{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/53186"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/53186","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Comparing downstream qPCR and STR profile results of diluted samples using different direct lysis methods","abstract":"The forensic analysis of deoxyribonucleic acid (DNA) aims to procure a profile from DNA found on evidence samples or collected from known persons in order to establish linkages between victims, suspects and/or crime scenes. The end result is an electropherogram created via capillary electrophoresis (CE) that allows analysts to view a short tandem repeat (STR) profile of the DNA. DNA extraction is the first step in forensic DNA analysis, and direct lysis is often the preferred method for use with forensic samples, which are often degraded and low template. Direct lysis is colloquially known as the “quick and dirty” lysis method, as it is typically faster, and usually only requires one tube, meaning potential Polymerase Chain Reaction (PCR) inhibitors remain in the tube along with the lysate. Therefore, a strong contender for a direct lysis kit to be used on forensic samples is capable of producing high quality profiles even in the presence of potential inhibitors. Blood and semen are two body fluids commonly encountered at crime scenes and used as forensic DNA evidence. Both of these cell sources, however, pose challenges to the use of direct lysis. Blood contains heme, a PCR inhibitor, and sperm is made up of disulfide bonds, which require the use of a reducing agent in order to be broken for cellular lysis. The purpose of this study was to analyze and compare the ability of two different direct lysis kits to extract DNA from diluted blood and semen samples, and to eventually produce STR profiles.","abstract_html":"The forensic analysis of deoxyribonucleic acid (DNA) aims to procure a profile from DNA found on evidence samples or collected from known persons in order to establish linkages between victims, suspects and/or crime scenes. The end result is an electropherogram created via capillary electrophoresis (CE) that allows analysts to view a short tandem repeat (STR) profile of the DNA. DNA extraction is the first step in forensic DNA analysis, and direct lysis is often the preferred method for use with forensic samples, which are often degraded and low template. Direct lysis is colloquially known as the “quick and dirty” lysis method, as it is typically faster, and usually only requires one tube, meaning potential Polymerase Chain Reaction (PCR) inhibitors remain in the tube along with the lysate. Therefore, a strong contender for a direct lysis kit to be used on forensic samples is capable of producing high quality profiles even in the presence of potential inhibitors. Blood and semen are two body fluids commonly encountered at crime scenes and used as forensic DNA evidence. Both of these cell sources, however, pose challenges to the use of direct lysis. Blood contains heme, a PCR inhibitor, and sperm is made up of disulfide bonds, which require the use of a reducing agent in order to be broken for cellular lysis. The purpose of this study was to analyze and compare the ability of two different direct lysis kits to extract DNA from diluted blood and semen samples, and to eventually produce STR profiles.","abstract_has_math":false,"creators":["Morin, Emma Nancy"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Forensic Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Cotton, Robin W."],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-18T19:50:13Z","subjects":["Biology","Casework direct system","Chai enzymatic RNA/DNA extraction buffer","Direct lysis","DNA extraction"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/53186","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/53186","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F53186","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cotton, Robin W."]},{"key":"dc:creator","label":"Author","values":["Morin, Emma Nancy"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-06-18T16:49:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-06-18T16:49:07Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-06-17T19:02:44Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Forensic Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biology","Casework direct system","Chai enzymatic RNA/DNA extraction buffer","Direct lysis","DNA extraction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/53186"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["2025"]},{"key":"dc:description.abstract","label":"Abstract","values":["The forensic analysis of deoxyribonucleic acid (DNA) aims to procure a profile from DNA found on evidence samples or collected from known persons in order to establish linkages between victims, suspects and/or crime scenes. The end result is an electropherogram created via capillary electrophoresis (CE) that allows analysts to view a short tandem repeat (STR) profile of the DNA. DNA extraction is the first step in forensic DNA analysis, and direct lysis is often the preferred method for use with forensic samples, which are often degraded and low template. Direct lysis is colloquially known as the “quick and dirty” lysis method, as it is typically faster, and usually only requires one tube, meaning potential Polymerase Chain Reaction (PCR) inhibitors remain in the tube along with the lysate. Therefore, a strong contender for a direct lysis kit to be used on forensic samples is capable of producing high quality profiles even in the presence of potential inhibitors. Blood and semen are two body fluids commonly encountered at crime scenes and used as forensic DNA evidence. Both of these cell sources, however, pose challenges to the use of direct lysis. Blood contains heme, a PCR inhibitor, and sperm is made up of disulfide bonds, which require the use of a reducing agent in order to be broken for cellular lysis. The purpose of this study was to analyze and compare the ability of two different direct lysis kits to extract DNA from diluted blood and semen samples, and to eventually produce STR profiles."]},{"key":"dc:title","label":"Title","values":["Comparing downstream qPCR and STR profile results of diluted samples using different direct lysis methods"]}]}],"canonical_facts":{"dc:contributor.advisor":["Cotton, Robin W."],"dc:creator":["Morin, Emma Nancy"],"dc:date.accessioned":["2026-06-18T16:49:07Z"],"dc:date.available":["2026-06-18T16:49:07Z"],"dc:date.issued":["2025"],"dc:date.updated":["2026-06-17T19:02:44Z"],"dc:description":["2025"],"dc:description.abstract":["The forensic analysis of deoxyribonucleic acid (DNA) aims to procure a profile from DNA found on evidence samples or collected from known persons in order to establish linkages between victims, suspects and/or crime scenes. The end result is an electropherogram created via capillary electrophoresis (CE) that allows analysts to view a short tandem repeat (STR) profile of the DNA. DNA extraction is the first step in forensic DNA analysis, and direct lysis is often the preferred method for use with forensic samples, which are often degraded and low template. Direct lysis is colloquially known as the “quick and dirty” lysis method, as it is typically faster, and usually only requires one tube, meaning potential Polymerase Chain Reaction (PCR) inhibitors remain in the tube along with the lysate. Therefore, a strong contender for a direct lysis kit to be used on forensic samples is capable of producing high quality profiles even in the presence of potential inhibitors. Blood and semen are two body fluids commonly encountered at crime scenes and used as forensic DNA evidence. Both of these cell sources, however, pose challenges to the use of direct lysis. Blood contains heme, a PCR inhibitor, and sperm is made up of disulfide bonds, which require the use of a reducing agent in order to be broken for cellular lysis. The purpose of this study was to analyze and compare the ability of two different direct lysis kits to extract DNA from diluted blood and semen samples, and to eventually produce STR profiles."],"dc:identifier.uri":["https://hdl.handle.net/2144/53186"],"dc:language.iso":["en_US"],"dc:subject":["Biology","Casework direct system","Chai enzymatic RNA/DNA extraction buffer","Direct lysis","DNA extraction"],"dc:title":["Comparing downstream qPCR and STR profile results of diluted samples using different direct lysis methods"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Forensic Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:50:13Z"}