{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/42177"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/42177","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"A review of substances reported to cause false positives and negatives in forensic blood identification tests","abstract":"Forensic biology encompasses the examination of evidentiary items from crime scenes for biological fluids, often identifying the specific biological fluid present and developing a DNA profile that can be used to link a suspect to a crime. Blood identification consists of visual examination, presumptive tests based on the catalytic activity of hemoglobin, and confirmatory tests based on antigen-antibody interactions. Issues encountered in blood identification include the occurrence of false positive and false negative results. Many causes of these results are well-known but more recently three substances resulting in false negatives with catalytic color tests, chemiluminescent reagents, and immunoassays have been explored. Quebracho extract (a common leather tannin), sodium percarbonate (the main component of detergents containing active oxygen) and vitamin C-containing beverages were all found to produce false negative results at varying degrees with each of the tests mentioned. Increased knowledge of potential negative interfering agents by forensic investigators can help ensure that probative evidence is properly collected and thoroughly analyzed from a crime scene.","abstract_html":"Forensic biology encompasses the examination of evidentiary items from crime scenes for biological fluids, often identifying the specific biological fluid present and developing a DNA profile that can be used to link a suspect to a crime. Blood identification consists of visual examination, presumptive tests based on the catalytic activity of hemoglobin, and confirmatory tests based on antigen-antibody interactions. Issues encountered in blood identification include the occurrence of false positive and false negative results. Many causes of these results are well-known but more recently three substances resulting in false negatives with catalytic color tests, chemiluminescent reagents, and immunoassays have been explored. Quebracho extract (a common leather tannin), sodium percarbonate (the main component of detergents containing active oxygen) and vitamin C-containing beverages were all found to produce false negative results at varying degrees with each of the tests mentioned. Increased knowledge of potential negative interfering agents by forensic investigators can help ensure that probative evidence is properly collected and thoroughly analyzed from a crime scene.","abstract_has_math":false,"creators":["Novelli, Brittany Catherine"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Forensic Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Brodeur, Amy N."],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-18T19:40:56Z","subjects":["Biology","Active oxygen","Ascorbic acid","False negative","False positive","Forensic biology","Leather tannin"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/42177","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/42177","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F42177","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brodeur, Amy N."]},{"key":"dc:creator","label":"Author","values":["Novelli, Brittany Catherine"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-03-02T18:56:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-03-02T18:56:17Z"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2021-02-26T02:01:56Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Forensic Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biology","Active oxygen","Ascorbic acid","False negative","False positive","Forensic biology","Leather tannin"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/42177"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Forensic biology encompasses the examination of evidentiary items from crime scenes for biological fluids, often identifying the specific biological fluid present and developing a DNA profile that can be used to link a suspect to a crime. Blood identification consists of visual examination, presumptive tests based on the catalytic activity of hemoglobin, and confirmatory tests based on antigen-antibody interactions. Issues encountered in blood identification include the occurrence of false positive and false negative results. Many causes of these results are well-known but more recently three substances resulting in false negatives with catalytic color tests, chemiluminescent reagents, and immunoassays have been explored. Quebracho extract (a common leather tannin), sodium percarbonate (the main component of detergents containing active oxygen) and vitamin C-containing beverages were all found to produce false negative results at varying degrees with each of the tests mentioned. Increased knowledge of potential negative interfering agents by forensic investigators can help ensure that probative evidence is properly collected and thoroughly analyzed from a crime scene."]},{"key":"dc:title","label":"Title","values":["A review of substances reported to cause false positives and negatives in forensic blood identification tests"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brodeur, Amy N."],"dc:creator":["Novelli, Brittany Catherine"],"dc:date.accessioned":["2021-03-02T18:56:17Z"],"dc:date.available":["2021-03-02T18:56:17Z"],"dc:date.issued":["2020"],"dc:date.updated":["2021-02-26T02:01:56Z"],"dc:description.abstract":["Forensic biology encompasses the examination of evidentiary items from crime scenes for biological fluids, often identifying the specific biological fluid present and developing a DNA profile that can be used to link a suspect to a crime. Blood identification consists of visual examination, presumptive tests based on the catalytic activity of hemoglobin, and confirmatory tests based on antigen-antibody interactions. Issues encountered in blood identification include the occurrence of false positive and false negative results. Many causes of these results are well-known but more recently three substances resulting in false negatives with catalytic color tests, chemiluminescent reagents, and immunoassays have been explored. Quebracho extract (a common leather tannin), sodium percarbonate (the main component of detergents containing active oxygen) and vitamin C-containing beverages were all found to produce false negative results at varying degrees with each of the tests mentioned. Increased knowledge of potential negative interfering agents by forensic investigators can help ensure that probative evidence is properly collected and thoroughly analyzed from a crime scene."],"dc:identifier.uri":["https://hdl.handle.net/2144/42177"],"dc:language.iso":["en_US"],"dc:subject":["Biology","Active oxygen","Ascorbic acid","False negative","False positive","Forensic biology","Leather tannin"],"dc:title":["A review of substances reported to cause false positives and negatives in forensic blood identification tests"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Forensic Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:40:56Z"}