{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/53322"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/53322","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"A comparative biomechanical perspective on a new attachment design for premolar rotational movement with clear aligner therapy","abstract":"OBJECTIVES: Rotational tooth movement remains one of the least predictable outcomes in clear aligner therapy, particularly for premolars. This study aimed to evaluate the biomechanical performance of a novel attachment design for premolar rotation using finite element analysis, and to compare its effects with conventional fixed appliance mechanics based on coupled force systems. MATREIALS & METHODS: A three-dimensional mandibular model was used to simulate a 30° rotation of a first premolar. Two systems were analyzed: (i) fixed appliances employing elastomeric chains to generate a rotational couple, and (ii) clear aligners incorporating a novel attachment designed to produce comparable moments. Applied torques were calibrated to ensure equivalent initial rotational conditions. RESULTS: The aligner model demonstrated substantially lower stress magnitudes (by approximately two orders of magnitude) and a more uniform stress distribution localized to the target tooth. Despite a slightly lower applied torque (1.4 Nmm vs. 1.44 Nmm), the aligner system exhibited an approximately 17.5% greater onset rotation, indicating a more efficient expression of the applied moment. In contrast, the fixed appliance system showed higher stress concentrations extending to adjacent teeth and increased unintended rotational components. CONCLUSION: Displacement patterns confirmed that adjacent teeth in the aligner system primarily exhibited minor translational movement, whereas the fixed appliance system induced combined rotational and translational responses. Periodontal ligament strain patterns further supported these findings, with the aligner model showing strain localized to the rotated premolar, while strain in adjacent teeth was reduced on average by more than 94% compared to the fixed appliance system. These results indicate that this new attachment design with aligner systems may enable more localized and controlled rotational mechanics compared to conventional fixed appliance approaches.","abstract_html":"OBJECTIVES: Rotational tooth movement remains one of the least predictable outcomes in clear aligner therapy, particularly for premolars. This study aimed to evaluate the biomechanical performance of a novel attachment design for premolar rotation using finite element analysis, and to compare its effects with conventional fixed appliance mechanics based on coupled force systems. MATREIALS &amp; METHODS: A three-dimensional mandibular model was used to simulate a 30° rotation of a first premolar. Two systems were analyzed: (i) fixed appliances employing elastomeric chains to generate a rotational couple, and (ii) clear aligners incorporating a novel attachment designed to produce comparable moments. Applied torques were calibrated to ensure equivalent initial rotational conditions. RESULTS: The aligner model demonstrated substantially lower stress magnitudes (by approximately two orders of magnitude) and a more uniform stress distribution localized to the target tooth. Despite a slightly lower applied torque (1.4 Nmm vs. 1.44 Nmm), the aligner system exhibited an approximately 17.5% greater onset rotation, indicating a more efficient expression of the applied moment. In contrast, the fixed appliance system showed higher stress concentrations extending to adjacent teeth and increased unintended rotational components. CONCLUSION: Displacement patterns confirmed that adjacent teeth in the aligner system primarily exhibited minor translational movement, whereas the fixed appliance system induced combined rotational and translational responses. Periodontal ligament strain patterns further supported these findings, with the aligner model showing strain localized to the rotated premolar, while strain in adjacent teeth was reduced on average by more than 94% compared to the fixed appliance system. These results indicate that this new attachment design with aligner systems may enable more localized and controlled rotational mechanics compared to conventional fixed appliance approaches.","abstract_has_math":false,"creators":["Thomas, Lirin Ann"],"institution":"Boston University","degree_name":"Master of Science in Design","degree_level":"masters","degree_discipline":"Restorative Sciences & Biomaterials","degree_department":null,"school":null,"contributors":[],"advisors":["Tsouknidas, Alexandros"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T02:42:12Z","subjects":["Dentistry","Biomechanics","Clear aligners","Fixed appliances","Premolar rotation"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[{"key":"dc:identifier.orcid","label":"ORCID","values":["0000-0002-1483-5389"],"render_values":[{"text":"0000-0002-1483-5389","href":"https://orcid.org/0000-0002-1483-5389","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/2144/53322","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/53322","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F53322","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Tsouknidas, Alexandros"]},{"key":"dc:creator","label":"Author","values":["Thomas, Lirin Ann"]},{"key":"dc:identifier.orcid","label":"ORCID","values":["0000-0002-1483-5389"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-14T18:59:33Z"]},{"key":"dc:date.embargo","label":"Dc Date Embargo","values":["2028-07-14T00:00:00Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-07-14T16:15:31Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Restorative Sciences & Biomaterials"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Design"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry","Biomechanics","Clear aligners","Fixed appliances","Premolar rotation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/53322"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["2026"]},{"key":"dc:description.abstract","label":"Abstract","values":["OBJECTIVES: Rotational tooth movement remains one of the least predictable outcomes in clear aligner therapy, particularly for premolars. This study aimed to evaluate the biomechanical performance of a novel attachment design for premolar rotation using finite element analysis, and to compare its effects with conventional fixed appliance mechanics based on coupled force systems. MATREIALS & METHODS: A three-dimensional mandibular model was used to simulate a 30° rotation of a first premolar. Two systems were analyzed: (i) fixed appliances employing elastomeric chains to generate a rotational couple, and (ii) clear aligners incorporating a novel attachment designed to produce comparable moments. Applied torques were calibrated to ensure equivalent initial rotational conditions. RESULTS: The aligner model demonstrated substantially lower stress magnitudes (by approximately two orders of magnitude) and a more uniform stress distribution localized to the target tooth. Despite a slightly lower applied torque (1.4 Nmm vs. 1.44 Nmm), the aligner system exhibited an approximately 17.5% greater onset rotation, indicating a more efficient expression of the applied moment. In contrast, the fixed appliance system showed higher stress concentrations extending to adjacent teeth and increased unintended rotational components. CONCLUSION: Displacement patterns confirmed that adjacent teeth in the aligner system primarily exhibited minor translational movement, whereas the fixed appliance system induced combined rotational and translational responses. Periodontal ligament strain patterns further supported these findings, with the aligner model showing strain localized to the rotated premolar, while strain in adjacent teeth was reduced on average by more than 94% compared to the fixed appliance system. These results indicate that this new attachment design with aligner systems may enable more localized and controlled rotational mechanics compared to conventional fixed appliance approaches."]},{"key":"dc:title","label":"Title","values":["A comparative biomechanical perspective on a new attachment design for premolar rotational movement with clear aligner therapy"]}]}],"canonical_facts":{"dc:contributor.advisor":["Tsouknidas, Alexandros"],"dc:creator":["Thomas, Lirin Ann"],"dc:date.accessioned":["2026-07-14T18:59:33Z"],"dc:date.embargo":["2028-07-14T00:00:00Z"],"dc:date.issued":["2026"],"dc:date.updated":["2026-07-14T16:15:31Z"],"dc:description":["2026"],"dc:description.abstract":["OBJECTIVES: Rotational tooth movement remains one of the least predictable outcomes in clear aligner therapy, particularly for premolars. This study aimed to evaluate the biomechanical performance of a novel attachment design for premolar rotation using finite element analysis, and to compare its effects with conventional fixed appliance mechanics based on coupled force systems. MATREIALS & METHODS: A three-dimensional mandibular model was used to simulate a 30° rotation of a first premolar. Two systems were analyzed: (i) fixed appliances employing elastomeric chains to generate a rotational couple, and (ii) clear aligners incorporating a novel attachment designed to produce comparable moments. Applied torques were calibrated to ensure equivalent initial rotational conditions. RESULTS: The aligner model demonstrated substantially lower stress magnitudes (by approximately two orders of magnitude) and a more uniform stress distribution localized to the target tooth. Despite a slightly lower applied torque (1.4 Nmm vs. 1.44 Nmm), the aligner system exhibited an approximately 17.5% greater onset rotation, indicating a more efficient expression of the applied moment. In contrast, the fixed appliance system showed higher stress concentrations extending to adjacent teeth and increased unintended rotational components. CONCLUSION: Displacement patterns confirmed that adjacent teeth in the aligner system primarily exhibited minor translational movement, whereas the fixed appliance system induced combined rotational and translational responses. Periodontal ligament strain patterns further supported these findings, with the aligner model showing strain localized to the rotated premolar, while strain in adjacent teeth was reduced on average by more than 94% compared to the fixed appliance system. These results indicate that this new attachment design with aligner systems may enable more localized and controlled rotational mechanics compared to conventional fixed appliance approaches."],"dc:identifier.orcid":["0000-0002-1483-5389"],"dc:identifier.uri":["https://hdl.handle.net/2144/53322"],"dc:language.iso":["en_US"],"dc:subject":["Dentistry","Biomechanics","Clear aligners","Fixed appliances","Premolar rotation"],"dc:title":["A comparative biomechanical perspective on a new attachment design for premolar rotational movement with clear aligner therapy"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Restorative Sciences & Biomaterials"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Design"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-19T02:42:12Z"}