{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/53321"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/53321","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Assessment of mechanical properties and minimum printable thickness of definitive 3D-printed restorative materials across different printer platforms","abstract":"OBJECTIVES: This in vitro study evaluated the minimum printable thickness and mechanical properties of definitive 3D-printed restorative materials fabricated using different DLP printer platforms. The effects of material type and printer platform on dimensional accuracy, biaxial flexural strength (BFS), and three-point bending (3PB) flexural strength were investigated. The effect of thermocycling was evaluated only for BFS testing. MATERIALS AND METHODS: Five definitive printable restorative materials were evaluated: Asiga DentaTOOTH, Rodin Rapid Ceram, Rodin Sculpture 2, Pro Resin CrownX, and SprintRay Ceramic Crown. Minimum printable thickness was assessed using merlon geometries fabricated at thicknesses ranging from 0.1–0.5 mm (n = 5/specimen thickness per material). BFS specimens were fabricated under control (n = 12) and thermocycled conditions (n = 12), while 3PB specimens were fabricated with n = 12 per material. Specimens were fabricated using Asiga and SprintRay DLP printer systems. Statistical analysis included ANOVA, regression analysis of least squares means, Tukey HSD post hoc analysis, and Student’s t-tests (α = 0.05). RESULTS: Significant differences were observed across materials in printability, dimensional accuracy, and flexural properties. Most materials produced reliable, measurable geometries at thicknesses ≥0.3 mm. Sculpture 2 and Ceramic Crown showed higher overall flexural strength, whereas CrownX produced the most accurate printed geometries. Thermocycling significantly reduced BFS values and showed material-dependent effects. CONCLUSIONS: Definitive printable restorative materials demonstrated material- and printer-dependent differences in printability and mechanical performance. Thermocycling adversely affected BFS values, underscoring the importance of material selection and printer workflow for the long-term clinical performance of definitive 3D-printed restorations.","abstract_html":"OBJECTIVES: This in vitro study evaluated the minimum printable thickness and mechanical properties of definitive 3D-printed restorative materials fabricated using different DLP printer platforms. The effects of material type and printer platform on dimensional accuracy, biaxial flexural strength (BFS), and three-point bending (3PB) flexural strength were investigated. The effect of thermocycling was evaluated only for BFS testing. MATERIALS AND METHODS: Five definitive printable restorative materials were evaluated: Asiga DentaTOOTH, Rodin Rapid Ceram, Rodin Sculpture 2, Pro Resin CrownX, and SprintRay Ceramic Crown. Minimum printable thickness was assessed using merlon geometries fabricated at thicknesses ranging from 0.1–0.5 mm (n = 5/specimen thickness per material). BFS specimens were fabricated under control (n = 12) and thermocycled conditions (n = 12), while 3PB specimens were fabricated with n = 12 per material. Specimens were fabricated using Asiga and SprintRay DLP printer systems. Statistical analysis included ANOVA, regression analysis of least squares means, Tukey HSD post hoc analysis, and Student’s t-tests (α = 0.05). RESULTS: Significant differences were observed across materials in printability, dimensional accuracy, and flexural properties. Most materials produced reliable, measurable geometries at thicknesses ≥0.3 mm. Sculpture 2 and Ceramic Crown showed higher overall flexural strength, whereas CrownX produced the most accurate printed geometries. Thermocycling significantly reduced BFS values and showed material-dependent effects. CONCLUSIONS: Definitive printable restorative materials demonstrated material- and printer-dependent differences in printability and mechanical performance. Thermocycling adversely affected BFS values, underscoring the importance of material selection and printer workflow for the long-term clinical performance of definitive 3D-printed restorations.","abstract_has_math":false,"creators":["Meerza, Fadhel"],"institution":"Boston University","degree_name":"Master of Science in Design","degree_level":"masters","degree_discipline":"Restorative Sciences & Biomaterials","degree_department":null,"school":null,"contributors":[],"advisors":["Giordano, Russell, II","Fan, Yuwei"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T20:27:03Z","subjects":["Dentistry"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/53321","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/53321","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F53321","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Giordano, Russell, II","Fan, Yuwei"]},{"key":"dc:creator","label":"Author","values":["Meerza, Fadhel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-14T18:39:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-07-14T18:39:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-07-14T16:15:34Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Restorative Sciences & Biomaterials"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Design"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/53321"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["2026"]},{"key":"dc:description.abstract","label":"Abstract","values":["OBJECTIVES: This in vitro study evaluated the minimum printable thickness and mechanical properties of definitive 3D-printed restorative materials fabricated using different DLP printer platforms. The effects of material type and printer platform on dimensional accuracy, biaxial flexural strength (BFS), and three-point bending (3PB) flexural strength were investigated. The effect of thermocycling was evaluated only for BFS testing. MATERIALS AND METHODS: Five definitive printable restorative materials were evaluated: Asiga DentaTOOTH, Rodin Rapid Ceram, Rodin Sculpture 2, Pro Resin CrownX, and SprintRay Ceramic Crown. Minimum printable thickness was assessed using merlon geometries fabricated at thicknesses ranging from 0.1–0.5 mm (n = 5/specimen thickness per material). BFS specimens were fabricated under control (n = 12) and thermocycled conditions (n = 12), while 3PB specimens were fabricated with n = 12 per material. Specimens were fabricated using Asiga and SprintRay DLP printer systems. Statistical analysis included ANOVA, regression analysis of least squares means, Tukey HSD post hoc analysis, and Student’s t-tests (α = 0.05). RESULTS: Significant differences were observed across materials in printability, dimensional accuracy, and flexural properties. Most materials produced reliable, measurable geometries at thicknesses ≥0.3 mm. Sculpture 2 and Ceramic Crown showed higher overall flexural strength, whereas CrownX produced the most accurate printed geometries. Thermocycling significantly reduced BFS values and showed material-dependent effects. CONCLUSIONS: Definitive printable restorative materials demonstrated material- and printer-dependent differences in printability and mechanical performance. Thermocycling adversely affected BFS values, underscoring the importance of material selection and printer workflow for the long-term clinical performance of definitive 3D-printed restorations."]},{"key":"dc:title","label":"Title","values":["Assessment of mechanical properties and minimum printable thickness of definitive 3D-printed restorative materials across different printer platforms"]}]}],"canonical_facts":{"dc:contributor.advisor":["Giordano, Russell, II","Fan, Yuwei"],"dc:creator":["Meerza, Fadhel"],"dc:date.accessioned":["2026-07-14T18:39:15Z"],"dc:date.available":["2026-07-14T18:39:15Z"],"dc:date.issued":["2026"],"dc:date.updated":["2026-07-14T16:15:34Z"],"dc:description":["2026"],"dc:description.abstract":["OBJECTIVES: This in vitro study evaluated the minimum printable thickness and mechanical properties of definitive 3D-printed restorative materials fabricated using different DLP printer platforms. The effects of material type and printer platform on dimensional accuracy, biaxial flexural strength (BFS), and three-point bending (3PB) flexural strength were investigated. The effect of thermocycling was evaluated only for BFS testing. MATERIALS AND METHODS: Five definitive printable restorative materials were evaluated: Asiga DentaTOOTH, Rodin Rapid Ceram, Rodin Sculpture 2, Pro Resin CrownX, and SprintRay Ceramic Crown. Minimum printable thickness was assessed using merlon geometries fabricated at thicknesses ranging from 0.1–0.5 mm (n = 5/specimen thickness per material). BFS specimens were fabricated under control (n = 12) and thermocycled conditions (n = 12), while 3PB specimens were fabricated with n = 12 per material. Specimens were fabricated using Asiga and SprintRay DLP printer systems. Statistical analysis included ANOVA, regression analysis of least squares means, Tukey HSD post hoc analysis, and Student’s t-tests (α = 0.05). RESULTS: Significant differences were observed across materials in printability, dimensional accuracy, and flexural properties. Most materials produced reliable, measurable geometries at thicknesses ≥0.3 mm. Sculpture 2 and Ceramic Crown showed higher overall flexural strength, whereas CrownX produced the most accurate printed geometries. Thermocycling significantly reduced BFS values and showed material-dependent effects. CONCLUSIONS: Definitive printable restorative materials demonstrated material- and printer-dependent differences in printability and mechanical performance. Thermocycling adversely affected BFS values, underscoring the importance of material selection and printer workflow for the long-term clinical performance of definitive 3D-printed restorations."],"dc:identifier.uri":["https://hdl.handle.net/2144/53321"],"dc:language.iso":["en_US"],"dc:subject":["Dentistry"],"dc:title":["Assessment of mechanical properties and minimum printable thickness of definitive 3D-printed restorative materials across different printer platforms"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Restorative Sciences & Biomaterials"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Design"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T20:27:03Z"}