{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/53484"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/53484","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Chemometric classification of ignitable liquids using direct analysis in real time – mass spectrometry (DART-MS)","abstract":"The use of DART-MS in the field of forensic science has attracted a lot of interest due to its rapid ionization and minimal sample preparation requirements. This study focused on coupling the use of DART as the ionization source to a mass spectrometer and analyzing the data acquired using the MassMountaineerTM software. Using the software, multiple chemometric approaches including PCA, KPCA, and KDA were completed to see if the mass spectral data generated from the DART can be used to develop and train a model to recognize the key signature patterns associated with four different types of ignitable liquid classes (LPD, MPD, gasoline, and aromatics) per ASTM Guidelines. The training set showed promising results in proper classification when experimenting with the known reference samples – with KDA showing exceptional results. In contrast, in the single blind study with three unknown samples, the chemometric approach failed to show utility in proper classification. All three of the unknown samples were misidentified despite the high accuracy anticipated with the KDA model with its Analysis of Variance percentage of 92.41%. Diversifying the sample types and increasing the sample size is expected to help enhance the statistical power of the models and further assist with the validation of using chemometrics in ignitable liquid data acquired using DART-MS as the methodology.","abstract_html":"The use of DART-MS in the field of forensic science has attracted a lot of interest due to its rapid ionization and minimal sample preparation requirements. This study focused on coupling the use of DART as the ionization source to a mass spectrometer and analyzing the data acquired using the MassMountaineerTM software. Using the software, multiple chemometric approaches including PCA, KPCA, and KDA were completed to see if the mass spectral data generated from the DART can be used to develop and train a model to recognize the key signature patterns associated with four different types of ignitable liquid classes (LPD, MPD, gasoline, and aromatics) per ASTM Guidelines. The training set showed promising results in proper classification when experimenting with the known reference samples – with KDA showing exceptional results. In contrast, in the single blind study with three unknown samples, the chemometric approach failed to show utility in proper classification. All three of the unknown samples were misidentified despite the high accuracy anticipated with the KDA model with its Analysis of Variance percentage of 92.41%. Diversifying the sample types and increasing the sample size is expected to help enhance the statistical power of the models and further assist with the validation of using chemometrics in ignitable liquid data acquired using DART-MS as the methodology.","abstract_has_math":false,"creators":["Kim, Miji"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Forensic Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Hall, Adam B."],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T19:38:35Z","subjects":["Forensic sciences","Chemometrics","DART-MS","Fire debris","Forensic chemistry","Ignitable liquids"],"languages":["en_US"],"rights":["Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/53484","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/53484","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F53484","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hall, Adam B."]},{"key":"dc:creator","label":"Author","values":["Kim, Miji"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-17T18:54:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-17T18:54:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-09-16T16:15:40Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Forensic Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Forensic sciences","Chemometrics","DART-MS","Fire debris","Forensic chemistry","Ignitable liquids"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/53484"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["2026"]},{"key":"dc:description.abstract","label":"Abstract","values":["The use of DART-MS in the field of forensic science has attracted a lot of interest due to its rapid ionization and minimal sample preparation requirements. This study focused on coupling the use of DART as the ionization source to a mass spectrometer and analyzing the data acquired using the MassMountaineerTM software. Using the software, multiple chemometric approaches including PCA, KPCA, and KDA were completed to see if the mass spectral data generated from the DART can be used to develop and train a model to recognize the key signature patterns associated with four different types of ignitable liquid classes (LPD, MPD, gasoline, and aromatics) per ASTM Guidelines. The training set showed promising results in proper classification when experimenting with the known reference samples – with KDA showing exceptional results. In contrast, in the single blind study with three unknown samples, the chemometric approach failed to show utility in proper classification. All three of the unknown samples were misidentified despite the high accuracy anticipated with the KDA model with its Analysis of Variance percentage of 92.41%. Diversifying the sample types and increasing the sample size is expected to help enhance the statistical power of the models and further assist with the validation of using chemometrics in ignitable liquid data acquired using DART-MS as the methodology."]},{"key":"dc:title","label":"Title","values":["Chemometric classification of ignitable liquids using direct analysis in real time – mass spectrometry (DART-MS)"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hall, Adam B."],"dc:creator":["Kim, Miji"],"dc:date.accessioned":["2026-09-17T18:54:49Z"],"dc:date.available":["2026-09-17T18:54:49Z"],"dc:date.issued":["2026"],"dc:date.updated":["2026-09-16T16:15:40Z"],"dc:description":["2026"],"dc:description.abstract":["The use of DART-MS in the field of forensic science has attracted a lot of interest due to its rapid ionization and minimal sample preparation requirements. This study focused on coupling the use of DART as the ionization source to a mass spectrometer and analyzing the data acquired using the MassMountaineerTM software. Using the software, multiple chemometric approaches including PCA, KPCA, and KDA were completed to see if the mass spectral data generated from the DART can be used to develop and train a model to recognize the key signature patterns associated with four different types of ignitable liquid classes (LPD, MPD, gasoline, and aromatics) per ASTM Guidelines. The training set showed promising results in proper classification when experimenting with the known reference samples – with KDA showing exceptional results. In contrast, in the single blind study with three unknown samples, the chemometric approach failed to show utility in proper classification. All three of the unknown samples were misidentified despite the high accuracy anticipated with the KDA model with its Analysis of Variance percentage of 92.41%. Diversifying the sample types and increasing the sample size is expected to help enhance the statistical power of the models and further assist with the validation of using chemometrics in ignitable liquid data acquired using DART-MS as the methodology."],"dc:identifier.uri":["https://hdl.handle.net/2144/53484"],"dc:language.iso":["en_US"],"dc:rights":["Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Forensic sciences","Chemometrics","DART-MS","Fire debris","Forensic chemistry","Ignitable liquids"],"dc:title":["Chemometric classification of ignitable liquids using direct analysis in real time – mass spectrometry (DART-MS)"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Forensic Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:38:35Z"}