{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/53495"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/53495","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Rapid active pharmaceutical ingredient (API) identification of unknown tablets using portable Raman spectroscopy for on-scene analysis","abstract":"This thesis explores the capability of utilizing a handheld Raman spectrometer for rapid on-site detection of pharmaceutical tablets in a two-part experiment. The Rigaku. CQL Max-ID handheld 1064 nm Raman Analyzer was used to detect the active pharmaceutical ingredient (API) of forty randomly selected tablets. Three scans were accumulated per tablet; first side of whole tablet, second side of whole tablet, and crushed form of tablet. Results from Part I conclude that twenty-seven tablets exhibited API detection in all or any of the three scans. A major trend correlation was noticed between increasing API concentration and detection of API by the device, specifically in the nine tablets containing more than one API, whereby API from that combination that held the highest concentration was always detected. In Part II, a custom standard library was created in the device for observations of possible matches between scans from known and unknown tablets. Ten standards of similar tablet characteristics were implemented and compared to five unknown tablets selected from this standard group. From the five, the device made three correct matches. Of the two that were incorrect, a shared API was noticed between them and the standard tablet they were mistaken for. Overall, with minimal sample preparation and minimal scan duration time, the application of portable Raman spectroscopy in scene investigation is valuable for API identification of unknown tablets.","abstract_html":"This thesis explores the capability of utilizing a handheld Raman spectrometer for rapid on-site detection of pharmaceutical tablets in a two-part experiment. The Rigaku. CQL Max-ID handheld 1064 nm Raman Analyzer was used to detect the active pharmaceutical ingredient (API) of forty randomly selected tablets. Three scans were accumulated per tablet; first side of whole tablet, second side of whole tablet, and crushed form of tablet. Results from Part I conclude that twenty-seven tablets exhibited API detection in all or any of the three scans. A major trend correlation was noticed between increasing API concentration and detection of API by the device, specifically in the nine tablets containing more than one API, whereby API from that combination that held the highest concentration was always detected. In Part II, a custom standard library was created in the device for observations of possible matches between scans from known and unknown tablets. Ten standards of similar tablet characteristics were implemented and compared to five unknown tablets selected from this standard group. From the five, the device made three correct matches. Of the two that were incorrect, a shared API was noticed between them and the standard tablet they were mistaken for. Overall, with minimal sample preparation and minimal scan duration time, the application of portable Raman spectroscopy in scene investigation is valuable for API identification of unknown tablets.","abstract_has_math":false,"creators":["Laforest, Isabella Albano"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Forensic Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Hall, Adam B."],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T19:45:59Z","subjects":["Forensic sciences"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/53495","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/53495","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F53495","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hall, Adam B."]},{"key":"dc:creator","label":"Author","values":["Laforest, Isabella Albano"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-18T15:23:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-18T15:23:15Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-09-16T16:15:33Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Forensic Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Forensic sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/53495"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["2026"]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis explores the capability of utilizing a handheld Raman spectrometer for rapid on-site detection of pharmaceutical tablets in a two-part experiment. The Rigaku. CQL Max-ID handheld 1064 nm Raman Analyzer was used to detect the active pharmaceutical ingredient (API) of forty randomly selected tablets. Three scans were accumulated per tablet; first side of whole tablet, second side of whole tablet, and crushed form of tablet. Results from Part I conclude that twenty-seven tablets exhibited API detection in all or any of the three scans. A major trend correlation was noticed between increasing API concentration and detection of API by the device, specifically in the nine tablets containing more than one API, whereby API from that combination that held the highest concentration was always detected. In Part II, a custom standard library was created in the device for observations of possible matches between scans from known and unknown tablets. Ten standards of similar tablet characteristics were implemented and compared to five unknown tablets selected from this standard group. From the five, the device made three correct matches. Of the two that were incorrect, a shared API was noticed between them and the standard tablet they were mistaken for. Overall, with minimal sample preparation and minimal scan duration time, the application of portable Raman spectroscopy in scene investigation is valuable for API identification of unknown tablets."]},{"key":"dc:title","label":"Title","values":["Rapid active pharmaceutical ingredient (API) identification of unknown tablets using portable Raman spectroscopy for on-scene analysis"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hall, Adam B."],"dc:creator":["Laforest, Isabella Albano"],"dc:date.accessioned":["2026-09-18T15:23:15Z"],"dc:date.available":["2026-09-18T15:23:15Z"],"dc:date.issued":["2026"],"dc:date.updated":["2026-09-16T16:15:33Z"],"dc:description":["2026"],"dc:description.abstract":["This thesis explores the capability of utilizing a handheld Raman spectrometer for rapid on-site detection of pharmaceutical tablets in a two-part experiment. The Rigaku. CQL Max-ID handheld 1064 nm Raman Analyzer was used to detect the active pharmaceutical ingredient (API) of forty randomly selected tablets. Three scans were accumulated per tablet; first side of whole tablet, second side of whole tablet, and crushed form of tablet. Results from Part I conclude that twenty-seven tablets exhibited API detection in all or any of the three scans. A major trend correlation was noticed between increasing API concentration and detection of API by the device, specifically in the nine tablets containing more than one API, whereby API from that combination that held the highest concentration was always detected. In Part II, a custom standard library was created in the device for observations of possible matches between scans from known and unknown tablets. Ten standards of similar tablet characteristics were implemented and compared to five unknown tablets selected from this standard group. From the five, the device made three correct matches. Of the two that were incorrect, a shared API was noticed between them and the standard tablet they were mistaken for. Overall, with minimal sample preparation and minimal scan duration time, the application of portable Raman spectroscopy in scene investigation is valuable for API identification of unknown tablets."],"dc:identifier.uri":["https://hdl.handle.net/2144/53495"],"dc:language.iso":["en_US"],"dc:subject":["Forensic sciences"],"dc:title":["Rapid active pharmaceutical ingredient (API) identification of unknown tablets using portable Raman spectroscopy for on-scene analysis"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Forensic Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:45:59Z"}