{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/52135"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/52135","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Droplet microfluidic platform automation with multi-modal sensing integration and closed-loop feedback","abstract":"Droplet microfluidics provides a platform for testing synthetic biology constructs. Droplet microfluidics can increase screening throughput by compartmentalizing samples into thousands of nanoliter-sized bioreactors per second, thereby eliminating the synthetic biology testing bottleneck. Despite recent advances in high-throughput screening utilizing droplet microfluidics, device design and characterization for specific applications remain resource and time-intensive. To address these challenges, we present the development of an automated droplet microfluidic platform that combines rapid device prototyping, custom multi-modal sensing, and closed-loop control for high-throughput biological and chemical analysis. The work bridges the gap between traditional, expert-driven microfluidic operation and fully autonomous systems capable of real-time monitoring and regulation. This research establishes a foundation for scalable, miniaturized, and programmable droplet microfluidics. First, the co-design and characterization of impedance and luminescence sensors was integrated with micromilled polycarbonate microfluidic devices. Conductive-ink electrodes were optimized for droplet impedance detection. Additionally, a photodetector was characterized for real-time luminescence sensing of bioluminescence reactions in droplets. Together, these results defined the electronic and microfluidic parameters necessary for accurate droplet sensing at nanoliter scales. Building on this sensing foundation, we designed and fabricated a modular droplet microfluidic platform to generate, manipulate, and analyze droplets with integrated multi-modal sensing. The platform achieved precise control of droplet size and throughput through feedback-driven flow regulation and demonstrated compatibility with high-speed camera imaging, impedance, luminescence, and fluorescence readouts. Finally, we present the Droplet Microfluidic Automation Machine (DropMAM), a unified hardware–software framework that automates droplet microfluidic operation through integrated sensing and closed-loop control. DropMAM automates device operation, characterization, and data analysis using real-time, high-speed camera, impedance, luminescence, or fluorescence measurements to adjust flow rates and pressure dynamically. By implementing adaptive feedback, the system maintains user-defined droplet properties such as size, throughput, and injection volume, transforming microfluidic experimentation into a reproducible and self-regulating process. Overall, this work establishes a scalable framework for integrating electronic sensing and feedback automation into droplet microfluidics. By combining rapid microfabrication, high-speed electronic characterization, and real-time software control, this platform enables the autonomous execution of complex droplet workflows with high precision and throughput.","abstract_html":"Droplet microfluidics provides a platform for testing synthetic biology constructs. Droplet microfluidics can increase screening throughput by compartmentalizing samples into thousands of nanoliter-sized bioreactors per second, thereby eliminating the synthetic biology testing bottleneck. Despite recent advances in high-throughput screening utilizing droplet microfluidics, device design and characterization for specific applications remain resource and time-intensive. To address these challenges, we present the development of an automated droplet microfluidic platform that combines rapid device prototyping, custom multi-modal sensing, and closed-loop control for high-throughput biological and chemical analysis. The work bridges the gap between traditional, expert-driven microfluidic operation and fully autonomous systems capable of real-time monitoring and regulation. This research establishes a foundation for scalable, miniaturized, and programmable droplet microfluidics. First, the co-design and characterization of impedance and luminescence sensors was integrated with micromilled polycarbonate microfluidic devices. Conductive-ink electrodes were optimized for droplet impedance detection. Additionally, a photodetector was characterized for real-time luminescence sensing of bioluminescence reactions in droplets. Together, these results defined the electronic and microfluidic parameters necessary for accurate droplet sensing at nanoliter scales. Building on this sensing foundation, we designed and fabricated a modular droplet microfluidic platform to generate, manipulate, and analyze droplets with integrated multi-modal sensing. The platform achieved precise control of droplet size and throughput through feedback-driven flow regulation and demonstrated compatibility with high-speed camera imaging, impedance, luminescence, and fluorescence readouts. Finally, we present the Droplet Microfluidic Automation Machine (DropMAM), a unified hardware–software framework that automates droplet microfluidic operation through integrated sensing and closed-loop control. DropMAM automates device operation, characterization, and data analysis using real-time, high-speed camera, impedance, luminescence, or fluorescence measurements to adjust flow rates and pressure dynamically. By implementing adaptive feedback, the system maintains user-defined droplet properties such as size, throughput, and injection volume, transforming microfluidic experimentation into a reproducible and self-regulating process. Overall, this work establishes a scalable framework for integrating electronic sensing and feedback automation into droplet microfluidics. By combining rapid microfabrication, high-speed electronic characterization, and real-time software control, this platform enables the autonomous execution of complex droplet workflows with high precision and throughput.","abstract_has_math":false,"creators":["Arguijo Mendoza, Diana"],"institution":"Boston University","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Densmore, Douglas M.","Yazicigil, Rabia Tugce"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T02:42:12Z","subjects":["Biomedical engineering","Automation","Droplet microfluidics","Error correction","Impedance sensing","Luminescence sensing","Multi-modal sensing"],"languages":["en_US"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[{"key":"dc:identifier.orcid","label":"ORCID","values":["0000-0002-3781-0328"],"render_values":[{"text":"0000-0002-3781-0328","href":"https://orcid.org/0000-0002-3781-0328","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/2144/52135","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/52135","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F52135","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Densmore, Douglas M.","Yazicigil, Rabia Tugce"]},{"key":"dc:creator","label":"Author","values":["Arguijo Mendoza, Diana"]},{"key":"dc:identifier.orcid","label":"ORCID","values":["0000-0002-3781-0328"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-02-02T16:20:08Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2028-01-29T00:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-01-29T23:03:53Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical engineering","Automation","Droplet microfluidics","Error correction","Impedance sensing","Luminescence sensing","Multi-modal sensing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/52135"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["2026"]},{"key":"dc:description.abstract","label":"Abstract","values":["Droplet microfluidics provides a platform for testing synthetic biology constructs. Droplet microfluidics can increase screening throughput by compartmentalizing samples into thousands of nanoliter-sized bioreactors per second, thereby eliminating the synthetic biology testing bottleneck. Despite recent advances in high-throughput screening utilizing droplet microfluidics, device design and characterization for specific applications remain resource and time-intensive. To address these challenges, we present the development of an automated droplet microfluidic platform that combines rapid device prototyping, custom multi-modal sensing, and closed-loop control for high-throughput biological and chemical analysis. The work bridges the gap between traditional, expert-driven microfluidic operation and fully autonomous systems capable of real-time monitoring and regulation. This research establishes a foundation for scalable, miniaturized, and programmable droplet microfluidics. First, the co-design and characterization of impedance and luminescence sensors was integrated with micromilled polycarbonate microfluidic devices. Conductive-ink electrodes were optimized for droplet impedance detection. Additionally, a photodetector was characterized for real-time luminescence sensing of bioluminescence reactions in droplets. Together, these results defined the electronic and microfluidic parameters necessary for accurate droplet sensing at nanoliter scales. Building on this sensing foundation, we designed and fabricated a modular droplet microfluidic platform to generate, manipulate, and analyze droplets with integrated multi-modal sensing. The platform achieved precise control of droplet size and throughput through feedback-driven flow regulation and demonstrated compatibility with high-speed camera imaging, impedance, luminescence, and fluorescence readouts. Finally, we present the Droplet Microfluidic Automation Machine (DropMAM), a unified hardware–software framework that automates droplet microfluidic operation through integrated sensing and closed-loop control. DropMAM automates device operation, characterization, and data analysis using real-time, high-speed camera, impedance, luminescence, or fluorescence measurements to adjust flow rates and pressure dynamically. By implementing adaptive feedback, the system maintains user-defined droplet properties such as size, throughput, and injection volume, transforming microfluidic experimentation into a reproducible and self-regulating process. Overall, this work establishes a scalable framework for integrating electronic sensing and feedback automation into droplet microfluidics. By combining rapid microfabrication, high-speed electronic characterization, and real-time software control, this platform enables the autonomous execution of complex droplet workflows with high precision and throughput."]},{"key":"dc:title","label":"Title","values":["Droplet microfluidic platform automation with multi-modal sensing integration and closed-loop feedback"]}]}],"canonical_facts":{"dc:contributor.advisor":["Densmore, Douglas M.","Yazicigil, Rabia Tugce"],"dc:creator":["Arguijo Mendoza, Diana"],"dc:date.accessioned":["2026-02-02T16:20:08Z"],"dc:date.embargo":["2028-01-29T00:00:00Z"],"dc:date.issued":["2026"],"dc:date.updated":["2026-01-29T23:03:53Z"],"dc:description":["2026"],"dc:description.abstract":["Droplet microfluidics provides a platform for testing synthetic biology constructs. Droplet microfluidics can increase screening throughput by compartmentalizing samples into thousands of nanoliter-sized bioreactors per second, thereby eliminating the synthetic biology testing bottleneck. Despite recent advances in high-throughput screening utilizing droplet microfluidics, device design and characterization for specific applications remain resource and time-intensive. To address these challenges, we present the development of an automated droplet microfluidic platform that combines rapid device prototyping, custom multi-modal sensing, and closed-loop control for high-throughput biological and chemical analysis. The work bridges the gap between traditional, expert-driven microfluidic operation and fully autonomous systems capable of real-time monitoring and regulation. This research establishes a foundation for scalable, miniaturized, and programmable droplet microfluidics. First, the co-design and characterization of impedance and luminescence sensors was integrated with micromilled polycarbonate microfluidic devices. Conductive-ink electrodes were optimized for droplet impedance detection. Additionally, a photodetector was characterized for real-time luminescence sensing of bioluminescence reactions in droplets. Together, these results defined the electronic and microfluidic parameters necessary for accurate droplet sensing at nanoliter scales. Building on this sensing foundation, we designed and fabricated a modular droplet microfluidic platform to generate, manipulate, and analyze droplets with integrated multi-modal sensing. The platform achieved precise control of droplet size and throughput through feedback-driven flow regulation and demonstrated compatibility with high-speed camera imaging, impedance, luminescence, and fluorescence readouts. Finally, we present the Droplet Microfluidic Automation Machine (DropMAM), a unified hardware–software framework that automates droplet microfluidic operation through integrated sensing and closed-loop control. DropMAM automates device operation, characterization, and data analysis using real-time, high-speed camera, impedance, luminescence, or fluorescence measurements to adjust flow rates and pressure dynamically. By implementing adaptive feedback, the system maintains user-defined droplet properties such as size, throughput, and injection volume, transforming microfluidic experimentation into a reproducible and self-regulating process. Overall, this work establishes a scalable framework for integrating electronic sensing and feedback automation into droplet microfluidics. By combining rapid microfabrication, high-speed electronic characterization, and real-time software control, this platform enables the autonomous execution of complex droplet workflows with high precision and throughput."],"dc:identifier.orcid":["0000-0002-3781-0328"],"dc:identifier.uri":["https://hdl.handle.net/2144/52135"],"dc:language.iso":["en_US"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Biomedical engineering","Automation","Droplet microfluidics","Error correction","Impedance sensing","Luminescence sensing","Multi-modal sensing"],"dc:title":["Droplet microfluidic platform automation with multi-modal sensing integration and closed-loop feedback"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-19T02:42:12Z"}