime scene, and body fluid identification is an essential process in crime scene investigation. One of the most common types of body fluids found is blood. After a stain has been presumptively identified as blood through the use of a colorimetric chemical test, additional testing may be necessary to better characterize the stain. SERATEC PMB Test is a relatively new lateral flow immunochromatographic assay that targets human hemoglobin and D-dimer simultaneously in order to distinguish peripheral blood and menstrual blood at the same time. Elevated levels of D-dimer, a fibrin degradation product, are found in menstrual blood, thrombosis formation and as part of the postmortem process. A previous study investigated levels of D-dimer in menstrual, peripheral and postmortem blood using the SERATEC PMB Test. In this study, all postmortem blood samples showed positive results for both hemoglobin and D-dimer; all peripheral bloodstain samples from living individuals showed positive results for hemoglobin detection, and negative results for D-dimer detection; and most menstrual bloodstain samples showed positive D-dimer results. The results suggest that this assay could be considered a presumptive test for both postmortem blood and menstrual blood. However, as D-dimer concentrations vary between individuals, additional testing is necessary to conclusively distinguish postmortem blood, menstrual blood and peripheral blood from living individuals with especially high D-dimer levels."]},{"key":"dc:title","label":"Title","values":["Evaluation of D-dimer in postmortem blood using the SERATEC PMB Test"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brodeur, Amy N."],"dc:creator":["Wang, Huxi"],"dc:date.accessioned":["2019-12-11T18:49:13Z"],"dc:date.available":["2019-12-11T18:49:13Z"],"dc:date.issued":["2019"],"dc:date.updated":["2019-11-09T02:01:13Z"],"dc:description.abstract":["Biological material is a common type of evidence found at a crime scene, and body fluid identification is an essential process in crime scene investigation. One of the most common types of body fluids found is blood. After a stain has been presumptively identified as blood through the use of a colorimetric chemical test, additional testing may be necessary to better characterize the stain. SERATEC PMB Test is a relatively new lateral flow immunochromatographic assay that targets human hemoglobin and D-dimer simultaneously in order to distinguish peripheral blood and menstrual blood at the same time. Elevated levels of D-dimer, a fibrin degradation product, are found in menstrual blood, thrombosis formation and as part of the postmortem process. A previous study investigated levels of D-dimer in menstrual, peripheral and postmortem blood using the SERATEC PMB Test. In this study, all postmortem blood samples showed positive results for both hemoglobin and D-dimer; all peripheral bloodstain samples from living individuals showed positive results for hemoglobin detection, and negative results for D-dimer detection; and most menstrual bloodstain samples showed positive D-dimer results. The results suggest that this assay could be considered a presumptive test for both postmortem blood and menstrual blood. However, as D-dimer concentrations vary between individuals, additional testing is necessary to conclusively distinguish postmortem blood, menstrual blood and peripheral blood from living individuals with especially high D-dimer levels."],"dc:identifier.orcid":["0000-0002-8707-1375"],"dc:identifier.uri":["https://hdl.handle.net/2144/38738"],"dc:language.iso":["en_US"],"dc:subject":["Biology","D-dimer","Fibrinolysis","Forensics","Immunochromatographic assay","Menstrual blood","Postmortem blood"],"dc:title":["Evaluation of D-dimer in postmortem blood using the SERATEC PMB Test"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Forensic Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T20:21:04Z"}