{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/53326"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/53326","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Pilot study evaluating the EZ Guide endodontic sensor holder: feasibility and radiographic performance for canal separation in mandibular molars","abstract":"Accurate radiographic imaging is fundamental to successful endodontic treatment, yet conventional sensor holders lack precision for reproducible off-angle radiographs. Canal superimposition in multirooted teeth remains a significant diagnostic challenge, often necessitating multiple exposures and extending treatment time. This pilot study evaluated the feasibility and radiographic performance of the EZ Guide, a modified endodontic sensor holder with a preset 26-degree horizontal angulation, compared with conventional Rinn sensor holders for detecting canal separation in mandibular molars. Sixteen patients undergoing nonsurgical root canal treatment on mandibular molars with two or more mesial canals were enrolled at the Boston University Postdoctoral Endodontics Department. Each patient received standard radiographs using the Rinn sensor holder and one additional off-angle periapical radiograph using the EZ Guide during working length determination. Outcomes were assessed in two domains. The first was radiographic coverage quality, assessed using five binary parameters (working-length diagnostic acceptability, cone cut, apical cut-off, periapical area missing, and coronal cut-off). The second was canal separation, measured as the distance between the mesiobuccal and mesiolingual canal files at four root levels. Device usability was assessed qualitatively. The EZ Guide produced numerically greater canal separation than Rinn across all measured root regions (coronal, middle, apical thirds, and apex). The middle and apical thirds showed medium effect sizes (Cohen's d = 0.53 to 0.54) with mean separation increases of +0.30 to +0.40 mm. Cone-cut frequency was reduced by half with EZ Guide (12.5% versus 25.0%). However, no outcome reached statistical significance after Bonferroni correction. The main limitation was periapical region exclusion (50% of EZ Guide images versus 18.8% of Rinn images), attributable to prototype-specific ring geometry rather than the angulation concept itself. This pilot study demonstrates the feasibility and promise of standardized horizontal angulation for endodontic radiography, but a refined device and larger confirmatory study are required.","abstract_html":"Accurate radiographic imaging is fundamental to successful endodontic treatment, yet conventional sensor holders lack precision for reproducible off-angle radiographs. Canal superimposition in multirooted teeth remains a significant diagnostic challenge, often necessitating multiple exposures and extending treatment time. This pilot study evaluated the feasibility and radiographic performance of the EZ Guide, a modified endodontic sensor holder with a preset 26-degree horizontal angulation, compared with conventional Rinn sensor holders for detecting canal separation in mandibular molars. Sixteen patients undergoing nonsurgical root canal treatment on mandibular molars with two or more mesial canals were enrolled at the Boston University Postdoctoral Endodontics Department. Each patient received standard radiographs using the Rinn sensor holder and one additional off-angle periapical radiograph using the EZ Guide during working length determination. Outcomes were assessed in two domains. The first was radiographic coverage quality, assessed using five binary parameters (working-length diagnostic acceptability, cone cut, apical cut-off, periapical area missing, and coronal cut-off). The second was canal separation, measured as the distance between the mesiobuccal and mesiolingual canal files at four root levels. Device usability was assessed qualitatively. The EZ Guide produced numerically greater canal separation than Rinn across all measured root regions (coronal, middle, apical thirds, and apex). The middle and apical thirds showed medium effect sizes (Cohen&#x27;s d = 0.53 to 0.54) with mean separation increases of +0.30 to +0.40 mm. Cone-cut frequency was reduced by half with EZ Guide (12.5% versus 25.0%). However, no outcome reached statistical significance after Bonferroni correction. The main limitation was periapical region exclusion (50% of EZ Guide images versus 18.8% of Rinn images), attributable to prototype-specific ring geometry rather than the angulation concept itself. This pilot study demonstrates the feasibility and promise of standardized horizontal angulation for endodontic radiography, but a refined device and larger confirmatory study are required.","abstract_has_math":false,"creators":["Enayati, Sadaf"],"institution":"Boston University","degree_name":"Master of Science in Design","degree_level":"masters","degree_discipline":"Endodontics","degree_department":null,"school":null,"contributors":[],"advisors":["Alikhani, Kathy","Chogle, Sami"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T20:27:37Z","subjects":["Dentistry"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/53326","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/53326","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F53326","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Alikhani, Kathy","Chogle, Sami"]},{"key":"dc:creator","label":"Author","values":["Enayati, Sadaf"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-15T14:07:44Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-07-15T14:07:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-07-14T16:15:26Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Endodontics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Design"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/53326"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["2026"]},{"key":"dc:description.abstract","label":"Abstract","values":["Accurate radiographic imaging is fundamental to successful endodontic treatment, yet conventional sensor holders lack precision for reproducible off-angle radiographs. Canal superimposition in multirooted teeth remains a significant diagnostic challenge, often necessitating multiple exposures and extending treatment time. This pilot study evaluated the feasibility and radiographic performance of the EZ Guide, a modified endodontic sensor holder with a preset 26-degree horizontal angulation, compared with conventional Rinn sensor holders for detecting canal separation in mandibular molars. Sixteen patients undergoing nonsurgical root canal treatment on mandibular molars with two or more mesial canals were enrolled at the Boston University Postdoctoral Endodontics Department. Each patient received standard radiographs using the Rinn sensor holder and one additional off-angle periapical radiograph using the EZ Guide during working length determination. Outcomes were assessed in two domains. The first was radiographic coverage quality, assessed using five binary parameters (working-length diagnostic acceptability, cone cut, apical cut-off, periapical area missing, and coronal cut-off). The second was canal separation, measured as the distance between the mesiobuccal and mesiolingual canal files at four root levels. Device usability was assessed qualitatively. The EZ Guide produced numerically greater canal separation than Rinn across all measured root regions (coronal, middle, apical thirds, and apex). The middle and apical thirds showed medium effect sizes (Cohen's d = 0.53 to 0.54) with mean separation increases of +0.30 to +0.40 mm. Cone-cut frequency was reduced by half with EZ Guide (12.5% versus 25.0%). However, no outcome reached statistical significance after Bonferroni correction. The main limitation was periapical region exclusion (50% of EZ Guide images versus 18.8% of Rinn images), attributable to prototype-specific ring geometry rather than the angulation concept itself. This pilot study demonstrates the feasibility and promise of standardized horizontal angulation for endodontic radiography, but a refined device and larger confirmatory study are required."]},{"key":"dc:title","label":"Title","values":["Pilot study evaluating the EZ Guide endodontic sensor holder: feasibility and radiographic performance for canal separation in mandibular molars"]}]}],"canonical_facts":{"dc:contributor.advisor":["Alikhani, Kathy","Chogle, Sami"],"dc:creator":["Enayati, Sadaf"],"dc:date.accessioned":["2026-07-15T14:07:44Z"],"dc:date.available":["2026-07-15T14:07:44Z"],"dc:date.issued":["2026"],"dc:date.updated":["2026-07-14T16:15:26Z"],"dc:description":["2026"],"dc:description.abstract":["Accurate radiographic imaging is fundamental to successful endodontic treatment, yet conventional sensor holders lack precision for reproducible off-angle radiographs. Canal superimposition in multirooted teeth remains a significant diagnostic challenge, often necessitating multiple exposures and extending treatment time. This pilot study evaluated the feasibility and radiographic performance of the EZ Guide, a modified endodontic sensor holder with a preset 26-degree horizontal angulation, compared with conventional Rinn sensor holders for detecting canal separation in mandibular molars. Sixteen patients undergoing nonsurgical root canal treatment on mandibular molars with two or more mesial canals were enrolled at the Boston University Postdoctoral Endodontics Department. Each patient received standard radiographs using the Rinn sensor holder and one additional off-angle periapical radiograph using the EZ Guide during working length determination. Outcomes were assessed in two domains. The first was radiographic coverage quality, assessed using five binary parameters (working-length diagnostic acceptability, cone cut, apical cut-off, periapical area missing, and coronal cut-off). The second was canal separation, measured as the distance between the mesiobuccal and mesiolingual canal files at four root levels. Device usability was assessed qualitatively. The EZ Guide produced numerically greater canal separation than Rinn across all measured root regions (coronal, middle, apical thirds, and apex). The middle and apical thirds showed medium effect sizes (Cohen's d = 0.53 to 0.54) with mean separation increases of +0.30 to +0.40 mm. Cone-cut frequency was reduced by half with EZ Guide (12.5% versus 25.0%). However, no outcome reached statistical significance after Bonferroni correction. The main limitation was periapical region exclusion (50% of EZ Guide images versus 18.8% of Rinn images), attributable to prototype-specific ring geometry rather than the angulation concept itself. This pilot study demonstrates the feasibility and promise of standardized horizontal angulation for endodontic radiography, but a refined device and larger confirmatory study are required."],"dc:identifier.uri":["https://hdl.handle.net/2144/53326"],"dc:language.iso":["en_US"],"dc:subject":["Dentistry"],"dc:title":["Pilot study evaluating the EZ Guide endodontic sensor holder: feasibility and radiographic performance for canal separation in mandibular molars"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Endodontics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science in Design"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T20:27:37Z"}