{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/51764"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/51764","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Effects of chemical blood enhancement methods on downstream biological testing","abstract":"A common body fluid recovered from crime scenes is blood. The identification of bloodstains is important to forensic investigations as blood contains deoxyribonucleic acid (DNA), which can be used to generate genetic profiles for inclusion and exclusion comparisons of persons involved in a criminal investigation. Downstream testing of blood is also useful for forensic practitioners as it can identify human blood, which can be used for crime scene reconstructions, as well as for establishing potential linkages between the evidence, suspect, and/or victim. However, blood identification at a crime scene may not always be straightforward as the bloodstains remaining may consist of trace amounts or be non-visible (latent) if the suspect attempted to clean the area. As a result, forensic investigators may have to use chemical enhancement methods to locate potential bloodstains or to enhance bloodstains otherwise not visible. This study explored the potential effects chemical blood enhancements may have on downstream biological testing. Results concluded the Leuco Crystal Violet (LCV) chemical blood enhancement increased the number of false negative and inconclusive results when bloodstains were subsequently tested with the Kastle-Meyer and ortho-tolidine presumptive catalytic color tests as well as the ABAcard® HemaTrace® confirmatory immunoassay card. This was true for stains on both porous and non-porous substrates regardless of bloodstain size or time between enhancement application and subsequent testing. Results further showed the Grodsky luminol chemical blood enhancement reduced the number of positive results of diluted bloodstains when tested with the Kastle-Meyer presumptive blood test and correlated with a reduction in accurate detection of bloodstains when tested at 2 weeks or 2 months post enhancement with Ortho-Tolidine, Kastle-Meyer, and ABAcard® HemaTrace® on non-porous substrates. The Weber luminol chemical blood enhancement had the least effect on downstream biological tests, however, a reduction in positive detections were observed at 2 months post enhancement for the Kastle-Meyer and ABAcard® HemaTrace® blood tests on porous substrates.","abstract_html":"A common body fluid recovered from crime scenes is blood. The identification of bloodstains is important to forensic investigations as blood contains deoxyribonucleic acid (DNA), which can be used to generate genetic profiles for inclusion and exclusion comparisons of persons involved in a criminal investigation. Downstream testing of blood is also useful for forensic practitioners as it can identify human blood, which can be used for crime scene reconstructions, as well as for establishing potential linkages between the evidence, suspect, and/or victim. However, blood identification at a crime scene may not always be straightforward as the bloodstains remaining may consist of trace amounts or be non-visible (latent) if the suspect attempted to clean the area. As a result, forensic investigators may have to use chemical enhancement methods to locate potential bloodstains or to enhance bloodstains otherwise not visible. This study explored the potential effects chemical blood enhancements may have on downstream biological testing. Results concluded the Leuco Crystal Violet (LCV) chemical blood enhancement increased the number of false negative and inconclusive results when bloodstains were subsequently tested with the Kastle-Meyer and ortho-tolidine presumptive catalytic color tests as well as the ABAcard® HemaTrace® confirmatory immunoassay card. This was true for stains on both porous and non-porous substrates regardless of bloodstain size or time between enhancement application and subsequent testing. Results further showed the Grodsky luminol chemical blood enhancement reduced the number of positive results of diluted bloodstains when tested with the Kastle-Meyer presumptive blood test and correlated with a reduction in accurate detection of bloodstains when tested at 2 weeks or 2 months post enhancement with Ortho-Tolidine, Kastle-Meyer, and ABAcard® HemaTrace® on non-porous substrates. The Weber luminol chemical blood enhancement had the least effect on downstream biological tests, however, a reduction in positive detections were observed at 2 months post enhancement for the Kastle-Meyer and ABAcard® HemaTrace® blood tests on porous substrates.","abstract_has_math":false,"creators":["Columbus, Madison Margaret"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Forensic Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Brodeur, Amy N."],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-18T19:50:59Z","subjects":["Criminology","Blood","Chemical blood enhancement","Confirmatory blood tests","Non-porous","Porous","Presumptive blood tests"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/51764","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/51764","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F51764","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Brodeur, Amy N."]},{"key":"dc:creator","label":"Author","values":["Columbus, Madison Margaret"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-11-10T18:06:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-11-10T18:06:54Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2025-11-10T17:01:33Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Forensic Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Criminology","Blood","Chemical blood enhancement","Confirmatory blood tests","Non-porous","Porous","Presumptive blood tests"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/51764"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["2024"]},{"key":"dc:description.abstract","label":"Abstract","values":["A common body fluid recovered from crime scenes is blood. The identification of bloodstains is important to forensic investigations as blood contains deoxyribonucleic acid (DNA), which can be used to generate genetic profiles for inclusion and exclusion comparisons of persons involved in a criminal investigation. Downstream testing of blood is also useful for forensic practitioners as it can identify human blood, which can be used for crime scene reconstructions, as well as for establishing potential linkages between the evidence, suspect, and/or victim. However, blood identification at a crime scene may not always be straightforward as the bloodstains remaining may consist of trace amounts or be non-visible (latent) if the suspect attempted to clean the area. As a result, forensic investigators may have to use chemical enhancement methods to locate potential bloodstains or to enhance bloodstains otherwise not visible. This study explored the potential effects chemical blood enhancements may have on downstream biological testing. Results concluded the Leuco Crystal Violet (LCV) chemical blood enhancement increased the number of false negative and inconclusive results when bloodstains were subsequently tested with the Kastle-Meyer and ortho-tolidine presumptive catalytic color tests as well as the ABAcard® HemaTrace® confirmatory immunoassay card. This was true for stains on both porous and non-porous substrates regardless of bloodstain size or time between enhancement application and subsequent testing. Results further showed the Grodsky luminol chemical blood enhancement reduced the number of positive results of diluted bloodstains when tested with the Kastle-Meyer presumptive blood test and correlated with a reduction in accurate detection of bloodstains when tested at 2 weeks or 2 months post enhancement with Ortho-Tolidine, Kastle-Meyer, and ABAcard® HemaTrace® on non-porous substrates. The Weber luminol chemical blood enhancement had the least effect on downstream biological tests, however, a reduction in positive detections were observed at 2 months post enhancement for the Kastle-Meyer and ABAcard® HemaTrace® blood tests on porous substrates."]},{"key":"dc:title","label":"Title","values":["Effects of chemical blood enhancement methods on downstream biological testing"]}]}],"canonical_facts":{"dc:contributor.advisor":["Brodeur, Amy N."],"dc:creator":["Columbus, Madison Margaret"],"dc:date.accessioned":["2025-11-10T18:06:54Z"],"dc:date.available":["2025-11-10T18:06:54Z"],"dc:date.issued":["2024"],"dc:date.updated":["2025-11-10T17:01:33Z"],"dc:description":["2024"],"dc:description.abstract":["A common body fluid recovered from crime scenes is blood. The identification of bloodstains is important to forensic investigations as blood contains deoxyribonucleic acid (DNA), which can be used to generate genetic profiles for inclusion and exclusion comparisons of persons involved in a criminal investigation. Downstream testing of blood is also useful for forensic practitioners as it can identify human blood, which can be used for crime scene reconstructions, as well as for establishing potential linkages between the evidence, suspect, and/or victim. However, blood identification at a crime scene may not always be straightforward as the bloodstains remaining may consist of trace amounts or be non-visible (latent) if the suspect attempted to clean the area. As a result, forensic investigators may have to use chemical enhancement methods to locate potential bloodstains or to enhance bloodstains otherwise not visible. This study explored the potential effects chemical blood enhancements may have on downstream biological testing. Results concluded the Leuco Crystal Violet (LCV) chemical blood enhancement increased the number of false negative and inconclusive results when bloodstains were subsequently tested with the Kastle-Meyer and ortho-tolidine presumptive catalytic color tests as well as the ABAcard® HemaTrace® confirmatory immunoassay card. This was true for stains on both porous and non-porous substrates regardless of bloodstain size or time between enhancement application and subsequent testing. Results further showed the Grodsky luminol chemical blood enhancement reduced the number of positive results of diluted bloodstains when tested with the Kastle-Meyer presumptive blood test and correlated with a reduction in accurate detection of bloodstains when tested at 2 weeks or 2 months post enhancement with Ortho-Tolidine, Kastle-Meyer, and ABAcard® HemaTrace® on non-porous substrates. The Weber luminol chemical blood enhancement had the least effect on downstream biological tests, however, a reduction in positive detections were observed at 2 months post enhancement for the Kastle-Meyer and ABAcard® HemaTrace® blood tests on porous substrates."],"dc:identifier.uri":["https://hdl.handle.net/2144/51764"],"dc:language.iso":["en_US"],"dc:subject":["Criminology","Blood","Chemical blood enhancement","Confirmatory blood tests","Non-porous","Porous","Presumptive blood tests"],"dc:title":["Effects of chemical blood enhancement methods on downstream biological testing"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Forensic Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:50:59Z"}