{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/49101"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/49101","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Robotic-assisted surgery, is it more accurate?","abstract":"Dental implant guidance systems promise precise placement, but postoperative assessment with CBCT scans poses radiation risks. This study utilizes an optical scanning method to evaluate implant placement position and assess the accuracy of robotic assistance using the Neocis Yomi system. METHODS: In a longitudinal study at Boston University, Robotic-assisted dental implant Placement was evaluated. The test population excluded fully edentulous patients. The current cohort focused on eight patients: four were fully guided, and four were partially guided. Optical impressions were obtained with a CEREC Omnicam scanner and indexed using ELOS-accurate Scan Bodies. The preop virtual placement plan was merged with the actual post-op implant placement and then analyzed with Geomagic Control X software to measure deviations between planned and executed positions. RESULTS: In the four Fully guided patients, the deviation of the Implant at the platform level, midpoint, and apex was 1.3133mm, 1.4425mm, and 1.4355mm, respectively. In the four partially guided patients, the implant deviation at the platform, midpoint, and apex was 1.691mm, 1.0291mm, and 2.2226mm. CONCLUSION: Despite the study limitations, robotically assisted implant surgery demonstrates accuracy comparable to traditional guidance systems. The use of Intraoral optical scan bodies provides a radiation-free evaluation of the as planned vs. executed dental implant placement. This method should be adopted for future research.","abstract_html":"Dental implant guidance systems promise precise placement, but postoperative assessment with CBCT scans poses radiation risks. This study utilizes an optical scanning method to evaluate implant placement position and assess the accuracy of robotic assistance using the Neocis Yomi system. METHODS: In a longitudinal study at Boston University, Robotic-assisted dental implant Placement was evaluated. The test population excluded fully edentulous patients. The current cohort focused on eight patients: four were fully guided, and four were partially guided. Optical impressions were obtained with a CEREC Omnicam scanner and indexed using ELOS-accurate Scan Bodies. The preop virtual placement plan was merged with the actual post-op implant placement and then analyzed with Geomagic Control X software to measure deviations between planned and executed positions. RESULTS: In the four Fully guided patients, the deviation of the Implant at the platform level, midpoint, and apex was 1.3133mm, 1.4425mm, and 1.4355mm, respectively. In the four partially guided patients, the implant deviation at the platform, midpoint, and apex was 1.691mm, 1.0291mm, and 2.2226mm. CONCLUSION: Despite the study limitations, robotically assisted implant surgery demonstrates accuracy comparable to traditional guidance systems. The use of Intraoral optical scan bodies provides a radiation-free evaluation of the as planned vs. executed dental implant placement. This method should be adopted for future research.","abstract_has_math":false,"creators":["Alani, Abdulla Mohammed"],"institution":"Boston University","degree_name":"Master of Science in Design","degree_level":"masters","degree_discipline":"Periodontology","degree_department":null,"school":null,"contributors":[],"advisors":["Price, Albert","Kernitsk, Jeremy"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-18T19:48:01Z","subjects":["Dentistry","Accuracy","Dental implants","Guided","Robotic"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/49101","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/49101","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F49101","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Price, Albert","Kernitsk, Jeremy"]},{"key":"dc:creator","label":"Author","values":["Alani, Abdulla Mohammed"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-05T13:54:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-05T13:54:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2024-08-02T16:11:16Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Periodontology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Design"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry","Accuracy","Dental implants","Guided","Robotic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/49101"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Dental implant guidance systems promise precise placement, but postoperative assessment with CBCT scans poses radiation risks. This study utilizes an optical scanning method to evaluate implant placement position and assess the accuracy of robotic assistance using the Neocis Yomi system. METHODS: In a longitudinal study at Boston University, Robotic-assisted dental implant Placement was evaluated. The test population excluded fully edentulous patients. The current cohort focused on eight patients: four were fully guided, and four were partially guided. Optical impressions were obtained with a CEREC Omnicam scanner and indexed using ELOS-accurate Scan Bodies. The preop virtual placement plan was merged with the actual post-op implant placement and then analyzed with Geomagic Control X software to measure deviations between planned and executed positions. RESULTS: In the four Fully guided patients, the deviation of the Implant at the platform level, midpoint, and apex was 1.3133mm, 1.4425mm, and 1.4355mm, respectively. In the four partially guided patients, the implant deviation at the platform, midpoint, and apex was 1.691mm, 1.0291mm, and 2.2226mm. CONCLUSION: Despite the study limitations, robotically assisted implant surgery demonstrates accuracy comparable to traditional guidance systems. The use of Intraoral optical scan bodies provides a radiation-free evaluation of the as planned vs. executed dental implant placement. This method should be adopted for future research."]},{"key":"dc:title","label":"Title","values":["Robotic-assisted surgery, is it more accurate?"]}]}],"canonical_facts":{"dc:contributor.advisor":["Price, Albert","Kernitsk, Jeremy"],"dc:creator":["Alani, Abdulla Mohammed"],"dc:date.accessioned":["2024-08-05T13:54:10Z"],"dc:date.available":["2024-08-05T13:54:10Z"],"dc:date.issued":["2024"],"dc:date.updated":["2024-08-02T16:11:16Z"],"dc:description.abstract":["Dental implant guidance systems promise precise placement, but postoperative assessment with CBCT scans poses radiation risks. This study utilizes an optical scanning method to evaluate implant placement position and assess the accuracy of robotic assistance using the Neocis Yomi system. METHODS: In a longitudinal study at Boston University, Robotic-assisted dental implant Placement was evaluated. The test population excluded fully edentulous patients. The current cohort focused on eight patients: four were fully guided, and four were partially guided. Optical impressions were obtained with a CEREC Omnicam scanner and indexed using ELOS-accurate Scan Bodies. The preop virtual placement plan was merged with the actual post-op implant placement and then analyzed with Geomagic Control X software to measure deviations between planned and executed positions. RESULTS: In the four Fully guided patients, the deviation of the Implant at the platform level, midpoint, and apex was 1.3133mm, 1.4425mm, and 1.4355mm, respectively. In the four partially guided patients, the implant deviation at the platform, midpoint, and apex was 1.691mm, 1.0291mm, and 2.2226mm. CONCLUSION: Despite the study limitations, robotically assisted implant surgery demonstrates accuracy comparable to traditional guidance systems. The use of Intraoral optical scan bodies provides a radiation-free evaluation of the as planned vs. executed dental implant placement. This method should be adopted for future research."],"dc:identifier.uri":["https://hdl.handle.net/2144/49101"],"dc:language.iso":["en_US"],"dc:subject":["Dentistry","Accuracy","Dental implants","Guided","Robotic"],"dc:title":["Robotic-assisted surgery, is it more accurate?"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Periodontology"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Design"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:48:01Z"}