{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/45667"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/45667","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Investigation of giant vacuoles in the inner wall endothelium of Schlemm's canal at physiologic pressure and comparison of the types and size of giant vacuoles in human eyes perfused at 7- and 15-mm Hg using serial block-face scanning electron microscopy","abstract":"Glaucoma is a disease characterized by elevated intra-ocular pressure and chronic, irreversible loss of vision. The precise mechanism by which outflow resistance is generated remains elusive. We investigated a unique structure called the giant vacuole (GV) in the inner wall endothelium of Schlemm’s canal (SC) that contribute to regulating outflow resistance. This study aimed to: 1) investigate the types and size of GVs in eyes perfused at 7 mmHg (physiological pressure in enucleated eyes) in the inner wall endothelium of SC using serial block-face scanning electron microscopy (SBF-SEM) and subsequent three-dimensional (3D) reconstruction of GVs; 2) to compare differences in the types and sizes of GVs in eyes perfused at 7 mmHg with published results in eyes perfused at 15 mm Hg (Swain et al, 2021). Two normal human donor eyes were perfused at 7 mmHg with fluorescent tracers to label the segmental outflow pattern followed by perfusion-fixation. Three radial wedges of tissue including SC from high-, low-, and non-flow areas of each eye based on tracer distribution were processed for SBF-SEM. GVs were counted and typed (Type I: no intracellular pore (I-pore), no basal opening, Type II: no I-pore, present basal opening, Type III: no basal opening, present I-pore, and Type IV: present I-pore and basal opening). 3D reconstruction was performed on a GV subset. A subset of GVs was randomly selected for 3D reconstruction to measure GV volume. GVs in eyes perfused at 7 mmHg were compared with a previous GV study in eyes perfused at 15 mmHg. A similar number of images were analyzed at 7 mmHg (9586 images) and 15 mmHg (9802 images). Statistical analyses were performed using R statistical computing package. There was a greater number of GVs at 15 mmHg (3302 GVs) compared to 7 mmHg (1312 GVs). Type IV GVs were more abundant in the high-flow than non-flow areas at both pressures (P≤0.01). GVs with I-pores were significantly larger than GVs without I-pores in all flow-type areas at both pressures (P≤0.01). GVs with I-pores were similar in volume at both pressures in all GVs and in high- and non-flow areas. However, GVs without I-pores were significantly larger in volume at elevated pressure (P≤0.01). SBF-SEM and 3D reconstruction allowed for accurate identification of GV types and size. Comparing both pressures, the volume of GVs with I-pores were similar, while the volume of GVs without I-pores were larger at elevated pressures. This may indicate a threshold size of GVs for pore formation. GVs with I-pores were significantly larger than GVs without I-pores in all flow-type areas at both pressures suggesting that larger size of GVs is a contributing factor for GV-associated I-pore formation. More Type IV GVs observed in the high-flow areas at both pressures suggest that Type VI GV formation may play a role in regulating segmental outflow and increasing this type of GV may increase the total high-flow area.","abstract_html":"Glaucoma is a disease characterized by elevated intra-ocular pressure and chronic, irreversible loss of vision. The precise mechanism by which outflow resistance is generated remains elusive. We investigated a unique structure called the giant vacuole (GV) in the inner wall endothelium of Schlemm’s canal (SC) that contribute to regulating outflow resistance. This study aimed to: 1) investigate the types and size of GVs in eyes perfused at 7 mmHg (physiological pressure in enucleated eyes) in the inner wall endothelium of SC using serial block-face scanning electron microscopy (SBF-SEM) and subsequent three-dimensional (3D) reconstruction of GVs; 2) to compare differences in the types and sizes of GVs in eyes perfused at 7 mmHg with published results in eyes perfused at 15 mm Hg (Swain et al, 2021). Two normal human donor eyes were perfused at 7 mmHg with fluorescent tracers to label the segmental outflow pattern followed by perfusion-fixation. Three radial wedges of tissue including SC from high-, low-, and non-flow areas of each eye based on tracer distribution were processed for SBF-SEM. GVs were counted and typed (Type I: no intracellular pore (I-pore), no basal opening, Type II: no I-pore, present basal opening, Type III: no basal opening, present I-pore, and Type IV: present I-pore and basal opening). 3D reconstruction was performed on a GV subset. A subset of GVs was randomly selected for 3D reconstruction to measure GV volume. GVs in eyes perfused at 7 mmHg were compared with a previous GV study in eyes perfused at 15 mmHg. A similar number of images were analyzed at 7 mmHg (9586 images) and 15 mmHg (9802 images). Statistical analyses were performed using R statistical computing package. There was a greater number of GVs at 15 mmHg (3302 GVs) compared to 7 mmHg (1312 GVs). Type IV GVs were more abundant in the high-flow than non-flow areas at both pressures (P≤0.01). GVs with I-pores were significantly larger than GVs without I-pores in all flow-type areas at both pressures (P≤0.01). GVs with I-pores were similar in volume at both pressures in all GVs and in high- and non-flow areas. However, GVs without I-pores were significantly larger in volume at elevated pressure (P≤0.01). SBF-SEM and 3D reconstruction allowed for accurate identification of GV types and size. Comparing both pressures, the volume of GVs with I-pores were similar, while the volume of GVs without I-pores were larger at elevated pressures. This may indicate a threshold size of GVs for pore formation. GVs with I-pores were significantly larger than GVs without I-pores in all flow-type areas at both pressures suggesting that larger size of GVs is a contributing factor for GV-associated I-pore formation. More Type IV GVs observed in the high-flow areas at both pressures suggest that Type VI GV formation may play a role in regulating segmental outflow and increasing this type of GV may increase the total high-flow area.","abstract_has_math":false,"creators":["Soares, Benjamin L."],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Medical Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Gong, Haiyan"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-18T19:48:56Z","subjects":["Medicine","Aqueous outflow","Giant vacuoles","Glaucoma","Schlemm's canal"],"languages":["en_US"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/45667","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/45667","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F45667","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gong, Haiyan"]},{"key":"dc:creator","label":"Author","values":["Soares, Benjamin L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-02-24T15:26:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-02-24T15:26:31Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-02-17T02:04:02Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medical Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Medicine","Aqueous outflow","Giant vacuoles","Glaucoma","Schlemm's canal"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/45667"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Glaucoma is a disease characterized by elevated intra-ocular pressure and chronic, irreversible loss of vision. The precise mechanism by which outflow resistance is generated remains elusive. We investigated a unique structure called the giant vacuole (GV) in the inner wall endothelium of Schlemm’s canal (SC) that contribute to regulating outflow resistance. This study aimed to: 1) investigate the types and size of GVs in eyes perfused at 7 mmHg (physiological pressure in enucleated eyes) in the inner wall endothelium of SC using serial block-face scanning electron microscopy (SBF-SEM) and subsequent three-dimensional (3D) reconstruction of GVs; 2) to compare differences in the types and sizes of GVs in eyes perfused at 7 mmHg with published results in eyes perfused at 15 mm Hg (Swain et al, 2021). Two normal human donor eyes were perfused at 7 mmHg with fluorescent tracers to label the segmental outflow pattern followed by perfusion-fixation. Three radial wedges of tissue including SC from high-, low-, and non-flow areas of each eye based on tracer distribution were processed for SBF-SEM. GVs were counted and typed (Type I: no intracellular pore (I-pore), no basal opening, Type II: no I-pore, present basal opening, Type III: no basal opening, present I-pore, and Type IV: present I-pore and basal opening). 3D reconstruction was performed on a GV subset. A subset of GVs was randomly selected for 3D reconstruction to measure GV volume. GVs in eyes perfused at 7 mmHg were compared with a previous GV study in eyes perfused at 15 mmHg. A similar number of images were analyzed at 7 mmHg (9586 images) and 15 mmHg (9802 images). Statistical analyses were performed using R statistical computing package. There was a greater number of GVs at 15 mmHg (3302 GVs) compared to 7 mmHg (1312 GVs). Type IV GVs were more abundant in the high-flow than non-flow areas at both pressures (P≤0.01). GVs with I-pores were significantly larger than GVs without I-pores in all flow-type areas at both pressures (P≤0.01). GVs with I-pores were similar in volume at both pressures in all GVs and in high- and non-flow areas. However, GVs without I-pores were significantly larger in volume at elevated pressure (P≤0.01). SBF-SEM and 3D reconstruction allowed for accurate identification of GV types and size. Comparing both pressures, the volume of GVs with I-pores were similar, while the volume of GVs without I-pores were larger at elevated pressures. This may indicate a threshold size of GVs for pore formation. GVs with I-pores were significantly larger than GVs without I-pores in all flow-type areas at both pressures suggesting that larger size of GVs is a contributing factor for GV-associated I-pore formation. More Type IV GVs observed in the high-flow areas at both pressures suggest that Type VI GV formation may play a role in regulating segmental outflow and increasing this type of GV may increase the total high-flow area."]},{"key":"dc:title","label":"Title","values":["Investigation of giant vacuoles in the inner wall endothelium of Schlemm's canal at physiologic pressure and comparison of the types and size of giant vacuoles in human eyes perfused at 7- and 15-mm Hg using serial block-face scanning electron microscopy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gong, Haiyan"],"dc:creator":["Soares, Benjamin L."],"dc:date.accessioned":["2023-02-24T15:26:31Z"],"dc:date.available":["2023-02-24T15:26:31Z"],"dc:date.issued":["2022"],"dc:date.updated":["2023-02-17T02:04:02Z"],"dc:description.abstract":["Glaucoma is a disease characterized by elevated intra-ocular pressure and chronic, irreversible loss of vision. The precise mechanism by which outflow resistance is generated remains elusive. We investigated a unique structure called the giant vacuole (GV) in the inner wall endothelium of Schlemm’s canal (SC) that contribute to regulating outflow resistance. This study aimed to: 1) investigate the types and size of GVs in eyes perfused at 7 mmHg (physiological pressure in enucleated eyes) in the inner wall endothelium of SC using serial block-face scanning electron microscopy (SBF-SEM) and subsequent three-dimensional (3D) reconstruction of GVs; 2) to compare differences in the types and sizes of GVs in eyes perfused at 7 mmHg with published results in eyes perfused at 15 mm Hg (Swain et al, 2021). Two normal human donor eyes were perfused at 7 mmHg with fluorescent tracers to label the segmental outflow pattern followed by perfusion-fixation. Three radial wedges of tissue including SC from high-, low-, and non-flow areas of each eye based on tracer distribution were processed for SBF-SEM. GVs were counted and typed (Type I: no intracellular pore (I-pore), no basal opening, Type II: no I-pore, present basal opening, Type III: no basal opening, present I-pore, and Type IV: present I-pore and basal opening). 3D reconstruction was performed on a GV subset. A subset of GVs was randomly selected for 3D reconstruction to measure GV volume. GVs in eyes perfused at 7 mmHg were compared with a previous GV study in eyes perfused at 15 mmHg. A similar number of images were analyzed at 7 mmHg (9586 images) and 15 mmHg (9802 images). Statistical analyses were performed using R statistical computing package. There was a greater number of GVs at 15 mmHg (3302 GVs) compared to 7 mmHg (1312 GVs). Type IV GVs were more abundant in the high-flow than non-flow areas at both pressures (P≤0.01). GVs with I-pores were significantly larger than GVs without I-pores in all flow-type areas at both pressures (P≤0.01). GVs with I-pores were similar in volume at both pressures in all GVs and in high- and non-flow areas. However, GVs without I-pores were significantly larger in volume at elevated pressure (P≤0.01). SBF-SEM and 3D reconstruction allowed for accurate identification of GV types and size. Comparing both pressures, the volume of GVs with I-pores were similar, while the volume of GVs without I-pores were larger at elevated pressures. This may indicate a threshold size of GVs for pore formation. GVs with I-pores were significantly larger than GVs without I-pores in all flow-type areas at both pressures suggesting that larger size of GVs is a contributing factor for GV-associated I-pore formation. More Type IV GVs observed in the high-flow areas at both pressures suggest that Type VI GV formation may play a role in regulating segmental outflow and increasing this type of GV may increase the total high-flow area."],"dc:identifier.uri":["https://hdl.handle.net/2144/45667"],"dc:language.iso":["en_US"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Medicine","Aqueous outflow","Giant vacuoles","Glaucoma","Schlemm's canal"],"dc:title":["Investigation of giant vacuoles in the inner wall endothelium of Schlemm's canal at physiologic pressure and comparison of the types and size of giant vacuoles in human eyes perfused at 7- and 15-mm Hg using serial block-face scanning electron microscopy"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Medical Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:48:56Z"}