{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/52223"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/52223","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"A computer-based eye movement recording system using the scleral search-coil technique","abstract":"This eye-movement recording system uses the scleral search coil technique. It has two recording channels, which is extremely important in the binocular vision studies. It consists of four basic elements: magnetic field coils to generate horizontal and vertical oscillating magnetic fields, two ocular search coils to detect the eye positions, an eye movement monitor to separate and amplify the horizontal and vertical eye-movement signals, and a PDP11/23 data acquisition system to digitize the eye position signals and store them on the disk. Several programs analyze and plot the data. This system has recorded eye movements from normal subjects with high resolution, linearity, low drift, and low noise, when compared to other methods. This system will be used in ophthalmological clinical and basic research.","abstract_html":"This eye-movement recording system uses the scleral search coil technique. It has two recording channels, which is extremely important in the binocular vision studies. It consists of four basic elements: magnetic field coils to generate horizontal and vertical oscillating magnetic fields, two ocular search coils to detect the eye positions, an eye movement monitor to separate and amplify the horizontal and vertical eye-movement signals, and a PDP11/23 data acquisition system to digitize the eye position signals and store them on the disk. Several programs analyze and plot the data. This system has recorded eye movements from normal subjects with high resolution, linearity, low drift, and low noise, when compared to other methods. This system will be used in ophthalmological clinical and basic research.","abstract_has_math":false,"creators":["Fang, Jianjun"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1988,"date_issued":"1988","date_published":"1988","updated_at":"2026-11-19T02:42:12Z","subjects":[],"languages":["en_US"],"rights":["PLEASE NOTE: Boston University Libraries did not receive an Authorization To Manage form for this thesis or dissertation. It is therefore not openly accessible, though it may be available by request. If you are the author or principal advisor of this work and would like to request open access for it, please contact us at open-help@bu.edu. Thank you."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.barcode","label":"Dc Identifier Barcode","values":["11719013318862"],"render_values":[{"text":"11719013318862","href":null,"code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["99176938850001161"],"render_values":[{"text":"99176938850001161","href":null,"code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["b18053695"],"render_values":[{"text":"b18053695","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/52223","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/52223","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F52223","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Fang, Jianjun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-02-06T20:51:17Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2999-01-01T00:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["1988"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["1988"]},{"key":"dc:publisher","label":"Institution","values":["Boston University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["PLEASE NOTE: Boston University Libraries did not receive an Authorization To Manage form for this thesis or dissertation. It is therefore not openly accessible, though it may be available by request. If you are the author or principal advisor of this work and would like to request open access for it, please contact us at open-help@bu.edu. Thank you."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.barcode","label":"Dc Identifier Barcode","values":["11719013318862"]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["99176938850001161"]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["b18053695"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/52223"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (M.S.)--Boston University"]},{"key":"dc:description.abstract","label":"Abstract","values":["This eye-movement recording system uses the scleral search coil technique. It has two recording channels, which is extremely important in the binocular vision studies. It consists of four basic elements: magnetic field coils to generate horizontal and vertical oscillating magnetic fields, two ocular search coils to detect the eye positions, an eye movement monitor to separate and amplify the horizontal and vertical eye-movement signals, and a PDP11/23 data acquisition system to digitize the eye position signals and store them on the disk. Several programs analyze and plot the data. This system has recorded eye movements from normal subjects with high resolution, linearity, low drift, and low noise, when compared to other methods. This system will be used in ophthalmological clinical and basic research."]},{"key":"dc:title","label":"Title","values":["A computer-based eye movement recording system using the scleral search-coil technique"]}]}],"canonical_facts":{"dc:creator":["Fang, Jianjun"],"dc:date.accessioned":["2026-02-06T20:51:17Z"],"dc:date.embargo":["2999-01-01T00:00:00Z"],"dc:date.issued":["1988"],"dc:date.submitted":["1988"],"dc:description":["Thesis (M.S.)--Boston University"],"dc:description.abstract":["This eye-movement recording system uses the scleral search coil technique. It has two recording channels, which is extremely important in the binocular vision studies. It consists of four basic elements: magnetic field coils to generate horizontal and vertical oscillating magnetic fields, two ocular search coils to detect the eye positions, an eye movement monitor to separate and amplify the horizontal and vertical eye-movement signals, and a PDP11/23 data acquisition system to digitize the eye position signals and store them on the disk. Several programs analyze and plot the data. This system has recorded eye movements from normal subjects with high resolution, linearity, low drift, and low noise, when compared to other methods. This system will be used in ophthalmological clinical and basic research."],"dc:identifier.barcode":["11719013318862"],"dc:identifier.bibid":["99176938850001161"],"dc:identifier.other":["b18053695"],"dc:identifier.uri":["https://hdl.handle.net/2144/52223"],"dc:language.iso":["en_US"],"dc:publisher":["Boston University"],"dc:rights":["PLEASE NOTE: Boston University Libraries did not receive an Authorization To Manage form for this thesis or dissertation. It is therefore not openly accessible, though it may be available by request. If you are the author or principal advisor of this work and would like to request open access for it, please contact us at open-help@bu.edu. Thank you."],"dc:title":["A computer-based eye movement recording system using the scleral search-coil technique"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-19T02:42:12Z"}