{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/48869"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/48869","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"A magnetically-controlled soft robotic glove for hand rehabilitation","abstract":"Rehabilitation interventions for motor practice are necessary for patients with impaired hand function to regain strength and range of motion. Clinical rehabilitative therapies are found to be costly and insufficient in terms of frequency due to their limited accessibility. Recently, advancements in robotic devices have improved accessibility and have been useful in facilitating repetitive tasks. This work presents a magnetically-controlled soft robotic glove with a quick and tunable stiffening mechanism that is also safe for the patients and conveniently portable. The magnetic control is achieved by employing a unique array of EPMs within a medium of MRF-immersed fibers. This array of EPMs enables customized rehabilitation depending on the patient’s pathology. The glove is designed to have a discontinuous structure that mimics the anatomy of the fingers, which comprises joints and linkages. The glove is tested for flexion, extension, abduction, and pinch grip exercises, and the impact of the stiffness change provided by the glove is validated through an EMG sensor. This design offers a portable, safe, easy-to-control, and customizable wearable rehabilitative technology for patients with hand impairment.","abstract_html":"Rehabilitation interventions for motor practice are necessary for patients with impaired hand function to regain strength and range of motion. Clinical rehabilitative therapies are found to be costly and insufficient in terms of frequency due to their limited accessibility. Recently, advancements in robotic devices have improved accessibility and have been useful in facilitating repetitive tasks. This work presents a magnetically-controlled soft robotic glove with a quick and tunable stiffening mechanism that is also safe for the patients and conveniently portable. The magnetic control is achieved by employing a unique array of EPMs within a medium of MRF-immersed fibers. This array of EPMs enables customized rehabilitation depending on the patient’s pathology. The glove is designed to have a discontinuous structure that mimics the anatomy of the fingers, which comprises joints and linkages. The glove is tested for flexion, extension, abduction, and pinch grip exercises, and the impact of the stiffness change provided by the glove is validated through an EMG sensor. This design offers a portable, safe, easy-to-control, and customizable wearable rehabilitative technology for patients with hand impairment.","abstract_has_math":false,"creators":["Albayrak, Meliha Deniz"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Ranzani, Tommaso"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T02:41:58Z","subjects":["Mechanical engineering","Rehabilitation","Soft robotics"],"languages":["en_US"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[{"key":"dc:identifier.orcid","label":"ORCID","values":["0009-0008-7097-8983"],"render_values":[{"text":"0009-0008-7097-8983","href":"https://orcid.org/0009-0008-7097-8983","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/2144/48869","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/48869","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F48869","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ranzani, Tommaso"]},{"key":"dc:creator","label":"Author","values":["Albayrak, Meliha Deniz"]},{"key":"dc:identifier.orcid","label":"ORCID","values":["0009-0008-7097-8983"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-05-28T13:51:30Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2026-05-23T00:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-05-24T01:02:32Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical engineering","Rehabilitation","Soft robotics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/48869"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Rehabilitation interventions for motor practice are necessary for patients with impaired hand function to regain strength and range of motion. Clinical rehabilitative therapies are found to be costly and insufficient in terms of frequency due to their limited accessibility. Recently, advancements in robotic devices have improved accessibility and have been useful in facilitating repetitive tasks. This work presents a magnetically-controlled soft robotic glove with a quick and tunable stiffening mechanism that is also safe for the patients and conveniently portable. The magnetic control is achieved by employing a unique array of EPMs within a medium of MRF-immersed fibers. This array of EPMs enables customized rehabilitation depending on the patient’s pathology. The glove is designed to have a discontinuous structure that mimics the anatomy of the fingers, which comprises joints and linkages. The glove is tested for flexion, extension, abduction, and pinch grip exercises, and the impact of the stiffness change provided by the glove is validated through an EMG sensor. This design offers a portable, safe, easy-to-control, and customizable wearable rehabilitative technology for patients with hand impairment."]},{"key":"dc:title","label":"Title","values":["A magnetically-controlled soft robotic glove for hand rehabilitation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ranzani, Tommaso"],"dc:creator":["Albayrak, Meliha Deniz"],"dc:date.accessioned":["2024-05-28T13:51:30Z"],"dc:date.embargo":["2026-05-23T00:00:00Z"],"dc:date.issued":["2024"],"dc:date.updated":["2024-05-24T01:02:32Z"],"dc:description.abstract":["Rehabilitation interventions for motor practice are necessary for patients with impaired hand function to regain strength and range of motion. Clinical rehabilitative therapies are found to be costly and insufficient in terms of frequency due to their limited accessibility. Recently, advancements in robotic devices have improved accessibility and have been useful in facilitating repetitive tasks. This work presents a magnetically-controlled soft robotic glove with a quick and tunable stiffening mechanism that is also safe for the patients and conveniently portable. The magnetic control is achieved by employing a unique array of EPMs within a medium of MRF-immersed fibers. This array of EPMs enables customized rehabilitation depending on the patient’s pathology. The glove is designed to have a discontinuous structure that mimics the anatomy of the fingers, which comprises joints and linkages. The glove is tested for flexion, extension, abduction, and pinch grip exercises, and the impact of the stiffness change provided by the glove is validated through an EMG sensor. This design offers a portable, safe, easy-to-control, and customizable wearable rehabilitative technology for patients with hand impairment."],"dc:identifier.orcid":["0009-0008-7097-8983"],"dc:identifier.uri":["https://hdl.handle.net/2144/48869"],"dc:language.iso":["en_US"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Mechanical engineering","Rehabilitation","Soft robotics"],"dc:title":["A magnetically-controlled soft robotic glove for hand rehabilitation"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-19T02:41:58Z"}