{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/46353"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/46353","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Retrospective review of pre surgical variables associated with marginal bone loss measured at 2nd stage abutment surgery for endosseous dental implants","abstract":"AIM: To measure marginal bone loss around endosseous dental implants at 2nd stage abutment surgery and retrospectively evaluate the association of pre-surgical variables with bone findings. MATERIALS AND METHODS: Two implant systems were included in the study design. Straumann Bone Level Tapered SLActive and Nobel Biocare Replace Conical Connection. Implants were placed by the same resident from the Periodontics department. Clinical measurements of bone level were recorded at the time of placement and then again at 2nd stage surgery at four different points (mesial, lingual, buccal, distal). RESULTS: Five implants were evaluated in the study. Bone loss averages ranged from 0-1.0mm. Nobel implants had an average loss of .75mm and Straumann implants had an average loss of .67mm. CONCLUSION: Many variables contribute to marginal bone loss around endosseous dental implants at 2nd stage abutment surgery. The current research was designed to understand the relationship between these variables and early marginal bone loss. All implant samples included here were defined as control because of ≤1.0mm bone loss per IRB protocol.","abstract_html":"AIM: To measure marginal bone loss around endosseous dental implants at 2nd stage abutment surgery and retrospectively evaluate the association of pre-surgical variables with bone findings. MATERIALS AND METHODS: Two implant systems were included in the study design. Straumann Bone Level Tapered SLActive and Nobel Biocare Replace Conical Connection. Implants were placed by the same resident from the Periodontics department. Clinical measurements of bone level were recorded at the time of placement and then again at 2nd stage surgery at four different points (mesial, lingual, buccal, distal). RESULTS: Five implants were evaluated in the study. Bone loss averages ranged from 0-1.0mm. Nobel implants had an average loss of .75mm and Straumann implants had an average loss of .67mm. CONCLUSION: Many variables contribute to marginal bone loss around endosseous dental implants at 2nd stage abutment surgery. The current research was designed to understand the relationship between these variables and early marginal bone loss. All implant samples included here were defined as control because of ≤1.0mm bone loss per IRB protocol.","abstract_has_math":false,"creators":["Mancuso, Vanessa Lynn"],"institution":"Boston University","degree_name":"Master of Science in Design","degree_level":"masters","degree_discipline":"Periodontology","degree_department":null,"school":null,"contributors":[],"advisors":["Dibart, Serge","Price, Albert M."],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-18T20:17:14Z","subjects":["Dentistry","Implants","Marginal bone loss","Osseointegration"],"languages":["en_US"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/46353","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/46353","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F46353","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dibart, Serge","Price, Albert M."]},{"key":"dc:creator","label":"Author","values":["Mancuso, Vanessa Lynn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-06-22T15:19:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-06-22T15:19:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2023-06-15T16:10:49Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Periodontology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Design"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry","Implants","Marginal bone loss","Osseointegration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/46353"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["AIM: To measure marginal bone loss around endosseous dental implants at 2nd stage abutment surgery and retrospectively evaluate the association of pre-surgical variables with bone findings. MATERIALS AND METHODS: Two implant systems were included in the study design. Straumann Bone Level Tapered SLActive and Nobel Biocare Replace Conical Connection. Implants were placed by the same resident from the Periodontics department. Clinical measurements of bone level were recorded at the time of placement and then again at 2nd stage surgery at four different points (mesial, lingual, buccal, distal). RESULTS: Five implants were evaluated in the study. Bone loss averages ranged from 0-1.0mm. Nobel implants had an average loss of .75mm and Straumann implants had an average loss of .67mm. CONCLUSION: Many variables contribute to marginal bone loss around endosseous dental implants at 2nd stage abutment surgery. The current research was designed to understand the relationship between these variables and early marginal bone loss. All implant samples included here were defined as control because of ≤1.0mm bone loss per IRB protocol."]},{"key":"dc:title","label":"Title","values":["Retrospective review of pre surgical variables associated with marginal bone loss measured at 2nd stage abutment surgery for endosseous dental implants"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dibart, Serge","Price, Albert M."],"dc:creator":["Mancuso, Vanessa Lynn"],"dc:date.accessioned":["2023-06-22T15:19:52Z"],"dc:date.available":["2023-06-22T15:19:52Z"],"dc:date.issued":["2023"],"dc:date.updated":["2023-06-15T16:10:49Z"],"dc:description.abstract":["AIM: To measure marginal bone loss around endosseous dental implants at 2nd stage abutment surgery and retrospectively evaluate the association of pre-surgical variables with bone findings. MATERIALS AND METHODS: Two implant systems were included in the study design. Straumann Bone Level Tapered SLActive and Nobel Biocare Replace Conical Connection. Implants were placed by the same resident from the Periodontics department. Clinical measurements of bone level were recorded at the time of placement and then again at 2nd stage surgery at four different points (mesial, lingual, buccal, distal). RESULTS: Five implants were evaluated in the study. Bone loss averages ranged from 0-1.0mm. Nobel implants had an average loss of .75mm and Straumann implants had an average loss of .67mm. CONCLUSION: Many variables contribute to marginal bone loss around endosseous dental implants at 2nd stage abutment surgery. The current research was designed to understand the relationship between these variables and early marginal bone loss. All implant samples included here were defined as control because of ≤1.0mm bone loss per IRB protocol."],"dc:identifier.uri":["https://hdl.handle.net/2144/46353"],"dc:language.iso":["en_US"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Dentistry","Implants","Marginal bone loss","Osseointegration"],"dc:title":["Retrospective review of pre surgical variables associated with marginal bone loss measured at 2nd stage abutment surgery for endosseous dental implants"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Periodontology"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Design"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T20:17:14Z"}