{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/40715"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/40715","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Optimization of microelectrode sensor sensitivity for real-time monitoring important physiological parameters of human renal epithelial cell","abstract":"In order to calculate specific impedance of cell-covered electrodes in a Equation of morphological parameters of cell per se, an ECIS model of Human Renal Epithelial Cell are created by analysis partial differential equations describing three intrinsic pathways of electrical currents in the system. Based on this cell model, this research explores how some adjustable dimensional parameters of electrode-configuration impact sensor sensitivity by changing the overall impedance contribution of electrical double layer. Namely, it includes electrode planner area, spacing between working and counter electrode and geometry of electrode, scanning frequency. Qualitative studies on how sensor sensitivity rely on configurational parameters are conducted with these parameters involved. Moreover, theoretical analysis of sensitivity by using equivalent circuit model is also carried out. As results of COMSOL simulations, special double layer electrode configurations and selectively planted cell monolayer arrangement are proposed regardless of fabrication difficulties. Accordingly, some possible strategies to make these arrangements come true are also illustrated. Finally, superior possible COMSOL simulation model is suggested and discussed for future optimization works.","abstract_html":"In order to calculate specific impedance of cell-covered electrodes in a Equation of morphological parameters of cell per se, an ECIS model of Human Renal Epithelial Cell are created by analysis partial differential equations describing three intrinsic pathways of electrical currents in the system. Based on this cell model, this research explores how some adjustable dimensional parameters of electrode-configuration impact sensor sensitivity by changing the overall impedance contribution of electrical double layer. Namely, it includes electrode planner area, spacing between working and counter electrode and geometry of electrode, scanning frequency. Qualitative studies on how sensor sensitivity rely on configurational parameters are conducted with these parameters involved. Moreover, theoretical analysis of sensitivity by using equivalent circuit model is also carried out. As results of COMSOL simulations, special double layer electrode configurations and selectively planted cell monolayer arrangement are proposed regardless of fabrication difficulties. Accordingly, some possible strategies to make these arrangements come true are also illustrated. Finally, superior possible COMSOL simulation model is suggested and discussed for future optimization works.","abstract_has_math":false,"creators":["Yuan, Fan"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Materials Science & Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Zhang, Xin"],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-19T02:41:25Z","subjects":["Bioengineering","COMSOL simulation","Finite element analysis","Human renal epithelial cell","Microelectrode sensor","Real-time monitoring","Sensor sensitivity"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"dc:identifier.orcid","label":"ORCID","values":["https://orcid.org/0000-0002-1174-2283"],"render_values":[{"text":"0000-0002-1174-2283","href":"https://orcid.org/0000-0002-1174-2283","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/2144/40715","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/40715","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F40715","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Zhang, Xin"]},{"key":"dc:creator","label":"Author","values":["Yuan, Fan"]},{"key":"dc:identifier.orcid","label":"ORCID","values":["https://orcid.org/0000-0002-1174-2283"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-05-08T17:04:13Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2021-05-07T00:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2020-05-07T22:02:15Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science & Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Bioengineering","COMSOL simulation","Finite element analysis","Human renal epithelial cell","Microelectrode sensor","Real-time monitoring","Sensor sensitivity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/40715"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In order to calculate specific impedance of cell-covered electrodes in a Equation of morphological parameters of cell per se, an ECIS model of Human Renal Epithelial Cell are created by analysis partial differential equations describing three intrinsic pathways of electrical currents in the system. Based on this cell model, this research explores how some adjustable dimensional parameters of electrode-configuration impact sensor sensitivity by changing the overall impedance contribution of electrical double layer. Namely, it includes electrode planner area, spacing between working and counter electrode and geometry of electrode, scanning frequency. Qualitative studies on how sensor sensitivity rely on configurational parameters are conducted with these parameters involved. Moreover, theoretical analysis of sensitivity by using equivalent circuit model is also carried out. As results of COMSOL simulations, special double layer electrode configurations and selectively planted cell monolayer arrangement are proposed regardless of fabrication difficulties. Accordingly, some possible strategies to make these arrangements come true are also illustrated. Finally, superior possible COMSOL simulation model is suggested and discussed for future optimization works."]},{"key":"dc:title","label":"Title","values":["Optimization of microelectrode sensor sensitivity for real-time monitoring important physiological parameters of human renal epithelial cell"]}]}],"canonical_facts":{"dc:contributor.advisor":["Zhang, Xin"],"dc:creator":["Yuan, Fan"],"dc:date.accessioned":["2020-05-08T17:04:13Z"],"dc:date.embargo":["2021-05-07T00:00:00Z"],"dc:date.issued":["2020"],"dc:date.updated":["2020-05-07T22:02:15Z"],"dc:description.abstract":["In order to calculate specific impedance of cell-covered electrodes in a Equation of morphological parameters of cell per se, an ECIS model of Human Renal Epithelial Cell are created by analysis partial differential equations describing three intrinsic pathways of electrical currents in the system. Based on this cell model, this research explores how some adjustable dimensional parameters of electrode-configuration impact sensor sensitivity by changing the overall impedance contribution of electrical double layer. Namely, it includes electrode planner area, spacing between working and counter electrode and geometry of electrode, scanning frequency. Qualitative studies on how sensor sensitivity rely on configurational parameters are conducted with these parameters involved. Moreover, theoretical analysis of sensitivity by using equivalent circuit model is also carried out. As results of COMSOL simulations, special double layer electrode configurations and selectively planted cell monolayer arrangement are proposed regardless of fabrication difficulties. Accordingly, some possible strategies to make these arrangements come true are also illustrated. Finally, superior possible COMSOL simulation model is suggested and discussed for future optimization works."],"dc:identifier.orcid":["https://orcid.org/0000-0002-1174-2283"],"dc:identifier.uri":["https://hdl.handle.net/2144/40715"],"dc:language.iso":["en_US"],"dc:subject":["Bioengineering","COMSOL simulation","Finite element analysis","Human renal epithelial cell","Microelectrode sensor","Real-time monitoring","Sensor sensitivity"],"dc:title":["Optimization of microelectrode sensor sensitivity for real-time monitoring important physiological parameters of human renal epithelial cell"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Materials Science & Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-19T02:41:25Z"}