{"id":{"repo_id":"bu","oai_identifier":"oai:open.bu.edu:2144/53797"},"canonical_url":"https://search.ndltd.org/etd/bu/oai:open.bu.edu:2144/53797","repository":{"repo_id":"bu","name":"Boston University","base_url":"https://open.bu.edu/oai/request"},"display":{"title":"Expiration, collection, and storage: a multi-factor investigation of blood alcohol concentration","abstract":"A frequently encountered argument in impaired driving cases involving blood alcohol concentrations (BAC) is that ethanol (EtOH) levels may have been produced post-collection via microbial fermentation. Prior studies have independently refuted the effects of factors such as tube expiration status, collection method, and blood glucose level. This study, however, assessed the validity of these concerns collectively utilizing standard-issue 10 milliliter (mL) BD Vacutainer® Grey-Top Tubes containing 100 milligrams (mg) of sodium fluoride and 20 mg of potassium oxalate. Expired and unexpired blood collection tubes were compared under a variety of environmental conditions intended to simulate common collection scenarios. These scenarios involved following the recommended collection technique and leaving the tubes uncapped for 1 hour on a laboratory bench, in a restroom, or outdoors. Following exposure, the tubes were loaded with 5 mL of hyperglycemic leukocyte-reduced bank blood, with glucose levels in excess of 300 milligrams per deciliter (mg/dL), artificially spiked with EtOH to a target concentration of 0.08 grams/100 milliliters (gm%), and placed into one of the three storage conditions for two weeks: refrigerated at a temperature of 2 to 8 degrees Celsius (℃), room temperature at 20 to 25 ℃, and in a vehicle trunk with an outdoor temperature of, on average, 24.8 to 31.6 ℃. Upon completion of the two-week storage period, all samples were stored in a refrigerated storage vault prior to analysis to simulate real-world conditions. Three BAC measurements were performed on the samples: an initial baseline measurement before storage, a second analysis following the two-week storage period, and a final analysis after six and a half months of refrigerated storage. The results of this study indicate that there is no significant effect on BAC levels when using a 10 mL BD Vacutainer® tube past its expiration date. No de novo EtOH synthesis was detected; all ethanol-negative samples yielded non-detectable BAC measurements throughout the study. No significant differences in BAC levels were observed among the various simulated collection environments. The most significant decrease in EtOH concentration occurred in samples stored in the vehicle trunk, followed by those stored at room temperature; refrigerated samples showed the smallest decrease.","abstract_html":"A frequently encountered argument in impaired driving cases involving blood alcohol concentrations (BAC) is that ethanol (EtOH) levels may have been produced post-collection via microbial fermentation. Prior studies have independently refuted the effects of factors such as tube expiration status, collection method, and blood glucose level. This study, however, assessed the validity of these concerns collectively utilizing standard-issue 10 milliliter (mL) BD Vacutainer® Grey-Top Tubes containing 100 milligrams (mg) of sodium fluoride and 20 mg of potassium oxalate. Expired and unexpired blood collection tubes were compared under a variety of environmental conditions intended to simulate common collection scenarios. These scenarios involved following the recommended collection technique and leaving the tubes uncapped for 1 hour on a laboratory bench, in a restroom, or outdoors. Following exposure, the tubes were loaded with 5 mL of hyperglycemic leukocyte-reduced bank blood, with glucose levels in excess of 300 milligrams per deciliter (mg/dL), artificially spiked with EtOH to a target concentration of 0.08 grams/100 milliliters (gm%), and placed into one of the three storage conditions for two weeks: refrigerated at a temperature of 2 to 8 degrees Celsius (℃), room temperature at 20 to 25 ℃, and in a vehicle trunk with an outdoor temperature of, on average, 24.8 to 31.6 ℃. Upon completion of the two-week storage period, all samples were stored in a refrigerated storage vault prior to analysis to simulate real-world conditions. Three BAC measurements were performed on the samples: an initial baseline measurement before storage, a second analysis following the two-week storage period, and a final analysis after six and a half months of refrigerated storage. The results of this study indicate that there is no significant effect on BAC levels when using a 10 mL BD Vacutainer® tube past its expiration date. No de novo EtOH synthesis was detected; all ethanol-negative samples yielded non-detectable BAC measurements throughout the study. No significant differences in BAC levels were observed among the various simulated collection environments. The most significant decrease in EtOH concentration occurred in samples stored in the vehicle trunk, followed by those stored at room temperature; refrigerated samples showed the smallest decrease.","abstract_has_math":false,"creators":["Woolley, Roth Cook Sinclair"],"institution":"Boston University","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical Forensic Sciences","degree_department":null,"school":null,"contributors":[],"advisors":["Wareing, Celeste M"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-18T19:23:57Z","subjects":["Toxicology","Forensic sciences","Blood alcohol testing","Ethanol","Glucose"],"languages":["en_US"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2144/53797","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/2144/53797","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://open.bu.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aopen.bu.edu%3A2144%2F53797","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wareing, Celeste M"]},{"key":"dc:creator","label":"Author","values":["Woolley, Roth Cook Sinclair"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-10-23T15:48:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-10-23T15:48:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-08-26T16:17:53Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis/Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Forensic Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Boston University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Toxicology","Forensic sciences","Blood alcohol testing","Ethanol","Glucose"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/2144/53797"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["2026"]},{"key":"dc:description.abstract","label":"Abstract","values":["A frequently encountered argument in impaired driving cases involving blood alcohol concentrations (BAC) is that ethanol (EtOH) levels may have been produced post-collection via microbial fermentation. Prior studies have independently refuted the effects of factors such as tube expiration status, collection method, and blood glucose level. This study, however, assessed the validity of these concerns collectively utilizing standard-issue 10 milliliter (mL) BD Vacutainer® Grey-Top Tubes containing 100 milligrams (mg) of sodium fluoride and 20 mg of potassium oxalate. Expired and unexpired blood collection tubes were compared under a variety of environmental conditions intended to simulate common collection scenarios. These scenarios involved following the recommended collection technique and leaving the tubes uncapped for 1 hour on a laboratory bench, in a restroom, or outdoors. Following exposure, the tubes were loaded with 5 mL of hyperglycemic leukocyte-reduced bank blood, with glucose levels in excess of 300 milligrams per deciliter (mg/dL), artificially spiked with EtOH to a target concentration of 0.08 grams/100 milliliters (gm%), and placed into one of the three storage conditions for two weeks: refrigerated at a temperature of 2 to 8 degrees Celsius (℃), room temperature at 20 to 25 ℃, and in a vehicle trunk with an outdoor temperature of, on average, 24.8 to 31.6 ℃. Upon completion of the two-week storage period, all samples were stored in a refrigerated storage vault prior to analysis to simulate real-world conditions. Three BAC measurements were performed on the samples: an initial baseline measurement before storage, a second analysis following the two-week storage period, and a final analysis after six and a half months of refrigerated storage. The results of this study indicate that there is no significant effect on BAC levels when using a 10 mL BD Vacutainer® tube past its expiration date. No de novo EtOH synthesis was detected; all ethanol-negative samples yielded non-detectable BAC measurements throughout the study. No significant differences in BAC levels were observed among the various simulated collection environments. The most significant decrease in EtOH concentration occurred in samples stored in the vehicle trunk, followed by those stored at room temperature; refrigerated samples showed the smallest decrease."]},{"key":"dc:title","label":"Title","values":["Expiration, collection, and storage: a multi-factor investigation of blood alcohol concentration"]}]}],"canonical_facts":{"dc:contributor.advisor":["Wareing, Celeste M"],"dc:creator":["Woolley, Roth Cook Sinclair"],"dc:date.accessioned":["2026-10-23T15:48:46Z"],"dc:date.available":["2026-10-23T15:48:46Z"],"dc:date.issued":["2026"],"dc:date.updated":["2026-08-26T16:17:53Z"],"dc:description":["2026"],"dc:description.abstract":["A frequently encountered argument in impaired driving cases involving blood alcohol concentrations (BAC) is that ethanol (EtOH) levels may have been produced post-collection via microbial fermentation. Prior studies have independently refuted the effects of factors such as tube expiration status, collection method, and blood glucose level. This study, however, assessed the validity of these concerns collectively utilizing standard-issue 10 milliliter (mL) BD Vacutainer® Grey-Top Tubes containing 100 milligrams (mg) of sodium fluoride and 20 mg of potassium oxalate. Expired and unexpired blood collection tubes were compared under a variety of environmental conditions intended to simulate common collection scenarios. These scenarios involved following the recommended collection technique and leaving the tubes uncapped for 1 hour on a laboratory bench, in a restroom, or outdoors. Following exposure, the tubes were loaded with 5 mL of hyperglycemic leukocyte-reduced bank blood, with glucose levels in excess of 300 milligrams per deciliter (mg/dL), artificially spiked with EtOH to a target concentration of 0.08 grams/100 milliliters (gm%), and placed into one of the three storage conditions for two weeks: refrigerated at a temperature of 2 to 8 degrees Celsius (℃), room temperature at 20 to 25 ℃, and in a vehicle trunk with an outdoor temperature of, on average, 24.8 to 31.6 ℃. Upon completion of the two-week storage period, all samples were stored in a refrigerated storage vault prior to analysis to simulate real-world conditions. Three BAC measurements were performed on the samples: an initial baseline measurement before storage, a second analysis following the two-week storage period, and a final analysis after six and a half months of refrigerated storage. The results of this study indicate that there is no significant effect on BAC levels when using a 10 mL BD Vacutainer® tube past its expiration date. No de novo EtOH synthesis was detected; all ethanol-negative samples yielded non-detectable BAC measurements throughout the study. No significant differences in BAC levels were observed among the various simulated collection environments. The most significant decrease in EtOH concentration occurred in samples stored in the vehicle trunk, followed by those stored at room temperature; refrigerated samples showed the smallest decrease."],"dc:identifier.uri":["https://hdl.handle.net/2144/53797"],"dc:language.iso":["en_US"],"dc:subject":["Toxicology","Forensic sciences","Blood alcohol testing","Ethanol","Glucose"],"dc:title":["Expiration, collection, and storage: a multi-factor investigation of blood alcohol concentration"],"dc:type":["Thesis/Dissertation"],"thesis:degree_discipline":["Biomedical Forensic Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Boston University"]},"updated_at":"2026-11-18T19:23:57Z"}