{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/52331"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/52331","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Survey of low sperm count samples to determine amounts of non-sperm cell DNA present","abstract":"Metafer software offers a novel approach for quantifying sperm cells in forensic and clinical contexts. Its primary application lies in sperm detection and enumeration within semen samples, with the potential to complement traditional quantification methods such as quantitative polymerase chain reaction (qPCR). This study examined 28 low-sperm-count semen samples, comparing Metafer software sperm cell counts to DNA quantification results obtained using AcroSolv and differential extraction methods paired with qPCR. While Metafer software successfully identified and counted sperm cells, its calculated DNA mass values were significantly lower than those produced by qPCR, revealing limitations in its quantitative precision. Factors such as sample freezing, uneven slide preparation, and the presence of cell-free DNA (cfDNA) in semen samples further contributed to these discrepancies. In forensic settings, cfDNA—originating from sperm cell lysis or surrounding epithelial tissues—can confound DNA quantification and obscure male DNA profiles. Differential extraction techniques help mitigate this interference by isolating sperm DNA, but challenges remain, particularly in samples with low sperm counts or compromised cell integrity. Findings from this study demonstrate that Metafer software while promising for sperm detection, lacks the accuracy required to replace qPCR for DNA quantification.","abstract_html":"Metafer software offers a novel approach for quantifying sperm cells in forensic and clinical contexts. Its primary application lies in sperm detection and enumeration within semen samples, with the potential to complement traditional quantification methods such as quantitative polymerase chain reaction (qPCR). This study examined 28 low-sperm-count semen samples, comparing Metafer software sperm cell counts to DNA quantification results obtained using AcroSolv and differential extraction methods paired with qPCR. While Metafer software successfully identified and counted sperm cells, its calculated DNA mass values were significantly lower than those produced by qPCR, revealing limitations in its quantitative precision. Factors such as sample freezing, uneven slide preparation, and the presence of cell-free DNA (cfDNA) in semen samples further contributed to these discrepancies. In forensic settings, cfDNA—originating from sperm cell lysis or surrounding epithelial tissues—can confound DNA quantification and obscure male DNA profiles. Differential extraction techniques help mitigate this interference by isolating sperm DNA, but challenges remain, particularly in samples with low sperm counts or compromised cell integrity. Findings from this study demonstrate that Metafer software while promising for sperm detection, lacks the accuracy required to replace qPCR for DNA quantification.","abstract_has_math":false,"creators":["Li, Xuxiang"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Forensic Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Cotton, Robin W.","Kosiorek, Kevin"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-18T19:37:35Z","subjects":["Molecular biology","Biology","Cell-free DNA","DNA concentration","Forensic science","Metafer software","qPCR","Sperm cell"],"languages":["en_US"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/52331","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/52331","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F52331","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cotton, Robin W.","Kosiorek, Kevin"]},{"key":"dc:creator","label":"Author","values":["Li, Xuxiang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-02-18T16:16:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-02-18T16:16:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-02-14T02:06:39Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Forensic Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Molecular biology","Biology","Cell-free DNA","DNA concentration","Forensic science","Metafer software","qPCR","Sperm cell"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/52331"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["2025"]},{"key":"dc:description.abstract","label":"Abstract","values":["Metafer software offers a novel approach for quantifying sperm cells in forensic and clinical contexts. Its primary application lies in sperm detection and enumeration within semen samples, with the potential to complement traditional quantification methods such as quantitative polymerase chain reaction (qPCR). This study examined 28 low-sperm-count semen samples, comparing Metafer software sperm cell counts to DNA quantification results obtained using AcroSolv and differential extraction methods paired with qPCR. While Metafer software successfully identified and counted sperm cells, its calculated DNA mass values were significantly lower than those produced by qPCR, revealing limitations in its quantitative precision. Factors such as sample freezing, uneven slide preparation, and the presence of cell-free DNA (cfDNA) in semen samples further contributed to these discrepancies. In forensic settings, cfDNA—originating from sperm cell lysis or surrounding epithelial tissues—can confound DNA quantification and obscure male DNA profiles. Differential extraction techniques help mitigate this interference by isolating sperm DNA, but challenges remain, particularly in samples with low sperm counts or compromised cell integrity. Findings from this study demonstrate that Metafer software while promising for sperm detection, lacks the accuracy required to replace qPCR for DNA quantification."]},{"key":"dc:title","label":"Title","values":["Survey of low sperm count samples to determine amounts of non-sperm cell DNA present"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cotton, Robin W.","Kosiorek, Kevin"],"dc:creator":["Li, Xuxiang"],"dc:date.accessioned":["2026-02-18T16:16:21Z"],"dc:date.available":["2026-02-18T16:16:21Z"],"dc:date.issued":["2025"],"dc:date.updated":["2026-02-14T02:06:39Z"],"dc:description":["2025"],"dc:description.abstract":["Metafer software offers a novel approach for quantifying sperm cells in forensic and clinical contexts. Its primary application lies in sperm detection and enumeration within semen samples, with the potential to complement traditional quantification methods such as quantitative polymerase chain reaction (qPCR). This study examined 28 low-sperm-count semen samples, comparing Metafer software sperm cell counts to DNA quantification results obtained using AcroSolv and differential extraction methods paired with qPCR. While Metafer software successfully identified and counted sperm cells, its calculated DNA mass values were significantly lower than those produced by qPCR, revealing limitations in its quantitative precision. Factors such as sample freezing, uneven slide preparation, and the presence of cell-free DNA (cfDNA) in semen samples further contributed to these discrepancies. In forensic settings, cfDNA—originating from sperm cell lysis or surrounding epithelial tissues—can confound DNA quantification and obscure male DNA profiles. Differential extraction techniques help mitigate this interference by isolating sperm DNA, but challenges remain, particularly in samples with low sperm counts or compromised cell integrity. Findings from this study demonstrate that Metafer software while promising for sperm detection, lacks the accuracy required to replace qPCR for DNA quantification."],"dc:identifier.uri":["https://hdl.handle.net/2144/52331"],"dc:language.iso":["en_US"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Molecular biology","Biology","Cell-free DNA","DNA concentration","Forensic science","Metafer software","qPCR","Sperm cell"],"dc:title":["Survey of low sperm count samples to determine amounts of non-sperm cell DNA present"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Forensic Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:37:35Z"}